Searched for: +
(1 - 20 of 57)

Pages

document
Leinders, S.M. (author), Westerveld, W.J. (author), Pozo, J. (author), Neer, P.L.M.J. (author), Snyder, B. (author), O'Brien, P. (author), Urbach, H.P. (author), de Jong, N. (author), Verweij, M.D. (author)
With the increasing use of ultrasonography, especially in medical imaging, novel fabrication techniques together with novel sensor designs are needed to meet the requirements for future applications like three-dimensional intercardiac and intravascular imaging. These applications require arrays of many small elements to selectively record the...
journal article 2015
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Sabbadini, A. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Current ultrasonic clamp-on flow meters consist of a pair of single-element transducers that are carefully positioned before use. This positioning process consists of manually finding the distance between the transducer elements, along the pipe axis, for which maximum signal-to-noise ratio (SNR) is achieved. This distance depends on the sound...
journal article 2021
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe...
journal article 2022
document
Mozaffarzadeh, M. (author), Verweij, M.D. (author), de Jong, N. (author), Renaud, G.G.J. (author)
While transcranial ultrasound imaging is a promising diagnostic modality, it is still hindered due to phase aberration and multiple scattering caused by the skull. In this paper, we compare near-field phase-screen modeling (PS) to a geometry-based phase aberration correction technique (GB) when an ultrafast imaging sequence (five plane waves...
journal article 2022
document
Wei, Luxi (author), Wahyulaksana, G. (author), Meijlink, Bram (author), Ramalli, Alessandro (author), Noothout, E.C. (author), Verweij, M.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter...
journal article 2021
document
Waasdorp, R. (author), Mugge, W. (author), Vos, H.J. (author), De Groot, Jurriaan H. (author), Verweij, M.D. (author), de Jong, N. (author), Schouten, A.C. (author), Daeichin, V. (author)
Skeletal muscles generate force, enabling movement through a series of fast electro-mechanical activations coordinated by the central nervous system. Understanding the underlying mechanism of such fast muscle dynamics is essential in neuromuscular diagnostics, rehabilitation medicine and sports biomechanics. The unique combination of...
journal article 2021
document
Sabbadini, A. (author), Caenen, A.F.M. (author), Vos, H.J. (author), de Jong, N. (author), Verweij, M.D. (author)
Shear Wave Elastography (SWE) has been proposed to investigate cardiac health by non-invasively monitoring tissue stiffness. Previous work has shown that the plate-like geometry of the Interventricular Septum (IVS) may result in a dispersion similar to Lamb waves, complicating the link between shear wave speed and cardiac stiffness. However, the...
journal article 2019
document
Mozaffarzadeh, M. (author), Minonzio, C.G. (author), de Jong, N. (author), Verweij, M.D. (author), Hemm, Simone (author), Renaud, G.G.J. (author), Daeichin, V. (author)
In the above article [1], we mentioned that the superposition of the different symmetric (S) modes in the frequencywavenumber (f-k) domain results in a high-intensity region where its slope corresponds to the longitudinal wave speed in the slab. However, we have recently understood that this highintensity region belongs to the propagation of...
journal article 2020
document
Beekers, D.I. (author), Vegter, Merel (author), Lattwein, Kirby R. (author), Mastik, Frits (author), Beurskens, Robert (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Kooiman, Klazina (author)
Ultrasound insonification of microbubbles can locally increase vascular permeability to enhance drug delivery. To control and optimize the therapeutic potential, we need to better understand the underlying biological mechanisms of the drug delivery pathways. The aim of this in vitro study was to elucidate the microbubble-endothelial cell...
journal article 2020
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Acoustic wave propagation in ultrasonic flow measurements is typically assumed to be linear and reciprocal. However, if the transmitting transducer generates a sufficiently high pressure, nonlinear wave propagation effects become significant. In flow measurements, this would translate into more information to estimate the flow and therefore a...
journal article 2021
document
Sabbadini, A. (author), Caenen, A.F.M. (author), Keijzer, L.B.H. (author), van Neer, P.L.M.J. (author), Vos, H.J. (author), de Jong, N. (author), Verweij, M.D. (author)
Shear wave elastography (SWE) has the potential to determine cardiac tissue stiffness from non-invasive shear wave speed measurements, important, e.g., for predicting heart failure. Previous studies showed that waves traveling in the interventricular septum (IVS) may display Lamb-like dispersive behaviour, introducing a thickness-frequency...
journal article 2021
document
Mozaffarzadeh, M. (author), Moore, Colman (author), Golmoghani, Erfan Barzegar (author), Mantri, Yash (author), Hariri, Ali (author), Jorns, Alec (author), Fu, Lei (author), Verweij, M.D. (author), de Jong, N. (author)
Simultaneous visualization of the teeth and periodontium is of significant clinical interest for image-based monitoring of periodontal health. We recently reported the application of a dual-modality photoacoustic-ultrasound (PA-US) imaging system for resolving periodontal anatomy and periodontal pocket depths in humans. This work utilized a...
journal article 2021
document
Collado Lara, G. (author), Heymans, Sophie V. (author), Rovituso, M. (author), Carlier, Bram (author), Toumia, Yosra (author), Verweij, M.D. (author), Vos, H.J. (author), de Jong, N. (author), Daeichin, V. (author)
The potential of proton therapy to improve the conformity of the delivered dose to the tumor volume is currently limited by range uncertainties. Injectable superheated nanodroplets have recently been proposed for ultrasound-based in vivo range verification, as these vaporize into echogenic microbubbles on proton irradiation. In previous...
journal article 2021
document
Spiekhout, Sander (author), Voorneveld, J.D. (author), Van Elburg, Benjamin (author), Renaud, G.G.J. (author), Segers, Tim (author), Lajoinie, Guillaume P.R. (author), Versluis, Michel (author), Verweij, M.D. (author), de Jong, N. (author), Bosch, Johannes G. (author)
Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 μm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera"(AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation. In this article,...
journal article 2022
document
Hakakzadeh, Soheil (author), Mozaffarzadeh, M. (author), Mostafavi, S.. (author), Kavehvash, Zahra (author), Rajendran, Praveenbalaji (author), Verweij, M.D. (author), de Jong, N. (author), Pramanik, Manojit (author)
In photoacoustic tomography (PAT) systems, the tangential resolution decreases due to the finite size of the transducer as the off-center distance increases. To address this problem, we propose a multi-angle detection approach in which the transducer used for data acquisition rotates around its center (with specific angles) as well as around...
journal article 2022
document
Ossenkoppele, B.W. (author), Luijten, Ben (author), Bera, Deep (author), de Jong, N. (author), Verweij, M.A. (author), van Sloun, Ruud J.G. (author)
There is an increased desire for miniature ultrasound probes with small apertures to provide volumetric images at high frame rates for in-body applications. Satisfying these increased requirements makes simultaneous achievement of a good lateral resolution a challenge. As micro-beamforming is often employed to reduce data rate and cable count...
journal article 2023
document
Li, H. (author), Li, X. (author), Collado Lara, G. (author), Lattwein, K.R. (author), Mastik, Frits (author), Beurskens, Robert (author), van der Steen, A.F.W. (author), Verweij, M.A. (author), de Jong, N. (author), Kooiman, Klazina (author)
Ultrasound contrast-mediated medical imaging and therapy both rely on the dynamics of micron- and nanometer-sized ultrasound cavitation nuclei, such as phospholipid-coated microbubbles and phase-change droplets. Ultrasound cavitation nuclei respond non-linearly to ultrasound on a nanosecond time scale that necessitates the use of ultra-high...
journal article 2023
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Kim, Taehoon (author), Fool, F. (author), Simoes dos Santos, D. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a...
journal article 2021
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a compact analog front-end (AFE) circuit for ultrasound receivers with linear-in-dB continuous gain control for time-gain compensation (TGC). The AFE consists of two variable-gain stages, both of which employ a novel complementary current-steering network (CCSN) as the interpolator to realize continuously variable gain....
journal article 2022
Searched for: +
(1 - 20 of 57)

Pages