Searched for: +
(1 - 5 of 5)
document
Wu, D. (author), Zhang, R. (author), Pore, Ameya (author), Ha, Xuan Thao (author), Li, Z. (author), Herrera, Fernando (author), Kowalczyk, Wojtek (author), De Momi, Elena (author), Dankelman, J. (author), Kober, J. (author)
Minimally Invasive Procedures (MIPs) emerged as an alternative to more invasive surgical approaches, offering patient benefits such as smaller incisions, less pain, and shorter hospital stay. In one class of MIPs, where natural body lumens or small incisions are used to access deeper anatomical locations, Flexible Surgical and Interventional...
review 2024
document
Ha, Xuan Thao (author), Wu, D. (author), Ourak, Mouloud (author), Borghesan, Gianni (author), Dankelman, J. (author), Menciassi, Arianna (author), Poorten, Emmanuel Vander (author)
In this article, a deep learning method for the shape sensing of continuum robots based on multicore fiber bragg grating (FBG) fiber is introduced. The proposed method, based on an artificial neural network (ANN), differs from traditional approaches, where accurate shape reconstruction requires a tedious characterization of many...
journal article 2023
document
Wu, D. (author), Ha, Xuan Thao (author), Zhang, Yao (author), Ourak, Mouloud (author), Borghesan, Gianni (author), Niu, Kenan (author), Trauzettel, F. (author), Dankelman, J. (author), Menciassi, Arianna (author), Poorten, Emmanuel Vander (author)
In cardiovascular interventions, when steering catheters and especially robotic catheters, great care should be paid to prevent applying too large forces on the vessel walls as this could dislodge calcifications, induce scars or even cause perforation. To address this challenge, this paper presents a novel compliant motion control algorithm...
journal article 2022
document
Wu, D. (author), Zhang, Yao (author), Ourak, Mouloud (author), Ha, Xuan Thao (author), Niu, Kenan (author), Dankelman, J. (author), Poorten, Emmanuel Vander (author)
Precise control of robotic catheters remains challenging in interventions. Inherent non-linearities such as hysteresis and external disturbances such as blood flow or contact with the vessel walls have a large impact on the reachable positioning precision. As inaccurate positioning of the catheter tip could lead to tissue damage, controllers...
conference paper 2022
document
Wu, Di (author), Zhang, Yao (author), Ourak, Mouloud (author), Niu, Kenan (author), Dankelman, J. (author), Vander Poorten, Emmanuel B. (author)
Catheters are increasingly being used to tackle problems in the cardiovascular system. However, positioning precision of the catheter tip is negatively affected by hysteresis. To ensure tissue damage due to imprecise positioning is avoided, hysteresis is to be understood and compensated for. This work investigates the feasibility to model...
journal article 2021
Searched for: +
(1 - 5 of 5)