- document
-
Belletti, B. (author), Damoni, C. (author), Hendriks, M.A.N. (author), Den Uijl, J.A. (author)According to the new fib Model Code 2010 the design shear resistance of a reinforced concrete (RC) structure can be evaluated through analytical and numerical calculation methods that fall into four different levels of approximations; the complexity and the accuracy of the calculated shear resistance increases with increasing the level of...conference paper 2013