van Willigen, D.M. (author), Neer, Paul L.M.J. van (author), Massaad Mouawad, J.M. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
Transit-time ultrasonic flow meters are widely used in industry to measure fluid flow. In practice ultrasonic flow meters either show a zero-flow error or suffer from a significant random error due to a limited signal-to-noise ratio, requiring a significant amount of averaging to achieve good precision. This work presents a method that minimizes...
journal article 2020
document
Leinders, S.M. (author), Westerveld, W.J. (author), Pozo, J. (author), Neer, P.L.M.J. (author), Snyder, B. (author), O'Brien, P. (author), Urbach, H.P. (author), de Jong, N. (author), Verweij, M.D. (author)
With the increasing use of ultrasonography, especially in medical imaging, novel fabrication techniques together with novel sensor designs are needed to meet the requirements for future applications like three-dimensional intercardiac and intravascular imaging. These applications require arrays of many small elements to selectively record the...