Searched for: +
(41 - 53 of 53)

Pages

document
Voorneveld, J.D. (author), Engelhard, S. (author), Vos, H.J. (author), Reijnen, M. (author), Gijsen, F.J.H. (author), Versluis, M. (author), Jebbink, E. Groot (author), de Jong, N. (author), Bosch, J. G. (author)
Treatment of abdominal aortic (AA) aneurysms and stenotic lesions may be improved by analyzing their associated blood flow patterns. Angle-independent blood flow patterns in the AA can be obtained by combining echo-particle image velocimetry (ePIV) with high frame rate contrast-enhanced ultrasonography. However, ePIV performance is affected...
journal article 2018
document
de Jong, M. (author), Mavridis, P. (author), Aroyo, Lora (author), Bozzon, A. (author), Vos, Jesse de (author), Oomen, Johan (author), Dimitrova, Antoaneta (author), Badenoch, Alec (author)
In this project we explore the presence of ambiguity in textual and visual media and its influence on accurately understanding and<br/>capturing bias in news. We study this topic in the context of supporting<br/>media scholars and social scientists in their media analysis. Our focus<br/>lies on racial and gender bias as well as framing and the...
conference paper 2018
document
Kang, E. (author), Ding, Q. (author), Shabanimotlagh, M. (author), Kruizinga, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, J.W. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) designed for 3-D ultrasonic imaging of the carotid artery. This application calls for an array of thousands of ultrasonic transducer elements, far exceeding the number of channels of conventional imaging systems. The 3.6 x 6.8 mm&amp;#x00B2; ASIC...
journal article 2018
document
Bera, D. (author), Van Den Adel, Franc (author), Radeljic-Jakic, Nikola (author), Lippe, Boris (author), Soozande, M. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Kruizinga, P. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), Bosch, Johan G. (author), de Jong, N. (author)
We describe a 3-D multiline parallel beamforming scheme for real-time volumetric ultrasound imaging using a prototype matrix transesophageal echocardiography probe with diagonally diced elements and separated transmit and receive arrays. The elements in the smaller rectangular transmit array are directly wired to the ultrasound system. The...
journal article 2018
document
Daeichin, V. (author), Bera, D. (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Chen, Z. (author), Chen, C. (author), Noothout, E.C. (author), Vos, H.J. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a...
journal article 2018
document
Bera, D. (author), Raghunathan, S.B. (author), Chen, C. (author), Chen, Z. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, J.G. (author)
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (&gt;200 Hz). To address these issues, we have recently...
journal article 2018
document
Mavridis, P. (author), de Jong, M. (author), Aroyo, Lora (author), Bozzon, A. (author), Vos, Jesse de (author), Oomen, Johan (author), Dimitrova, Antoaneta (author), Badenoch, Alec (author)
Bias is inevitable and inherent in any form of communication. News often appear biased to citizens with dierent political orientations, and understood dierently by news media scholars and the broader public. In this paper we advocate the need for accurate methods for bias identication in video news item, to enable rich analytics capabilities in...
conference paper 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Noothout, E.C. (author), Chang, Z.Y. (author), Tan, M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a front-end application-specified integrated circuit (ASIC) integrated with a 2-D PZT matrix transducer that enables in-probe digitization with acceptable power dissipation for the next-generation endoscopic and catheter-based 3-D ultrasound imaging systems. To achieve power-efficient massively parallel analog-to-digital...
journal article 2018
document
Fool, F. (author), de Wit, J. (author), Vos, H.J. (author), Bera, D. (author), de Jong, N. (author), Verweij, M.D. (author)
The huge amount of data that needs to be transferred between probe and imaging system becomes a major issue when the data transfer capacity is limited, e.g. in handheld systems, wireless probes and miniaturized probes. The amount of data can be significantly reduced by using two-stage beamforming. The first stage consists of a fixed focus...
conference paper 2018
document
Strachinaru, Mihai (author), Bosch, Johan G. (author), van Dalen, Bas M. (author), van Gils, Lennart (author), van der Steen, A.F.W. (author), de Jong, N. (author), Geleijnse, Marcel L. (author), Vos, H.J. (author)
The propagation velocity of shear waves relates to tissue stiffness. We prove that a regular clinical cardiac ultrasound system can determine shear wave velocity with a conventional unmodified tissue Doppler imaging (TDI) application. The investigation was performed on five tissue phantoms with different stiffness using a research platform...
journal article 2017
document
Vos, H.J. (author), van Dalen, Bas M. (author), Heinonen, Ilkka (author), Bosch, Johan G. (author), Sorop, Oana (author), Duncker, Dirk J. (author), van der Steen, A.F.W. (author), de Jong, N. (author)
Cardiac muscle stiffness can potentially be estimated non-invasively with shear wave elastography. Shear waves are present on the septal wall after mitral and aortic valve closure, thus providing an opportunity to assess stiffness in early systole and early diastole. We report on the shear wave recordings of 22 minipigs with high-frame-rate...
journal article 2017
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Prins, Christian (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm<sup>2</sup> ASIC, implemented...
journal article 2017
document
Kooiman, Klazina (author), van Rooij, Tom (author), Qin, Bin (author), Mastik, Frits (author), Vos, H.J. (author), Versluis, Michel (author), Klibanov, Alexander L. (author), de Jong, N. (author), Villanueva, Flordeliza S. (author), Chen, Xucai (author)
Acoustic behavior of lipid-coated microbubbles has been widely studied, which has led to several numerical microbubble dynamics models that incorporate lipid coating behavior, such as buckling and rupture. In this study we investigated the relationship between micro-bubble acoustic and lipid coating behavior on a nanosecond scale by using...
journal article 2017
Searched for: +
(41 - 53 of 53)

Pages