Searched for: author%3A%22Vogel%2C+J.G.%22
(1 - 9 of 9)
document
el Mansouri, B. (author), Middelburg, L.M. (author), Poelma, René H. (author), Zhang, Kouchi (author), van Zeijl, H.W. (author), Wei, J. (author), Jiang, H. (author), Vogel, J.G. (author), van Driel, W.D. (author)
Commercially available gravimeters and seismometers can be used for measuring Earth’s acceleration at resolution levels in the order of ng∕Hz (where g represents earth’s gravity) but they are typically high-cost and bulky. In this work the design of a bulk micromachined MEMS device exploiting non-linear buckling behaviour is described, aiming...
journal article 2019
document
van de Ven, Oscar S. (author), Vogel, J.G. (author), Xia, Sha (author), Spronck, J.W. (author), Nihtianova, S. (author)
High-precision positioning often requires high speed and high resolution displacement measurements in order to compensate for the small vibrations of critical components. The displacement sensor must be precise and stable over a long period of time to avoid expensive recalibration. This requires tight mounting tolerances, which are especially...
journal article 2018
document
Jiang, H. (author), Amani, Samira (author), Vogel, J.G. (author), Heidary Shalmany, S. (author), Nihtianova, S. (author)
This paper describes a high-performance Capacitance-to-Digital Converter (CDC) for sub-nm displacement sensing with an electrically floating target. Intended to be integrated into a displacement sensor probe, the CDC consumes only 560μW. It achieves 98.5dB SNR in a 1ms conversion time, which is 34 times more energy-efficient than the prior...
conference paper 2018
document
Chaturvedi, V. (author), Vogel, J.G. (author), Makinwa, K.A.A. (author), Nihtianova, S. (author)
This paper presents an eddy-current sensor (ECS) interface intended for sub-nanometer (sub-nm) displacement sensing in hi-tech applications. The interface employs a 126-MHz excitation frequency to mitigate the skin effect, and achieve high resolution and stability. An efficient on-chip sensor offset compensation scheme is introduced which...
journal article 2018
document
Vogel, J.G. (author), Chaturvedi, V. (author), Nihtianova, S. (author)
Unlike capacitive displacement sensors, Eddy-Current Displacement Sensors (ECDSs) possess an inherently low sensitivity to environmental conditions, such as the humidity of the ambient air. By elevating the excitation frequency it is possible to mitigate their major limitations regarding stability and resolution, making them of interest for high...
conference paper 2017
document
Jiang, H. (author), Vogel, J.G. (author), Nihtianova, S. (author)
This paper presents a direct digital converter for Wheatstone bridge sensors, which is realized with commercial off-the-shelf components. The power efficiency of the readout is enhanced by embedding the bridge sensor in a second-order continuous-time sigma-delta modulator (CTDeltaSigmaM). By directly digitizing the output signal of a Wheatstone...
journal article 2017
document
Vogel, J.G. (author)
In wafer scanners - the machines that define the details of electronic chips - there is a need for highly accurate deformation measurements of the machine components during the chip manufacturing process.<br/>This thesis develops an estimation methodology, based on shape fitting principles, that aims at a low estimation error and addresses the...
doctoral thesis 2016
document
Chaturvedi, V. (author), Vogel, J.G. (author), Nihtianova, S. (author)
The suppression efficiency of the correlated noise and drift of self-oscillating front-end circuit in a pseudo-differential eddy-current displacement sensor (ECDS) is investigated using COMSOL and MATLAB. The transfer characteristic of the sensor coil, excited at 200 MHz, is obtained through a FE model in COMSOL. The characteristic is linearized...
journal article 2016
document
Loeve, A.J. (author), Van de Ven, O.S. (author), Vogel, J.G. (author), Breedveld, P. (author), Dankelmann, J. (author)
In order to fully benefit from the functionalities of flexible endoscopes in surgery a simple shaft-guide that can be used to support the flexible endoscope shaft is required. Such a shaft-guide must be flexible during insertion into the human body and rigidified when properly positioned to support the flexible endoscope shaft. A shaft-guide...
journal article 2010
Searched for: author%3A%22Vogel%2C+J.G.%22
(1 - 9 of 9)