document
Noom, J. (author), Smith, C.S. (author), Verbiest, G.J. (author), Katan, A.J. (author), Soloviev, O.A. (author), Verhaegen, M.H.G. (author)
We propose to use the State Estimation by Sum-of-Norms Regularisation (STATESON-)algorithm for recovering the tip-sample interaction in high-speed tapping mode atomic force microscopy (AFM). This approach enables accurate sample height estimation for each independent cantilever oscillation period, provided that the tip-sample interaction...
journal article 2023
document
Hung, S. (author), Llobet Rosell, Arnau (author), Jurriens, Daphne (author), Soloviev, O.A. (author), Kapitein, Lukas C. (author), Grußmayer, K.S. (author), Neukomm, Lukas J. (author), Verhaegen, M.H.G. (author), Smith, C.S. (author)
Single-molecule localization microscopy (SMLM) enables the high-resolution visualization of organelle structures and the precise localization of individual proteins. However, the expected resolution is not achieved in tissue as the imaging conditions deteriorate. Sample-induced aberrations distort the point spread function (PSF), and high...
journal article 2022
document
Noom, J. (author), Soloviev, O.A. (author), Smith, C.S. (author), Nguyen, Hieu Thao (author), Verhaegen, M.H.G. (author)
We demonstrate a novel closed-loop input design technique on the detection of particles in an imaging system such as a fluorescence microscope. The probability of misdiagnosis is minimized while constraining the input energy such that for instance phototoxicity is reduced. The key novelty of the closed-loop design is that each next input is...
conference paper 2022
document
Noom, J. (author), Soloviev, O.A. (author), Smith, C.S. (author), Verhaegen, M.H.G. (author)
Some applications require high level of image-based classification certainty while keeping the total illumination energy as low as possible. Examples are minimally invasive visual inspection in Industry 4.0, and medical imaging systems such as computed tomography, in which the radiation dose should be kept “as low as is reasonably achievable”...
conference paper 2022
document
Hung, S. (author), Cnossen, J.P. (author), Fan, D. (author), Siemons, Marijn (author), Jurriens, Daphne (author), Grußmayer, K.S. (author), Soloviev, O.A. (author), Kapitein, Lukas C. (author), Smith, C.S. (author)
High-NA light sheet illumination can improve the resolution of single-molecule localization microscopy (SMLM) by reducing the background fluorescence. These approaches currently require custom-made sample holders or additional specialized objectives, which makes the sample mounting or the optical system complex and therefore reduces the...
journal article 2022
document
Pozzi, P. (author), Smith, C.S. (author), Carroll, E.C.M. (author), Wilding, D. (author), Soloviev, O.A. (author), Booth, Martin (author), Vdovin, Gleb (author), Verhaegen, M.H.G. (author)
Inhomogeneities in the refractive index of a biological microscopy sample can introduce phase aberrations, severely impairing the quality of images. Adaptive optics can be employed to correct for phase aberrations and improve image quality. However, conventional adaptive optics can only correct a single phase aberration for the whole field of...
journal article 2020