Searched for: collection%253Air
(1 - 10 of 10)
document
Guo, P. (author), Fool, F. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a low-power and small-area transceiver application-specific integrated circuit (ASIC) for 3-D trans-fontanelle ultrasonography. A novel micro-beamforming receiver architecture that employs current-mode summation and boxcar integration is used to realize delay-and-sum on an N -element sub-array using N× fewer capacitive...
journal article 2023
document
Wei, Luxi (author), Boni, Enrico (author), Ramalli, Alessandro (author), Fool, F. (author), Noothout, E.C. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Tortoli, Piero (author), de Jong, N. (author), Vos, H.J. (author)
Two-dimensional (2-D) arrays offer volumetric imaging capabilities without the need for probe translation or rotation. A sparse array with elements seeded in a tapering spiral pattern enables one-to-one connection to an ultrasound machine, thus allowing flexible transmission and reception strategies. To test the concept of sparse spiral array...
journal article 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Kim, Taehoon (author), Noothout, E.C. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), De Jona, Nico (author)
Over the past decades, ultrasound imaging has made considerable progress based on the advancement of imaging systems as well as transducer technology. With the need for advanced transducer arrays with complex designs and technical requirements, there is also a need for suitable tools to characterize such transducers. However, despite the...
conference paper 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Mozaffarzadeh, M. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Kim, T. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for...
journal article 2022
document
Guo, P. (author), Fool, F. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
The integration of 2D ultrasonic transducer arrays and pitch-matched ASICs has enabled the realization of various 3D ultrasound imaging devices in recent years [1]-[3]. As applications such as 3D intravascular ultrasonography, intra-cardiac echocardiography, and trans-fontanelle ultrasonography call for miniaturization and improved spatial...
conference paper 2022
document
Kim, Taehoon (author), Fool, F. (author), Simoes dos Santos, D. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a...
journal article 2021
document
Simoes dos Santos, D. (author), Fool, F. (author), Kim, Taehoon (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Over the past decades, real-time three-dimensional (3D) medical ultrasound has attracted much attention since it enables clinicians to diagnose more accurately. This calls for ultrasound matrix transducers with a large number of elements, which can be interfaced with an application-specific integrated circuit (ASIC) for data reduction. An...
conference paper 2021
document
Mozaffarzadeh, M. (author), Soozande, M. (author), Fool, F. (author), Pertijs, M.A.P. (author), Vos, H.J. (author), Verweij, M.D. (author), Bosch, Johan G. (author), de Jong, N. (author)
Recently, we realized a prototype matrix transducer consisting of 48 rows of 80 elements on top of a tiled set of Application Specific Integrated Circuits (ASICs) implementing a row-level control connecting one transmit/receive channel to an arbitrary subset of elements per row. A fully sampled array data acquisition is implemented by a...
journal article 2020
document
Fool, F. (author), Vos, H.J. (author), Shabanimotlagh, M. (author), Soozande, M. (author), Mozaffarzadeh, M. (author), Kim, T. (author), Kang, E. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
To accurately investigate the state of the carotid artery by the local haemodynamics and motion of the plaque using ultrasound, high-frame rate volumetric imaging is necessary. We have specifically designed a matrix array for this purpose. In this proceeding we will focus on imaging a volumetric flow profile using this matrix. For this...
conference paper 2019
document
Fool, F. (author), de Wit, J. (author), Vos, H.J. (author), Bera, D. (author), de Jong, N. (author), Verweij, M.D. (author)
The huge amount of data that needs to be transferred between probe and imaging system becomes a major issue when the data transfer capacity is limited, e.g. in handheld systems, wireless probes and miniaturized probes. The amount of data can be significantly reduced by using two-stage beamforming. The first stage consists of a fixed focus...
conference paper 2018
Searched for: collection%253Air
(1 - 10 of 10)