document
Middelburg, L.M. (author), Ghaderi, M. (author), Visser, J.H. (author), Wolffenbuttel, R.F. (author)
The resistive particulate matter sensor is a simple device that transduces the presence of soot through impedance change across inter-digital electrodes (IDEs). We investigate the information provided by impedance spectroscopy over the frequency range from 100 Hz to 10 kHz for two purposes. The first is to investigate the opportunities for an...
journal article 2020
document
Middelburg, L.M. (author), Ghaderi, Mohammadamir (author), Bilby, David (author), Visser, J.H. (author), Zhang, Kouchi (author), Wolffenbuttel, R.F. (author)
Impedance spectroscopy in the frequency range 100 Hz to 10 kHz has been applied to the Inter-Digitated Electrode (IDE) structure that is conventionally operated as a resistive sensor for the measurement of Particulate Matter (PM). The measurement of both the in-phase (resistive) and out-of-phase (capacitive) components of the impedance over this...