Searched for: collection%253Air
(1 - 6 of 6)
document
Wang, L. (author), Qin, Z. (author), Beloqui Larumbe, L. (author), Bauer, P. (author)
To accurately simulate the harmonic emission of EV DC fast chargers (DCFCs) and the harmonic voltage of the power grid to which the chargers are connected, a small time-step, i.e., typically smaller than 10μs, is required. However, for harmonic assessment, a long timescale, typically a day, is required. A conflict between accuracy and time...
conference paper 2021
document
Vree, D. (author), Beloqui Larumbe, L. (author), Qin, Z. (author), Bauer, P. (author), Ummels, B.C. (author)
In this decade, a significant amount of additional wind and solar power will be integrated in the Dutch high voltage grid. The 383 MW nearshore Wind Park Fryslân is foressen to be connected to the Dutch 110kV grid in 2020 through two 55km cable circuits. To quantify the risks of exceeding emission levels for both the TSO and the wind farm...
conference paper 2020
document
Beloqui Larumbe, L. (author), Qin, Z. (author), Bauer, P. (author)
A voltage imbalance at the AC terminals of a three-phase inverter creates a ripple in the power signal on the DC side. In order to minimize this ripple, several techniques can be applied, in which a double Synchronous Reference Frame (SRF) current control structure is very typical. In this approach, both the positive and negative sequence...
conference paper 2020
document
Shekhar, A. (author), Beloqui Larumbe, L. (author), Soeiro, Thiago B. (author), Wu, Y. (author), Bauer, P. (author)
There is an increasing focus on integrating flexible dc links for bulk power routing in medium voltage distribution grids. In such applications, the ac-dc Modular Multilevel Converter (MMC) devised for medium voltage and high-power ratings can be an interesting choice. This paper highlights some less explored design trade-offs arising due to...
conference paper 2019
document
Beloqui Larumbe, L. (author), Qin, Z. (author), Bauer, P. (author)
In this paper, the output impedance of a three-phase inverter based on a dual current control (also called double synchronous reference frame current control) is modelled, which includes: the current loop gain, the control delay, and the Phase-<br/>Locked Loop (PLL). The impact of these parameters on the impedance is then analysed by a...
conference paper 2019
document
Beloqui Larumbe, L. (author), Qin, Z. (author), Bauer, P. (author)
Several efforts are being done nowadays to improve the modelling of Wind Turbine Systems (WTSs) for harmonic analysis in Offshore Wind Power Plants (OWPPs). Due to the high influence of the different control structures in the Power Electronic Converters (PECs) on the dynamic response of a WTS, each structure needs to be modelled specifically....
conference paper 2018
Searched for: collection%253Air
(1 - 6 of 6)