Searched for: collection%253Air
(81 - 100 of 338)

Pages

document
Li, T. (author), Vos, J.V. (author), Erkin, Z. (author)
In January 2017, a truck crossed the border between Spain and France for the first time using an e-CMR: An electronic version of the primary transport document required for inter-European logistics. Since that crossing, researchers and logistic organizations have proposed a large number of ideas to further digitize Europe’s supply chain. Many of...
conference paper 2022
document
Wei, Luxi (author), Boni, Enrico (author), Ramalli, Alessandro (author), Fool, F. (author), Noothout, E.C. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Tortoli, Piero (author), de Jong, N. (author), Vos, H.J. (author)
Two-dimensional (2-D) arrays offer volumetric imaging capabilities without the need for probe translation or rotation. A sparse array with elements seeded in a tapering spiral pattern enables one-to-one connection to an ultrasound machine, thus allowing flexible transmission and reception strategies. To test the concept of sparse spiral array...
journal article 2022
document
Soozande, Mehdi (author), Ossenkoppele, B.W. (author), Hopf, Y.M. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author), Vos, H.J. (author), Bosch, Johan G. (author)
Atrial fibrillation (AF) is the most common cardiac arrhythmia and is normally treated by RF ablation. Intracardiac echography (ICE) is widely employed during RF ablation procedures to guide the electrophysiologist in navigating the ablation catheter, although only 2-D probes are currently clinically used. A 3-D ICE catheter would not only...
journal article 2022
document
Nagtegaal, M.A. (author), Hartsema, Emiel (author), Koolstra, Kirsten (author), Vos, F.M. (author)
Purpose: To develop an efficient algorithm for multicomponent MR fingerprinting (MC-MRF) reconstructions directly from highly undersampled data without making prior assumptions about tissue relaxation times and expected number of tissues. Methods: The proposed method reconstructs MC-MRF maps from highly undersampled data by iteratively...
journal article 2022
document
Kuschnerus, M. (author), Lindenbergh, R.C. (author), Lodder, Q.J. (author), Brand, E. (author), Vos, S.E. (author)
Coastal areas world wide are highly dynamic areas, subject to continuous deformation processes. Both natural and anthropogenic processes constantly cause changes at various spatial scales. Sandy beaches in the Netherlands fall under a regulation, according to which moving sand is permitted, if the volume change remains below a certain...
journal article 2022
document
Caspers, M.P.T. (author), Krishnaswamy Usha, A. (author), Vos, G.M. (author)
Let G be a locally compact unimodular group, and let φ be some function of n variables on G. To such a φ, one can associate a multilinear Fourier multiplier, which acts on some n-fold product of the noncommutative L <sub>p</sub>-spaces of the group von Neumann algebra. One may also define an associated Schur multiplier, which acts on an n...
journal article 2022
document
Deurvorst, F.R. (author), Collado Lara, G. (author), Matalliotakis, A. (author), Vos, H.J. (author), de Jong, N. (author), Daeichin, V. (author), Verweij, M.D. (author)
An in vivo range verification technology for proton beam cancer therapy, preferably in real-time and with submillimeter resolution, is desired to reduce the present uncertainty in dose localization. Acoustical imaging technologies exploiting possible local interactions between protons and microbubbles or nanodroplets might be an interesting...
journal article 2022
document
Bouwknegt, J. (author), Vos, A.M. (author), Ortiz Merino, R.A. (author), van Cuylenburg, Daphne C. (author), Luttik, M.A.H. (author), Pronk, J.T. (author)
Analysis of predicted fungal proteomes revealed a large family of sequences that showed similarity to the Saccharomyces cerevisiae Class-I dihydroorotate dehydrogenase Ura1, which supports synthesis of pyrimidines under aerobic and anaerobic conditions. However, expression of codon-optimised representatives of this gene family, from the...
journal article 2022
document
Ossenkoppele, B.W. (author), Wei, Luxi (author), Luijten, Ben (author), Vos, H.J. (author), de Jong, N. (author), Van Sloun, Ruud J.G. (author), Verweij, M.D. (author)
3-D contrast enhanced ultrasound enables better visualization of inherently 3-D vascular geometries compared to an intersecting plane. Additionally, it would allow the application of motion correction techniques for all directions. Both contrast detection and motion correction work better on high-frame rate data. However high-frame rate 3-D...
conference paper 2022
document
Pirzadian, J. (author), Souhoka, T. (author), Herweijer, M. (author), van Heel, M.E. (author), van Wamel, W. J.B. (author), Goossens, R.H.M. (author), Severin, J. A. (author), Vos, M. C. (author)
In hospitals, sinks act as reservoirs for bacterial pathogens. To assess the extent of splashing, fluorescein dye was added to four hospital sinks previously involved in pathogen dispersal to the environment and/or transmission to patients, and one sink that was not. Applying dye to the p-trap or tailpiece did not result in any fluorescent...
journal article 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Kim, Taehoon (author), Noothout, E.C. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), De Jona, Nico (author)
Over the past decades, ultrasound imaging has made considerable progress based on the advancement of imaging systems as well as transducer technology. With the need for advanced transducer arrays with complex designs and technical requirements, there is also a need for suitable tools to characterize such transducers. However, despite the...
conference paper 2022
document
Wahyulaksana, G. (author), Wei, Luxi (author), Schoormans, Jasper (author), Voorneveld, J.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Suppressing tissue clutter is an essential step in blood flow estimation and visualization, even when using ultrasound contrast agents. Blind source separation (BSS)-based clutter filter for high-framerate ultrasound imaging has been reported to perform better in tissue clutter suppression than the conventional frequency-based wall filter and...
journal article 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Mozaffarzadeh, M. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Kim, T. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for...
journal article 2022
document
Heymans, Sophie V. (author), Collado Lara, G. (author), Rovituso, M. (author), Vos, H.J. (author), D'hooge, Jan (author), de Jong, N. (author), Van Den Abeele, Koen (author)
Superheated nanodroplet (ND) vaporization by proton radiation was recently demonstrated, opening the door to ultrasound-based in vivo proton range verification. However, at body temperature and physiological pressures, perfluorobutane nanodroplets (PFB-NDs), which offer a good compromise between stability and radiation sensitivity, are not...
journal article 2022
document
Guo, P. (author), Fool, F. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
The integration of 2D ultrasonic transducer arrays and pitch-matched ASICs has enabled the realization of various 3D ultrasound imaging devices in recent years [1]-[3]. As applications such as 3D intravascular ultrasonography, intra-cardiac echocardiography, and trans-fontanelle ultrasonography call for miniaturization and improved spatial...
conference paper 2022
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, C. (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
Intra-cardiac echography (ICE) probes (Fig. 32.2.1) are widely used in electrophysiology for their good procedure guidance and relatively safe application. ASICs are increasingly employed in these miniature probes to enhance signal quality and reduce the number of connections needed in mm-diameter catheters [1]-[5]. 3D visualization in real...
conference paper 2022
document
Venot, Jean Philippe (author), Vos, Jeroen (author), Zwarteveen, Margreet (author), Mdee, Anna (author), Ertsen, M.W. (author), Cleaver, Frances (author), Lankford, Bruce (author), Swatuk, Larry (author), Linton, Jamie (author), Harris, Leila M. (author)
journal article 2021
document
Salles, Sebastien (author), Shepherd, Jami (author), Vos, Hendrik J. (author), Renaud, G.G.J. (author)
Intraosseous blood circulation is thought to have a critical role in bone growth and remodeling, fracture healing, and bone disorders. However, it is rarely considered in clinical practice because of the absence of a suitable noninvasive in vivo measurement technique. In this work, we assessed blood perfusion in tibial cortical bone...
journal article 2021
document
Baylis, Francesca (author), Mlecnik, E. (author), Kwon, M. (author), de Snoo, Marianne (author), Oung, Oubbol (author), Nurali, Lina (author), Vos, Coen (author), M'Foungoulie, Kémal (author), Van de Vyver, Ighor (author), Van Camp, Bart (author), Vercruyce, Annick (author)
The Triple-A project aimed to install demonstration exemplars of a variety of low-carbon technologies to increase awareness and adoption of these (building/construction) technologies by homeowners. Through this, the adoption of low-carbon technologies became normalised and created ambassadors for the technologies who can influence other...
report 2021
document
Voorneveld, J.D. (author), Keijzer, L.B.H. (author), Strachinaru, Mihai (author), Bowen, Daniel J. (author), Mutluer, Ferit O. (author), van der Steen, A.F.W. (author), Ten Cate, Folkert (author), de Jong, N. (author), Vos, H.J. (author), Van den Bosch, Annemien E. (author), Bosch, Johan G. (author)
High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output to use for HFR echoPIV (PRF = 4900 Hz) in the left ventricle (LV) of patients. Three infusion...
journal article 2021
Searched for: collection%253Air
(81 - 100 of 338)

Pages