Searched for: department%3A%22Biomechanical%255C%252BEngineering%22
(1 - 3 of 3)
document
Meijneke, C. (author), Kragten, G.A. (author), Wisse, M. (author)
The Delft Hand 2 (DH-2) is an underactuated robot hand meant for industrial applications, having six degrees of freedom (DoF), one actuator (DoA) and no sensors. It was designed to provide a cheap and robust hand to grasp a large range of objects without damaging them. The goal of this paper is to assess the design and performance of the DH-2,...
journal article 2011
document
Birglen, L. (author), Kragten, C.A. (author), Herder, J.L. (author)
journal article 2010
document
Kragten, G.A. (author), Meijneke, C. (author), Herder, J.L. (author)
There is a lack of agreement in the literature as to what exactly quantifies the performance of underactuated hands. This paper proposes two benchmark tests to measure the ability of underactuated hands to grasp different objects and the ability to hold the objects when force disturbances apply. The first test determines the smallest and largest...
journal article 2010