Searched for: faculty%3A%22Applied%255C%252BSciences%22
(1 - 10 of 10)
document
Nemati, M. (author), Loozen, G.B. (author), Van der Wekken, N. (author), Van de Belt, G. (author), Urbach, H.P. (author), Bhattacharya, N. (author), Kenjeres, S. (author)
A preliminary comparative measurement between particle imaging velocimetry (PIV) and laser speckle contrast analysis (LASCA) to study pulsatile flow using ventricular assist device in a patient-specific carotid artery phantom is reported. These full-field optical techniques have both been used to study flow and extract complementary parameters....
journal article 2015
document
Reyes Reyes, A. (author), Hou, Z. (author), Van Mastrigt, E. (author), Horsten, R.C. (author), De Jongste, J.C. (author), Pijnenburg, M.W. (author), Urbach, H.P. (author), Bhattacharya, N. (author)
We present a broadband quantum cascade laser-based spectroscopic system covering the region between 850 and 1250 cm?1. Its robust multipass cavity ensures a constant interaction length over the entire spectral region. The device enables the detection and identification of numerous molecules present in a complex gas mixture without any pre...
journal article 2014
document
Nemati, M. (author), Presura, C.N. (author), Urbach, H.P. (author), Bhattacharya, N. (author)
Continuous health monitoring has become a major theme of our aging society. Portable devices play an important role here. Many optical portable devices are susceptible to motion induced artifacts. We have performed an experimental study for detection of fluid pulsation based on multi-exposure speckle images, in presence of motion induced...
journal article 2014
document
Nemati, M. (author), Wijshoff, R.W.C.G.R. (author), Stijnen, J.M.A. (author), Van Tuijl, S. (author), Bergmans, J.W.M. (author), Bhattacharya, N. (author), Urbach, H.P. (author)
We have performed an in vitro and in vivo study, based on laser speckle contrast analysis, to detect fluid pulsation in the presence of artifacts caused by the relative motion between the sample and the illumination source. We observe that the pulsation signal is clearly detectable for a range of motion amplitudes and oscillation frequencies;...
journal article 2013
document
Cui, M. (author), Zeitouny, M.G. (author), Bhattacharya, N. (author), Van den Berg, S.A. (author), Urbach, H.P. (author)
We experimentally demonstrate long distance measurements with a femtosecond frequency comb laser using dispersive interferometry. The distance is derived from the unwrapped spectral phase of the dispersed interferometer output and the repetition frequency of the laser. For an interferometer length of 50 m this approach has been compared to an...
journal article 2011
document
Zeitouny, M.G. (author), Cui, M. (author), Janssen, A.J. (author), Bhattacharya, N. (author), Van den Berg, S.A. (author), Urbach, H.P. (author)
We investigate general properties of the interferograms from a frequency comb laser in a non-linear dispersive medium. The focus is on interferograms at large delay distances and in particular on their broadening, the fringe formation and shape. It is observed that at large delay distances the interferograms spread linearly and that its shape is...
journal article 2011
document
Zeitouny, M.G. (author), Cui, M. (author), Bhattacharya, N. (author), Urbach, H.P. (author), Van den Berg, S.A. (author), Janssen, A.J.E.M. (author)
We have investigated correlation patterns generated by a frequency-comb laser in a dispersive unbalanced Michelson interferometer and apply the developed formalism to the case of distance metrology. Due to group velocity dispersion, the position of the brightest fringe of the correlation pattern, which is used for distance determination, cannot...
journal article 2010
document
Cui, M. (author), Zeitouny, M.G. (author), Bhattacharya, N. (author), Van den Berg, S.A. (author), Urbach, H.P. (author), Braat, J.J.M. (author)
We experimentally demonstrate that a femtosecond frequency comb laser can be applied as a tool for longdistance measurement in air. Our method is based on the measurement of cross correlation between individual pulses in a Michelson interferometer. From the position of the correlation functions, distances of up to 50 m have been measured. We...
journal article 2009
document
Cui, M. (author), Bhattacharya, N. (author), Urbach, H.P. (author), Van den berg, S.A. (author)
We experimentally demonstrate that a stabilized femtosecond frequency comb can be applied as a tool for distance measurement. The scheme is based on optical interference between individual pulses in a Michelson type interferometer. The cross-correlation functions between individual pulses with a distance of around 15 meter and 30 meter are...
conference paper 2008
document
Zeitouny, M. (author), Bhattacharya, N. (author), Urbach, H.P. (author), Van den Berg, S.A. (author)
Frequency and distance metrology have been revolutionized with the arrival of stabilized frequency comb lasers. We discuss several aspects of distance metrology specially the contribution of the dispersion in by air.
conference paper 2008
Searched for: faculty%3A%22Applied%255C%252BSciences%22
(1 - 10 of 10)