Searched for: subject%253A%2522Transducers%2522
(1 - 20 of 48)

Pages

document
Simoes dos Santos, D. (author), Ossenkoppele, B.W. (author), Hopf, Y.M. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Objective: Described here is the development of an ultrasound matrix transducer prototype for high-frame-rate 3-D intra-cardiac echocardiography. Methods: The matrix array consists of 16 × 18 lead zirconate titanate elements with a pitch of 160 µm × 160 µm built on top of an application-specific integrated circuit that generates transmission...
journal article 2024
document
Simoes dos Santos, D. (author), Baldini, L.B. (author), Vos, H.J. (author), Verweij, M.D. (author), de Jong, N. (author), van Neer, P.L.M.J. (author)
The accurate determination of the transfer function of ultrasound transducers is important for their design and operational performance. However, conventional methods for quantifying the transfer function, such as hydrophone measurements, radiation force balance, and pulse-echo measurements, are costly and complex due to specialized equipment...
journal article 2024
document
Galiana, Shankar (author), Moradi, M. (author), Wierach, Peter (author), Zarouchas, D. (author)
Acousto-ultrasonic composite transducers (AUCTs), comprising piezoceramic materials in a reinforced polymeric matrix, show promise for structural health monitoring in composite structures. Challenges arise when integrating AUCTs onto highly loaded thermoplastic composites, especially low-surface-energy materials like polyaryletherketone...
journal article 2024
document
Saccher, M. (author), Kawasaki, S. (author), Klootwijk, Johan (author), van Schaijk, Rob (author), Dekker, R. (author)
Recently, the applications of ultrasound transducers expanded from high-end diagnostic tools to point of care diagnostic devices and wireless power receivers for implantable devices. These new applications additionally require that the transducer technology must comply to biocompatibility and manufacturing scalability. In this respect,...
journal article 2023
document
Peng, W. (author), Du, S. (author)
A triboelectric nanogenerator (TENG) is a new transducer utilizing contact electrification and electrostatic induction to transform mechanical energy into electric energy. Due to its high energy density and flexibility, it can be employed to make electronic devices self-powered by harvesting ambient mechanical energy in many application...
journal article 2023
document
Rodrigues, Estevão P. (author), Simoes dos Santos, D. (author), Buiochi, Flávio (author)
The measurement of acoustic fields generated by ultrasonic transducers is important for determining the focal length, lateral resolution, and amplitudes of the lateral and grating lobes. The acoustic field is commonly characterized by a set of scans using a needle hydrophone. The output of the hydrophone can be connected to an analog filter to...
journal article 2023
document
Yue, X. (author), Du, S. (author)
Synchronized ac-dc rectifiers are widely used for energy rectification in piezoelectric energy harvesting (PEH), which have to employ a bulky inductor or some dedicated flying capacitors for high energy conversion efficiency. This article proposes a synchronized switch harvesting on shared capacitors (SSHSC) rectifier achieving synchronized...
journal article 2023
document
Yue, X. (author), Du, S. (author)
In the past decades, inductor-based synchronized switch harvesting on inductor (SSHI) rectifiers have been widely employed in many active rectification systems for piezoelectric energy harvesting. Although SSHI rectifiers achieve high energy extraction performance compared to passive full-bridge rectifier (FBR), the performance greatly...
journal article 2023
document
Liang, Hongping (author), Guo, Xin (author), Guo, Lanpeng (author), Liu, Siying (author), Zhan, Qiuqiang (author), Yang, Haihong (author), Li, Hao (author), de Rooij, Nicolaas Frans (author), Lee, Yi Kuen (author), French, P.J. (author), Wang, Yao (author), Zhou, Guofu (author)
Constructing near-infrared light (NIR) light-enhanced room temperature gas sensors is becoming more promising for practical application. In this study, learning from the structure and photosynthetic process of chlorophyll thylakoid membranes in plants, the first “Thylakoid membrane” structural formaldehyde (HCHO) sensor is constructed by...
journal article 2023
document
Valiya Valappil, S. (author), Goosen, J.F.L. (author), Aragon, A.M. (author)
Ultrasonic flowmeters that use transit-time ultrasonic transducers face measurement errors due to 'crosstalk,' whereby the working signal travels through the pipe wall and couplings, interfering with the signal from the fluid. Although various procedures have been proposed to solve the issue of crosstalk, they're limited to low-frequency...
journal article 2023
document
Rivandi, H. (author), Lopes Marta da Costa, T.M. (author)
Ultrasound (US) neuromodulation and ultrasonic power transfer to implanted devices demand novel ultrasound transmitters capable of steering focused ultrasound waves in 3D with high spatial resolution and US pressure, while having a miniaturized form factor. Meeting these requirements needs a 2D array of ultrasound transducers directly...
journal article 2023
document
Motreuil-Ragot, P.A. (author), Hunt, A. (author), Sacco, L.N. (author), Sarro, Pasqualina M (author), Mastrangeli, Massimo (author)
Ionic polymer metal composites (IPMCs) are a class of materials with a rising appeal in biological micro-electromechanical systems (bio-MEMS) due to their unique properties (low voltage output, bio-compatibility, affinity with ionic medium). While tailoring and improving actuation capabilities of IPMCs is a key motivator in almost all IPMC...
journal article 2023
document
Rashidi, A. (author), Zamani, M. (author), Mondal, Tanmay (author), Hosseini, Seyedsina (author), Laursen, Kjeld (author), Corbet, Brian (author), Moradi, Farshad (author)
This letter presents an ultrasonically powered dual-wavelength optogenetic device that targets simultaneous excitation and inhibition of neural activities, or in a broader sense, optical stimulation in two distinct wavelengths for targeting different populations of neurons. This can be applied to a variety of neurological disorders. The...
journal article 2023
document
Ossenkoppele, B.W. (author), Luijten, Ben (author), Bera, Deep (author), de Jong, N. (author), Verweij, M.A. (author), van Sloun, Ruud J.G. (author)
There is an increased desire for miniature ultrasound probes with small apertures to provide volumetric images at high frame rates for in-body applications. Satisfying these increased requirements makes simultaneous achievement of a good lateral resolution a challenge. As micro-beamforming is often employed to reduce data rate and cable count...
journal article 2023
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe...
journal article 2022
document
Hakakzadeh, Soheil (author), Mozaffarzadeh, M. (author), Mostafavi, S.. (author), Kavehvash, Zahra (author), Rajendran, Praveenbalaji (author), Verweij, M.D. (author), de Jong, N. (author), Pramanik, Manojit (author)
In photoacoustic tomography (PAT) systems, the tangential resolution decreases due to the finite size of the transducer as the off-center distance increases. To address this problem, we propose a multi-angle detection approach in which the transducer used for data acquisition rotates around its center (with specific angles) as well as around...
journal article 2022
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a compact analog front-end (AFE) circuit for ultrasound receivers with linear-in-dB continuous gain control for time-gain compensation (TGC). The AFE consists of two variable-gain stages, both of which employ a novel complementary current-steering network (CCSN) as the interpolator to realize continuously variable gain....
journal article 2022
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this letter, a compact high-voltage (HV) transmit circuit for dense 2-D transducer arrays used in 3-D ultrasonic imaging systems is presented. Stringent area requirements are addressed by a unipolar pulser with embedded transmit/receive switch. Combined with a capacitive HV level shifter, it forms the ultrasonic HV...
journal article 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Mozaffarzadeh, M. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Kim, T. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for...
journal article 2022
document
Heymans, Sophie V. (author), Collado Lara, G. (author), Rovituso, M. (author), Vos, H.J. (author), D'hooge, Jan (author), de Jong, N. (author), Van Den Abeele, Koen (author)
Superheated nanodroplet (ND) vaporization by proton radiation was recently demonstrated, opening the door to ultrasound-based in vivo proton range verification. However, at body temperature and physiological pressures, perfluorobutane nanodroplets (PFB-NDs), which offer a good compromise between stability and radiation sensitivity, are not...
journal article 2022
Searched for: subject%253A%2522Transducers%2522
(1 - 20 of 48)

Pages