Searched for: subject%253A%2522Transducers%2522
(1 - 11 of 11)
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Yue, X. (author), Zou, Yiwei (author), Chen, Zhelun (author), Liang, Junrui (author), Du, S. (author)
Synchronized switch harvesting on inductor (SSHI) is an efficient active rectifier to extract energy generated from piezoelectric transducer in piezoelectric energy harvesting system. Unlike passive rectifiers, SSHI rectifiers require a power supply to drive synchronized switches. Unfortunately, there is no stable supply when the system starts...
conference paper 2022
document
Yue, X. (author), Chen, Zhelun (author), Zou, Yiwei (author), Du, S. (author)
Ultrasonic wireless power transfer (WPT) has been proved to be a promising approach to power biomedical implants. To extract the energy generated from the transducer, a rectifier is typically required. Previous inductor-based rectifiers (SSHI and SECE) require a large off-chip inductor to achieve good performance, which is not desired for...
conference paper 2022
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, C. (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
Intra-cardiac echography (ICE) probes (Fig. 32.2.1) are widely used in electrophysiology for their good procedure guidance and relatively safe application. ASICs are increasingly employed in these miniature probes to enhance signal quality and reduce the number of connections needed in mm-diameter catheters [1]-[5]. 3D visualization in real...
conference paper 2022
document
Tan, M. (author), Chen, C. (author), Chen, Z. (author), Janjic, Jovana (author), Daeichin, V. (author), Chang, Z.Y. (author), Noothout, E.C. (author), van Soest, G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an area- and power-efficient application-specified integrated circuit (ASIC) for 3-D forward-looking intravascular ultrasound imaging. The ASIC is intended to be mounted at the tip of a catheter, and has a circular active area with a diameter of 1.5 mm on the top of which a 2-D array of piezoelectric transducer elements is...
journal article 2018
document
Daeichin, V. (author), Bera, D. (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Chen, Z. (author), Chen, C. (author), Noothout, E.C. (author), Vos, H.J. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a...
journal article 2018
document
Janjic, Jovana (author), Tan, M. (author), Daeichin, V. (author), Noothout, E.C. (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Beurskens, Robert H.S.H. (author), van Soest, G. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author), de Jong, N. (author)
Intravascular ultrasound is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking intravascular ultrasound (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2D array...
journal article 2018
document
Bera, D. (author), Raghunathan, S.B. (author), Chen, C. (author), Chen, Z. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, J.G. (author)
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently...
journal article 2018
document
D'Urbino, Michele (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Lippe, Boris (author), Pertijs, M.A.P. (author)
This paper presents a power- and area-efficient approach to digitizing the echo signals received by piezoelectric transducer elements, commonly used for ultrasound imaging. This technique utilizes such elements not only as sensors but also as the loop filter of an element-level δσ analog to digital converter (ADC). The receiver chain is thus...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Prins, Christian (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm<sup>2</sup> ASIC, implemented...
journal article 2017
document
Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Pertijs, M.A.P. (author)
This paper presents a power- and area-efficient 9-channel LNA array for piezoelectric ultrasound transducers to enable real-time 3D imaging with miniature endoscopic and catheter-based probes. In view of the relatively low impedance of piezoelectric transducers, the LNA is implemented as a capacitive feedback voltage amplifier, rather than a...
conference paper 2015
Searched for: subject%253A%2522Transducers%2522