Searched for: subject%3A%22Adaptive%255C%252Boptics%22
(1 - 20 of 28)

Pages

document
Broekens, K.A. (author), Klop, Wimar (author), Moens, Thijs (author), Eschen, M. (author), Castro do Amaral, G. (author), Silverstri, Fabrizio (author), Visser, Martijn (author), Kaffa, Lauren (author), Saathof, R. (author)
For the next generation of very high throughput communication satellites, free-space optical (FSO) communication between ground stations and geostationary telecommunication satellites is a potential solution to overcome the limitations of RF links. To mitigate atmospheric turbulence effects, TNO proposes Adaptive Optics (AO) to apply uplink...
conference paper 2023
document
Piscaer, P.J. (author), Soloviev, O.A. (author), Verhaegen, M.H.G. (author)
This paper discusses various practical problems arising in the design and simulation of predictive control methods for adaptive optics. Although there has been increased attention towards optimal prediction and control methods for AO systems, they are often tested in simplified simulation environments. The use of advanced AO simulators...
conference paper 2020
document
Stuik, Remko (author), Arcier, Benjamin (author), Brandl, B.R. (author)
METIS, the Mid-IR instrument for the ELT will be operating an internal Single Conjugate Adaptive Optics System (SCAO), which will be the work horse AO system and mainly serve the science cases targeting exoplanets and disks around bright stars. In order to extend the sky coverage and brightness range of targets requiring AO correction to...
conference paper 2019
document
Quintavalla, M. (author), Pozzi, P. (author), Verhaegen, M.H.G. (author), Bijlsma, H.K. (author), Verstraete, H.R.G.W. (author), Bonora, S. (author)
Adaptive Optics (AO) has revealed as a very promising technique for high-resolution microscopy, where the presence of optical aberrations can easily compromise the image quality. Typical AO systems however, are almost impossible to implement on commercial microscopes. We propose a simple approach by using a Multi-actuator Adaptive Lens (MAL)...
conference paper 2018
document
Wilding, D. (author), Pozzi, P. (author), Soloviev, O.A. (author), Vdovin, Gleb (author), Verhaegen, M.H.G. (author)
In life sciences, interest in the microscopic imaging of increasingly complex three dimensional samples, such as cell spheroids, zebrafish embryos, and in vivo applications in small animals, is growing quickly. Due to the increasing complexity of samples, more and more life scientists are considering the implementation of adaptive optics in...
conference paper 2018
document
Pozzi, P. (author), Wilding, D. (author), Soloviev, O.A. (author), Vdovin, Gleb (author), Verhaegen, M.H.G. (author)
In this work, we present a new confocal laser scanning microscope capable to perform sensorless wavefront optimization in real time. The device is a parallelized laser scanning microscope in which the excitation light is structured in a lattice of spots by a spatial light modulator, while a deformable mirror provides aberration correction and...
conference paper 2018
document
Wilding, D. (author), Pozzi, P. (author), Soloviev, O.A. (author), Vdovin, Gleb (author), Fiolka, Reto (author), Verhaegen, M.H.G. (author)
The light-sheet fluorescence microscopy is an excellent tool for the investigation of large three dimensional microscopy samples at the cellular level, however, the ability to resolve features is strongly affected by the presence of scattering and aberrations. These effects are two fold in light-sheet microscopy, as the illumination path...
conference paper 2018
document
Mocci, J. (author), Cua, M. (author), Lee, S. (author), Jian, Y (author), Pozzi, P. (author), Quintavalla, M. (author), Trestino, C. (author), Verstraete, H.R.G.W. (author), Wahl, D. (author), Muradore, R. (author), Zawadzki, R.J. (author), Verhaegen, M.H.G. (author), Sarunic, M.V. (author), Bonora, S. (author)
The use of adaptive lenses instead of deformable mirrors can simplify the implementation of an adaptive optics system. The recently introduced Multi-actuator Adaptive Lens (MAL) can be used in closed loop with a wavefront sensor to correct for time-variant wavefront aberrations. The MAL can guarantee a level of correction and a response time...
conference paper 2017
document
Gong, H. (author), Pozzi, P. (author), Soloviev, O.A. (author), Verhaegen, M.H.G. (author), Vdovin, Gleb (author)
We present a reference-less and time-multiplexing phase retrieval method by making use of the digital micromirror device (DMD). In this method, the DMD functions not only as a flexible binary mask which modulates the optical field, but also as a sampling mask for measuring corresponding phases, which makes the whole setup simple and robust. The...
conference paper 2016
document
Yoo, H.W. (author), van Royen, M.E. (author), van Cappellen, WA (author), Houtsmuller, AB (author), Verhaegen, M.H.G. (author), Schitter, G (author)
The pinhole plays an important role in confocal laser scanning microscopy (CLSM) for adaptive optics (AO) as well as in imaging, where the size of the pinhole denotes a trade-off between out-of-focus rejection and wavefront distortion. This contribution proposes an AO system for a commercial CLSM with an adjustable square pinhole to cope with...
conference paper 2016
document
Verstraete, H.R.G.W. (author), Almasian, M. (author), Pozzi, P. (author), Bilderbeek, R (author), Kalkman, J. (author), Faber, DJ (author), Verhaegen, M.H.G. (author)
In this manuscript, we present a lens setup for large defocus and astigmatism correction. A deformable defocus lens and two rotational cylindrical lenses are used to control the defocus and astigmatism. The setup is calibrated using a simple model that allows the calculation of the lens inputs so that a desired defocus and astigmatism are...
conference paper 2016
document
Wilding, D. (author), Pozzi, P. (author), Soloviev, O.A. (author), Vdovin, Gleb (author), Verhaegen, M.H.G. (author)
Aberrations, scattering and absorption degrade the performance light-sheet fluorescence microscopes (LSFM). An adaptive optics system to correct for these artefacts and to optimize the light-sheet illumination is presented. This system allows a higher axial resolution to be recovered over the field-of-view of the detection objective. It is...
conference paper 2016
document
Agbana, T.E. (author), Yang, H. (author), Soloviev, O.A. (author), Vdovin, Gleb (author), Verhaegen, M.H.G. (author)
This paper presents experimental results of a static aberration control algorithm based on the linear relation be- tween mean square of the aberration gradient and the second moment of point spread function for the generation of control signal input for a deformable mirror (DM). Results presented in the work of Yang et al.1 suggested a good...
conference paper 2016
document
Habets, Michel (author), Scholten, Joni (author), Weiland, Siep (author), Coene, W.M.J.M. (author)
The imaging quality of the projection optics of an extreme ultraviolet lithography scanner degrades under the influence of thermally induced deformations of its mirrors. Wavefronts of different reticle points encounter different parts of the deformed mirrors, resulting in a field dependent wavefront error. This paper presents how ideas from...
conference paper 2016
document
Agbana, T.E. (author), Soloviev, O. (author), Bezzubik, V. (author), Patlan, V. (author), Verhaegen, M. (author), Vdovin, G.V. (author)
We have implemented an extended depth of field optical system by wavefront coding with a micromachined membrane deformable mirror. This approach provides a versatile extension to standard wavefront coding based on fixed phase mask. First experimental results validate the feasibility of the use of adaptive optics for variable depth wavefront...
conference paper 2015
document
Soloviev, O.A. (author), Verhaegen, M.H.G. (author), Vdovin, Gleb (author)
Shack-Hartmann (SH) sensor, based on sampling of wavefront tilts in subapertures, is a simple, reliable, and widely used in adaptive optics wavefront sensor. A wavefront curvature sensor has the advantage of providing the results suitable for direct control of membrane and bimorph deformable mirrors [1], but requires linear registration of...
conference paper 2015
document
Ten Have, E.S. (author), Vdovin, G. (author)
Closed-loop adaptive optical correction using a deformable mirror based on the total internal reflection (TIR) from an electrostatically deformed liquid-air interface was performed on a collimated beam of a HeNe-laser that was aberrated by a rotating phase disk. The frequency response of the system was measured and the influence of liquid...
conference paper 2011
document
Fraanje, R. (author), Doelman, N. (author)
In recent years various researchers have proposed an optimal control approach for the rejection of turbulence-induced wavefront distortions in an AO system. The essential element in the design of an optimal controller is the choice for the turbulence model, which predicts the turbulence to compensate for the inherent delay in the AO control loop...
conference paper 2010
document
Loktev, M. (author), Vdovin, G. (author), Soloviev, O. (author)
We describe a compact integrated module implementing a low-cost adaptive optics system. It is targeted as a correction system for small telescopes with primary mirror diameter up to 1 m, operating on a natural guide star with magnitude at least 4 (for a 25 cm telescope). It is supposed to provide stable diffraction-limited imaging of stars,...
conference paper 2008
document
Hinnen, K. (author), Verhaegen, M. (author), Doelman, N. (author)
Most adaptive optics systems (AO) are based on a simple control law that is unable to account for the temporal evolution of the wavefront. In this paper, a recently proposed data-driven H2-optimal control approach is demonstrated on an AO laboratory setup. The proposed control approach does not assume any form of decoupling and can therefore...
conference paper 2006
Searched for: subject%3A%22Adaptive%255C%252Boptics%22
(1 - 20 of 28)

Pages