document
Singh, Abhiraj (author)
Lung-on-Chip (LoC) are devices that give cells a habitat in vitro that tries to more nearly imitate their natural environment in vivo. This microscale bio-mimetic device is designed to replicate essential features of the human lung within a controlled environment. While advancements in microfluidic technology have been substantial, the lung-on...
master thesis 2024
document
Zhao, W. (author), Ghafoor, S. (author), Lagerweij, Gijs Willem (author), Rietveld, Gert (author), Vaessen, P.T.M. (author), Ghaffarian Niasar, M. (author)
This paper comprehensively reviews several techniques that address the static and dynamic voltage balancing of series-connected MOSFETs. The effectiveness of these techniques was validated through simulations and experiments. Dynamic voltage-balancing techniques include gate signal delay adjustment methods, passive snubbers, passive clamping...
journal article 2024
document
van Willigen, D.M. (author)
This thesis describes the design, prototyping and evaluation of matrix-based clamp-on ultrasonic flow meters. Several new measurement techniques are presented as well as an Application-Specific Integrated Circuit (ASIC) designed for accurate measurement of flow velocity with matrix transducers.<br/><br/>The influence of circuit topologies on the...
doctoral thesis 2022
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe...
journal article 2022
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Noothout, E.C. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Common clamp-on ultrasonic flow meters consist of two single-element transducers placed on the pipe wall. Flow speed is measured noninvasively, i.e., without interrupting the flow and without perforating the pipe wall, which also minimizes safety risks and avoids pressure drops inside the pipe. However, before metering, the transducers have...
journal article 2022
document
Zaccaria, Marco (author), Peters, Timon (author), Ebert, Jan (author), Lucca, Nerio (author), Schneider, Jens (author), Louter, P.C. (author)
The bending strength of flat glass panels including the effects of their edges, is commonly determined by means of the four-point bending test method. This is an established and reliable method. However, when testing glass thinner than 3 mm, large deformation may occur. This means that the calculated stresses might not correspond to the...
journal article 2022
document
Donders, Wouter (author)
Worldwide 70-90% of hospitalised patients receive intravenous infusion at some stage during their stay. In many situations, a high degree of infusion accuracy is essential as deviation from the intended dose can quickly become dangerous and moreover costly. Electronic infusion pumps provide the most accurate way of infusion, but they require...
master thesis 2021
document
del Rivero Cortázar, Aitor (author)
The need to understand how the brain works has sparked interest in electrode arrays to record neural signals. Intracellular recordings with nanoelectrodes that penetrate the cell allow better signal quality and additional functions such as voltage clamping to set the neuron's transmembrane voltage. The voltage clamp aims to facilitate the...
master thesis 2021
document
van Dam, Daniël (author)
Suspended microchannel resonators are a kind of mechanical resonator with an embedded microchannel inside. This is done as for some samples it is convenient or even necessary to put the sample into a fluid. The sample can then travel through the channel and its mass can be determined. The channel also simplifies placement of the samples compared...
master thesis 2021
document
Bediako, M. (author), Opoku Amankwah, E. (author), Valentini, L. (author)
Clamp-firing system is a cost-effective technology used to produce burnt clay bricks in many West African countries including Ghana. However, this firing system generates between 7%- 15% of waste in a form of burnt broken bricks and with time creates disposal problems. In this work, burnt clay broken bricks were sampled and pulverised to 75...
conference paper 2021
document
Massaad Mouawad, J.M. (author)
Ultrasonic flow meters are widely applied to measure flow in a variety of applications. The vast majority of ultrasonic flow meters are based on the measurement of the transit time of an acoustic pulse through the fluid. This can either be done in-line, by inserting a spool piece with ultrasonic transducers into the pipe carrying the fluid, or...
doctoral thesis 2021
document
Shin, D. (author), Cupertino, A. (author), de Jong, M.H.J. (author), Steeneken, P.G. (author), Bessa, M.A. (author), Norte, R.A. (author)
From ultrasensitive detectors of fundamental forces to quantum networks and sensors, mechanical resonators are enabling next-generation technologies to operate in room-temperature environments. Currently, silicon nitride nanoresonators stand as a leading microchip platform in these advances by allowing for mechanical resonators whose motion...
journal article 2021
document
Bloemberg, J. (author), Stefanini, Cesare (author), Romano, Donato (author)
Insects are important agents in ecosystems. Their diverseness and developed coping mechanisms also make them interesting for direct application and as a source of inspiration in medical engineering. We summarized the main contribution of insects in biomedical applications. Medical centers in North America, and Europe use fly larvae for maggot...
journal article 2021
document
Stecca, M. (author), Soeiro, Thiago B. (author), Ramirez Elizondo, L.M. (author), Bauer, P. (author), Palensky, P. (author)
This paper discusses a qualitative comparison between Two and Three-Level Voltage Source Converter (VSC) topologies for battery energy storage applications. Three-Level Neutral Point Clamped (NPC) and T-Type circuit topologies are benchmarked versus the state-of-art Two-Level VSC in terms of efficiency and power density considering a 100 kW...
conference paper 2020
document
Sideris, Eva Ann (author), De Lange, Hendrik Cornelis (author), Hunt, A. (author)
Microfluidic devices and micro-pumps are increasingly necessitated in many fields ranging from untethered soft robots, to pharmaceutical and biomedical technology. While realization of such devices is limited by miniaturization constraints of conventional actuators, these restrictions can be resolved by using smart material transducers...
journal article 2020
document
Motyka, Alicja (author)
Female sterilisation is difficult to access in many low- and middle-income countries. Opt Medical wants to solve this problem by developing a clip that can be placed around the Fallopian tubes during C-sections without immediately affecting the fertility. By activating the clip at a suitable time, a clamping mechanism occludes the Fallopian tube...
master thesis 2019
document
van der Zalm, Joost (author)
The goal of the research described in this thesis was to investigate the basis of dissipation dilution as well as make it comprehensible. In the written literature we could find that the kinetic energy of an oscillating beam is stored into two types of potential energy~\cite{Kippenberg, Kotthaus}. A dissipative bending component and a...
bachelor thesis 2019
document
Li, Ruyu (author)
A driver with high power factor, high efficiency and safety isolation are more attractive in the lighting application. Flyback is an ideal choice to be the power factor stage in LED driver. But one of the most difficulty in flyback topology is the energy stored in its leakage inductance. This part of the energy will introduce very high voltage...
master thesis 2017
document
Hulsebos, M. (author)
With electron beam lithography, a cutting edge technology has been developed that might introduce new possibilities in the design of chips. The word "might" has been used here because e-beam lithography is not yet available for the mass production market. One of the bottlenecks in the development of e-beam lithography is the positioning...
master thesis 2017
document
Van Dongen, M.N. (author), Hoebeek, F.E. (author), Koekkoek, S.K.E. (author), De Zeeuw, C.I. (author), Serdijn, W.A. (author)
This paper investigates the efficacy of high frequency switched-mode neural stimulation. Instead of using a constant stimulation amplitude, the stimulus is switched on and off repeatedly with a high frequency (up to 100 kHz) duty cycled signal. By means of tissue modeling that includes the dynamic properties of both the tissue material as well...
journal article 2015