Searched for: subject%3A%22Partial%255C+Discharge%255C+%255C%2528PD%255C%2529%22
(1 - 13 of 13)
document
Chen, Y. (author), Castro Heredia, L.C. (author), Smit, J.J. (author), Ghaffarian Niasar, M. (author), Ross, Robert (author)
Partial discharge (PD) detection is a standardized technique to qualify the insulation condition in power equipment. The main purpose of the article is to evaluate the performance of an extra high-sensitivity adapted giant magneto-resistive (xMR) sensor for non-contacting PD detection. First, compensation and signal conditioning circuits of...
journal article 2023
document
Chen, Y. (author), Castro Heredia, L.C. (author), Smit, J.J. (author), Ghaffarian Niasar, M. (author), Ross, Robert (author)
Partial discharges (PD) detection is an effective diagnostic method to assess the insulation condition of electrical power equipment in the high-voltage laboratory or field tests. This paper presents a non-contacting PD detection method for power equipment. The method is based on an extra high-sensitivity adapted giant magneto-resistive (xMR)...
journal article 2023
document
Zang, Y. (author), Ghaffarian Niasar, M. (author), Ganeshpure, D.A. (author), Qian, Yong (author), Sheng, Gehao (author), Jiang, Xiuchen (author), Vaessen, P.T.M. (author)
With the widespread application of power electronic switching technology, power equipment is facing new electrical stresses brought about by multilevel staircase voltages during testing and operation. Therefore, the partial discharge (PD) behavior of five typical defects in power equipment under the staircase waveform needs to be investigated...
journal article 2022
document
Abdul Madhar, S. (author), Mor, A. R. (author), Mraz, Petr (author), Ross, Robert (author)
This paper presents the investigation on surface discharge behavior of various dielectric samples under DC. It sequentially develops the knowledge base for the study and analysis of the partial discharge (PD) defect with the goal of PD defect identification under DC. In order to facilitate this, the material properties of the dielectric are...
journal article 2021
document
Abdul Madhar, S. (author), Brunner, Marc (author), Mor, A. R. (author), Mraz, Petr (author)
The discharge over dielectric interfaces popularly known as surface discharge is a very common defect type that is associated with its respective discharge pattern under AC voltages. However, the same designs behave differently under DC voltages leading up to erratic PD behavior. To understand the process of surface discharge an equivalent...
conference paper 2021
document
Abdul Madhar, S. (author), Mraz, Petr (author), Mor, A. R. (author), Ross, Robert (author)
This paper presents several approaches to the analysis of partial discharge (PD) data. Three common defects namely corona, surface and floating electrode are studied with the goal of defect identification under DC stress conditions. One of the major concerns with DC-PD testing, is its non-repetitive/erratic pulse pattern. This paper, however,...
journal article 2020
document
Abdul Madhar, S. (author), Mraz, Petr (author), Mor, A. R. (author), Ross, Robert (author)
Corona is one of the most common forms of partial discharge (PD) occurring in high voltage (HV) energy systems. The corona mechanism in air is not exclusive to the field of energy applications but has also been widely studied by physicists to theorize mechanisms of charge transfer during the different phases of gas discharge. The phases of the...
journal article 2020
document
Wu, J. (author), Smit, J.J. (author), Mor, A. R. (author)
In practice, High-voltage (HV) cables are occasionally exposed to impulse and superimposed transient conditions, which may initiate partial discharges (PD) temporarily. Whether such PDs persist under AC voltage after the transient conditions have vanished, is at focus in the research described in this paper. Since for cross-linked polyethylene ...
journal article 2020
document
Abdul Madhar, S. (author), Mraz, Petr (author), Mor, A. R. (author), Ross, Robert (author)
Partial discharge is a prevalent phenomenon under high voltage (HV) where the discharge partially bridges the gap between two electrodes. At increasing voltage levels, physical dimensions and distances between the electrical parts become critical. Designing electrical components for such high voltages and planning of high voltage laboratories...
journal article 2019
document
Mor, A. R. (author), Muñoz Muñoz, F.A. (author), Wu, J. (author), Castro Heredia, L.C. (author)
This paper presents a new wavelet analysis approach in partial discharges cable joint measurements in noisy environments. The proposed technique uses the Cross Wavelet Transform (XWT) to separate PD signals from noise and external disturbances in partial discharges measurements in cable joints using two opposite polarity sensors. The partial...
journal article 2019
document
Abdul Madhar, S. (author), Mraz, Petr (author), Raquel Barrios Pereira, Sonia (author), Akroud, Nabil (author)
Asset condition monitoring through Partial Discharge (PD) measurements is widely used for pre-emptive maintenance especially in cable networks. Several monitoring systems rely on measurements in the High Frequency (HF) band using wideband sensors when it comes to PD monitoring to have higher Signal to Noise Ratios (SNR), ignoring the radical...
conference paper 2019
document
Mor, A. R. (author), Muñoz Muñoz, F.A. (author), Castro Heredia, L.C. (author)
This paper presents a new concept for partial discharge measurements in gas insulated systems (GIS). The proposed technique uses a novel GIS magnetic antenna that measures the magnetic field produced by partial discharges (PD) propagating in GIS. The foundations of the measurement technique and the magnetic antenna design are presented...
journal article 2019
document
Wu, J. (author), Mor, A. R. (author), Smit, J.J. (author)
In practice, cross-linked polyethylene (XLPE) power cables can be subjected to alternating voltage with superimposed impulse transients. Such impulse transients may initiate partial discharges (PD) in insulation defects even below AC inception voltage. An initiated PD may persist under AC, which will cause insulation degradation. This paper...
journal article 2019
Searched for: subject%3A%22Partial%255C+Discharge%255C+%255C%2528PD%255C%2529%22
(1 - 13 of 13)