Searched for: subject%3A%22sparse%255C+array%22
(1 - 10 of 10)
document
Zhang, H. (author)
In recent decades, dielectric lens antennas have been more and more adopted and developed for sensing and imaging applications at sub-millimeter (sub-mm) wavelengths because they can achieve high gain while keeping their physical size and weight acceptable at these wavelengths. More recently, as low-loss and low-cost lens materials have become...
doctoral thesis 2024
document
Wei, Luxi (author), Wahyulaksana, G. (author), Boni, Enrico (author), Noothout, E.C. (author), Tortoli, Piero (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Vos, H.J. (author)
Volumetric echocardiography can potentially give a more complete picture of cardiac dynamics than its two-dimensional (2D) counterpart. Current clinical volumetric imaging probes have relatively low frame rates, and often require ECG gating to stitch together an entire volume. This makes measuring fast dynamics of the heart as well as imaging...
conference paper 2023
document
Wei, Luxi (author), Boni, Enrico (author), Ramalli, Alessandro (author), Fool, F. (author), Noothout, E.C. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Tortoli, Piero (author), de Jong, N. (author), Vos, H.J. (author)
Two-dimensional (2-D) arrays offer volumetric imaging capabilities without the need for probe translation or rotation. A sparse array with elements seeded in a tapering spiral pattern enables one-to-one connection to an ultrasound machine, thus allowing flexible transmission and reception strategies. To test the concept of sparse spiral array...
journal article 2022
document
Ossenkoppele, B.W. (author), Wei, Luxi (author), Luijten, Ben (author), Vos, H.J. (author), de Jong, N. (author), Van Sloun, Ruud J.G. (author), Verweij, M.D. (author)
3-D contrast enhanced ultrasound enables better visualization of inherently 3-D vascular geometries compared to an intersecting plane. Additionally, it would allow the application of motion correction techniques for all directions. Both contrast detection and motion correction work better on high-frame rate data. However high-frame rate 3-D...
conference paper 2022
document
Wei, Luxi (author), Wahyulaksana, G. (author), Meijlink, Bram (author), Ramalli, Alessandro (author), Noothout, E.C. (author), Verweij, M.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter...
journal article 2021
document
Aslan, Y. (author), Roederer, A.G. (author), Yarovoy, Alexander (author)
A comprehensive review on the approaches for synthesizing low side lobe concentric ring array (CRA) antennas is given. An Iterative Convex Optimization (ICO) based array layout synthesis technique is proposed for peak side-lobe level (PSLL) minimization over a given circular field-of-view in steerable uniform-amplitude concentric ring array (UA...
journal article 2021
document
Aslan, Y. (author), Puskely, J. (author), Roederer, A.G. (author), Yarovoy, Alexander (author)
The impact of reducing the total number of elements in passively-cooled, chip-integrated and space-tapered 5G base station antenna arrays on inter-beam interferences and chip temperatures is investigated for multi-user spacedivision-multiple-access applications. A convex element position optimization algorithm is used to synthesize the array...
conference paper 2020
document
Rossi, Stefano (author), Ramalli, Alessandro (author), Fool, F. (author), Tortoli, Piero (author)
Ultrasound vector Doppler techniques for three-dimensional (3-D) blood velocity measurements are currently limited by low temporal resolution and high computational cost. In this paper, an efficient 3-D high-frame-rate vector Doppler method, which estimates the displacements in the frequency domain, is proposed. The novel method extends to 3...
journal article 2020
document
Aslan, Y. (author), Puskely, J. (author), Janssen, J. H. J. (author), Geurts, Marcel (author), Roederer, A.G. (author), Yarovoy, Alexander (author)
Heat removal capabilities and radiation performances of several sparse antenna array topologies are studied for cooling enhancement in 5G millimeter-wave base station antennas. Both electromagnetic and thermal aspects are jointly considered for the first time in array layout optimization and a novel connection between layout sparsity and thermal...
journal article 2018
document
Zhuge, X. (author)
Compact, cost-efficient and high-resolution imaging sensors are especially desirable in the field of short-range observation and surveillance. Such sensors are of great value in fields of security, rescue and medical applications. Systems can be formed for various practical purposes, such as detecting concealed weapons in public places, locating...
doctoral thesis 2010
Searched for: subject%3A%22sparse%255C+array%22
(1 - 10 of 10)