Mechanical analysis and novel solution

In recent years, steerable catheters have been developed to combat the effects of the dynamic cardiac environment. Mechanically actuated steerable catheters appear the most in the clinical setting; however, they are bound to a number of mechanical limitations. The aim of this research is to gain insight in these limitations and use this information to develop a new prototype of a catheter with increased steerability. The main limitations in mechanically steerable catheters are identified and analysed, after which requirements and solutions are defined to design a multi-steerable catheter. Finally, a prototype is built and a proof-of-concept test is carried out to analyse the steering functions. The mechanical analysis results in the identification of five limitations: (1) low torsion, (2) shaft shortening, (3) high unpredictable friction, (4) coupled tip-shaft movements, and (5) complex cardiac environment. Solutions are found to each of the limitations and result in the design of a novel multi-steerable catheter with four degrees of freedom. A prototype is developed which allows the dual-segmented tip to be steered over multiple planes and in multiple directions, allowing a range of complex motions including S-shaped curves and circular movements. A detailed analysis of limitations underlying mechanically steerable catheters has led to a new design for a multi-steerable catheter for complex cardiac interventions. The four integrated degrees of freedom provide a high variability of tip directions, and repetition of the bending angle is relatively simple and reliable. The ability to steer inside the heart with a variety of complex shaped curves may potentially change conventional approaches in interventional cardiology towards more patient-specific and lower complexity procedures. Future directions are headed towards further design optimizations and the experimental validation of the prototype. ...

Assessing 2DOF vs. 4DOF steerable instrument control

Iterative prototyping is costly and time-consuming. Particularly when designing medical instruments, human factors related design choices significantly impact performance and safety. A tool is presented that allows for the evaluation of steerable instrument controls before the onset of the prototyping stage. The design tool couples gestural input to virtually simulated instrument motions using hand motion tracking. We performed a human-subject evaluation of two manual control strategies that differed in their degrees of freedom (DOF). 2DOF thumb control was compared to 4DOF thumb-index finger control. Results identified regions within the instrument workspace that are difficult to reach and showed participants to favor using the thumb for gross and fine-tuning motions at both control strategies. Index finger ab/adduction was found to be least functional. A strong learning effect was observed at 4DOF control. Based on the results, gesture-based instrument design is a viable design tool. ...
The field of minimally invasive surgery (MIS) is constantly evolving towards the minimization of surgical trauma. Surgical instrumentation enabling this advancement must aid the surgeon, rather than hamper or burden. Surgeon-Instrument Interaction (SII) is of particular importance. Bad SII-design choices during instrument development can complicate procedures, introduce errors, and compromise patient safety. The objective of this thesis is to evaluate and improve SII for MIS instrumentation and to investigate new ways to design for SII, such that potential complications of future instrumentation are avoided.
This thesis is divided into two parts, each relating to an instrument for which the investigation of SII is of significant relevance. Part I discusses the gynaecological morcellator, a dedicated instrument that facilitates the laparoscopic removal of bulk uterine tissue. Contrasting the single-purpose morcellation instrument, Part II discusses multi-functional instrumentation. Specifically, Part II investigates multi-branched instrumentation for natural orifice transluminal endoscopic surgery (NOTES) and presents a new design method towards their future development.
...

Trainees and experts

The benefits of electrosurgery have been acknowledged since the early 1920s, and nowadays more than 80% of surgical procedures involve devices that apply energy to tissues. Despite its widespread use, it is currently unknown how the operator's choices with regard to instrument selection and application technique are related to complications. As such, the manner in which electrosurgery is applied can have a serious influence on the outcome of the procedure and the well-being of patients. The aim of this study is to investigate the variety of differences in usage of electrosurgical devices. Our approach is to measure these parameters to provide insight into application techniques. A sensor was developed that records the magnitude of electric current delivered to an electrosurgical device at a frequency of 10 Hz. The sensor is able to detect device activation times and a reliable estimate of the power-level settings. Data were recorded for 91 laparoscopic cholecystectomies performed by different surgeons and residents. Results of the current measurement data show differences in the way electrosurgery is applied by surgeons and residents during a laparoscopic cholecystectomy. Variations are seen in the number of activations, the activation time, and the approach for removal of the gallbladder. Analysis showed that experienced surgeons have a longer activation time than residents (3.01 vs 1.41 seconds, P <.001) and a lower number of activations (102 vs 123). This method offers the opportunity to relate application techniques to clinical outcome and to provide input for the development of a best practice model. ...
Review (2017) - Davey Kreeft (student), Ewout Aart Arkenbout, Paulus Wilhelmus Johannes Henselmans, Wouter R. Van Furth, Paul Breedveld
A clear visualization of the operative field is of critical importance in endoscopic surgery. During surgery the endoscope lens can get fouled by body fluids (eg, blood), ground substance, rinsing fluid, bone dust, or smoke plumes, resulting in visual impairment. As a result, surgeons spend part of the procedure on intermittent cleaning of the endoscope lens. Current cleaning methods that rely on manual wiping or a lens irrigation system are still far from ideal, leading to longer procedure times, dirtying of the surgical site, and reduced visual acuity, potentially reducing patient safety. With the goal of finding a solution to these issues, a literature review was conducted to identify and categorize existing techniques capable of achieving optically clean surfaces, and to show which techniques can potentially be implemented in surgical practice. The review found that the most promising method for achieving surface cleanliness consists of a hybrid solution, namely, that of a hydrophilic or hydrophobic coating on the endoscope lens and the use of the existing lens irrigation system. ...
Journal article (2017) - E. A. Arkenbout, L. van den Haak, Maxime Penning, Ellemijn Rog, Amanda Vierwind, L.E. van Capelle, F. W. Jansen, J. C F de Winter
Laparoscopic hysterectomy is a procedure that involves the removal of the uterus through an abdominal keyhole incision. Morcellators have been specifically designed for this task, but their use has been discouraged by the food and drug administration (FDA) since November 2014 because of risks of cancerous tissue spread. The use of laparoscopic bags to catch and contain tissue debris has been suggested, but this does not solve the root cause of tissue spread. The fundamental problem lies in the tendency of the tissue mass outside the morcellation tube to rotate along with the cutting blade, causing tissue to be spread through the abdomen. This paper presents a bio-inspired concept that constrains the tissue mass in the advent of its rotation in order to improve the overall morcellation efficacy and reduce tissue spread. A design of gripping teeth integrated into the inner diameter of the morcellation tube is proposed. Various tooth geometries were developed and evaluated through an iterative process in order to maximize the gripping forces of these teeth. The maximum gripping force was determined through the measurement of force-displacement curves during the gripping of gelatin and bovine tissue samples. The results indicate that a tooth ring with a diameter of 15mm can provide a torque resistance of 1.9 Ncm. Finally, a full morcellation instrument concept design is provided. ...
Journal article (2015) - EA Arkenbout, JCF de Winter, P Breedveld
Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman filter. The Nimble VR and filter output were compared using measurements performed on (1) a wooden hand model placed in various static postures and orientations; and (2) three differently sized human hands during active finger flexions. Precision and accuracy of joint angle estimates as a function of hand posture and orientation were determined. Moreover, in light of possible self-occlusions of the fingers in the Kinect camera images, data completeness was assessed. Results showed that the integration of the Data Glove through the Kalman filter provided for the proximal interphalangeal (PIP) joints of the fingers a substantial improvement of 79% in precision, from 2.2 deg to 0.9 deg. Moreover, a moderate improvement of 31% in accuracy (being the mean angular deviation from the true joint angle) was established, from 24 deg to 17 deg. The metacarpophalangeal (MCP) joint was relatively unaffected by the Kalman filter. Moreover, the Data Glove increased data completeness, thus providing a substantial advantage over the sole use of the Nimble VR system. ...