Biofilm characteristics, membrane performance and cleanability

Journal article (2019) - N. M. Farhat, L. Javier, M. C.M. Van Loosdrecht, J. C. Kruithof, J. S. Vrouwenvelder
Biofouling severely impacts operational performance of membrane systems increasing the cost of water production. Understanding the effect of critical parameters of feed water such as biodegradable substrate concentration on the developed biofilm characteristics enables development of more effective biofouling control strategies. In this study, the effect of substrate concentration on the biofilm characteristics was examined using membrane fouling simulators (MFSs). A feed channel pressure drop (PD) increase of 200 mbar was used as a benchmark to study the developed biofilm. The amount and characteristics of the formed biofilm were analysed in relation to membrane performance indicators: feed channel pressure drop and permeate flux. The effect of the characteristics of the biofilm developed at three substrate concentrations on the removal efficiency of the different biofilms was evaluated applying acid/base cleaning. Results showed that a higher feed water substrate concentration caused a higher biomass amount, a faster PD increase, but a lower permeate flux decline. The permeate flux decline was affected by the spatial location and the physical characteristics of the biofilm rather than the total amount of biofilm. The slower growing biofilm developed at the lowest substrate concentration was harder to remove by NaOH/HCl cleanings than the biofilm developed at the higher substrate concentrations. Effective biofilm removal is essential to prevent a fast biofilm regrowth after cleaning. While substrate limitation is a generally accepted biofouling control strategy delaying biofouling, development of advanced cleaning methods to remove biofilms formed under substrate limited conditions is of paramount importance. ...
Journal article (2018) - H. Sanawar, I. Pinel, N. M. Farhat, Sz S. Bucs, J. Zlopasa, J. C. Kruithof, G. J. Witkamp, M. C.M. van Loosdrecht, J. S. Vrouwenvelder
Chemical cleaning is routinely performed in reverse osmosis (RO) plants for the regeneration of RO membranes that suffer from biofouling problems. The potential of urea as a chaotropic agent to enhance the solubilization of biofilm proteins has been reported briefly in the literature. In this paper the efficiency of urea cleaning for RO membrane systems has been compared to conventionally applied acid/alkali treatment. Preliminary assessment confirmed that urea did not damage the RO polyamide membranes and that the membrane cleaning efficiency increased with increasing concentrations of urea and temperature. Accelerated biofilm formation was carried out in membrane fouling simulators which were subsequently cleaned with (i) 0.01M sodium hydroxide (NaOH) and 0.1M hydrochloric acid (HCl) (typically applied in industry), (ii) urea (CO(NH 2 ) 2 ) and hydrochloric acid, or (iii) urea only (1340 g/L water ). The pressure drop over the flow channel was used to evaluate the efficiency of the applied chemical cleanings. Biomass removal was evaluated by measuring chemical oxygen demand (COD), adenosine triphosphate (ATP), protein, and carbohydrate content from the membrane and spacer surfaces after cleaning. In addition to protein and carbohydrate quantification of the extracellular polymeric substances (EPS), fluorescence excitation−emission matrix (FEEM) spectroscopy was used to distinguish the difference in organic matter of the remaining biomass to assess biofilm solubilization efficacy of the different cleaning agents. Results indicated that two-stage CO(NH 2 ) 2 /HCl cleaning was as effective as cleaning with NaOH/HCl in terms of restoring the feed channel pressure drop (>70% pressure drop decrease). One-stage cleaning with urea only was not as effective indicating the importance of the second-stage low pH acid cleaning in weakening the biofilm matrix. All three chemical cleaning protocols were equally effective in reducing the concentration of predominant EPS components protein and carbohydrate (>50% reduction in concentrations). However, urea-based cleaning strategies were more effective in solubilizing protein-like matter and tyrosine-containing proteins. Furthermore, ATP measurements showed that biomass inactivation was up to two-fold greater after treatment with urea-based chemical cleanings compared to the conventional acid/alkali treatment. The applicability of urea as an alternative, economical, eco-friendly and effective chemical cleaning agent for the control of biological fouling was successfully demonstrated. ...
Book (2018) - Mark C.M. van Loosdrecht, J. C. Kruithof, Szilard Bucs, Hans Vrouwenvelder

Quantification methods and impact on hydraulic characterization

Journal article (2017) - A Siddiqui, S Lehmann, V. Haaksman, J. Ogier, Carsten Schellenberg, M. C.M. van Loosdrecht, J. C. Kruithof, J. S. Vrouwenvelder
The porosity of spacer-filled feed channels influences the hydrodynamics of spiral-wound membrane systems and impacts the overall performance of the system. Therefore, an exact measurement and a detailed understanding of the impact of the feed channel porosity is required to understand and improve the hydrodynamics of spiral-wound membrane systems applied for desalination and wastewater reuse. The objectives of this study were to assess the accuracy of porosity measurement techniques for feed spacers differing in geometry and thickness and the consequences of using an inaccurate method on hydrodynamic predictions, which may affect permeate production. Six techniques were applied to measure the porosity namely, three volumetric techniques based on spacer strand count together with a cuboidal (SC), cylindrical (VCC) and ellipsoidal volume calculation (VCE) and three independent techniques based on volume displacement (VD), weight and density (WD) and computed tomography (CT) scanning. The CT method was introduced as an alternative for the other five already existing and applied methods in practice. Six feed spacers used for the porosity measurement differed in filament thickness, angle between the filaments and mesh-size. The results of the studies showed differences between the porosities, measured by the six methods. The results of the microscopic techniques SC, VCC and VCE deviated significantly from measurements by VD, WD and CT, which showed similar porosity values for all spacer types. Depending on the maximum deviation of the porosity measurement techniques from −6% to +6%, (i) the linear velocity deviations were −5.6% and +6.4% respectively and (ii) the pressure drop deviations were −31% and +43% respectively, illustrating the importance of an accurate porosity measurement. Because of the accuracy and standard deviation, the VD and WD method should be applied for the porosity determination of spacer-filled channels, while the CT method is recommended for numerical modelling purposes. The porosity has a linear relationship with the flow velocity and a superlinear effect on the pressure drop. Accurate porosity data are essential to evaluate feed spacer performance in spiral-wound membrane systems. Porosity of spacer-filled feed channels has a strong impact on membrane performance and biofouling impact. ...
Journal article (2017) - A. Siddiqui, S. Lehmann, J. S. Vrouwenvelder, Sz S. Bucs, M. Fresquet, L. Fel, E. I E C Prest, J. Ogier, C. Schellenberg, M. C M van Loosdrecht, J. C. Kruithof
Feed spacers are an essential part of spiral-wound reverse osmosis (RO) and nanofiltration (NF) membrane modules. Geometric modification of feed spacers is a potential option to reduce the impact of biofouling on the performance of membrane systems. The objective of this study was to evaluate the biofouling potential of two commercially available reference feed spacers and four modified feed spacers. The spacers were compared on hydraulic characterization and in biofouling studies with membrane fouling simulators (MFSs). The virgin feed spacer was characterized hydraulically by their resistance, measured in terms of feed channel pressure drop, performed by operating MFSs at varying feed water flow rates. Short-term (9 days) biofouling studies were carried out with nutrient dosage to the MFS feed water to accelerate the biofouling rate. Long-term (96 days) biofouling studies were done without nutrient dosage to the MFS feed water. Feed channel pressure drop was monitored and accumulation of active biomass was quantified by adenosine tri phosphate (ATP) determination. The six feed spacers were ranked on pressure drop (hydraulic characterization) and on biofouling impact (biofouling studies). Significantly different trends in hydraulic resistance and biofouling impact for the six feed spacers were observed. The same ranking for biofouling impact on the feed spacers was found for the (i) short-term biofouling study with nutrient dosage and the (ii) long-term biofouling study without nutrient dosage. The ranking for hydraulic resistance for six virgin feed spacers differed significantly from the ranking of the biofouling impact, indicating that hydraulic resistance of clean feed spacers does not predict the hydraulic resistance of biofouled feed spacers. Better geometric design of feed spacers can be a suitable approach to minimize impact of biofouling in spiral wound membrane systems. ...
Journal article (2017) - A Siddiqui, I. Pinel, E. I. Prest, Sz S. Bucs, M. C.M. van Loosdrecht, J. C. Kruithof, J. S. Vrouwenvelder
Biocides may be used to control biofouling in spiral-wound reverse osmosis (RO) and nanofiltration (NF) systems. The objective of this study was to investigate the effect of biocide 2,2-dibromo-3-ni-trilopropionamide (DBNPA) dosage on biofouling control. Preventive biofouling control was studied applying a continuous dosage of substrate (0.5 mg/L) and DBNPA (1 mg/L). Curative biofouling control was studied on pre-grown biofilms, once again applying a continuous dosage of substrate (0.5 mg acetate C/L) and DBNPA (1 and 20 mg/L). Biofouling studies were performed in membrane fouling simulators (MFSs) supplied with biodegradable substrate and DBNPA. The pressure drop was monitored in time and at the end of the study, the accumulated biomass in MFS was quantified by adenosine triphosphate (ATP) and total organic carbon (TOC) analysis. Continuous dosage of DBNPA (1 mg/L) prevented pressure drop increase and biofilm accumulation in the MFSs during a run time of 7 d, showing that biofouling can be managed by preventive DBNPA dosage. For biofouled systems, continuous dosage of DBNPA (1 and 20 mg/L) inactivated the accumulated biomass but did not restore the original pressure drop and did not remove the accumulated inactive cells and extracellular polymeric substances (EPS), indicating DBNPA dosage is not suitable for curative biofouling control. ...
Journal article (2017) - H. Sanawar, A. Siddiqui, Sz S. Bucs, N. M. Farhat, M. C.M. van Loosdrecht, J. C. Kruithof, J. S. Vrouwenvelder
Biofouling studies addressing biofouling control are mostly executed in short-term studies. It is unclear whether data collected from these experiments are representative for long-term biofouling as occurring in full-scale membrane systems. This study investigated whether short-term biofouling studies accelerated by biodegradable nutrient dosage to feed water were predictive for long-term biofouling development without nutrient dosage. Since the presence of a feed spacer has an strong effect on the degree of biofouling, this study employed six geometrically different feed spacers. Membrane fouling simulators (MFSs) were operated with the same (i) membrane, (ii) feed flow and (iii) feed water, but with feed spacers varying in geometry. For the short-term experiment, biofilm formation was enhanced by nutrient dosage to the MFS feed water, whereas no nutrient dosage was applied in the long-term experiment. Pressure drop development was monitored to characterize the extent of biofouling, while the accumulated viable biomass content at the end of the experimental run was quantified by adenosine triphosphate (ATP) measurements. Impact of feed spacer geometry on biofouling was compared for the short-term and long-term biofouling study. The results of the study revealed that the feed spacers exhibited the same biofouling behavior for (i) the short-term (9-d) study with nutrient dosage and (ii) the long-term (96-d) study without nutrient dosage. For the six different feed spacers, the accumulated viable biomass content (pg ATP.cm–2) was roughly the same, but the biofouling impact in terms of pressure drop increase in time was significantly different. The biofouling impact ranking of the six feed spacers was the same for the short-term and long-term biofouling studies. Therefore, it can be concluded that short-term accelerated biofouling studies in MFSs are a representative and suitable approach for the prediction of biofouling in membrane filtration systems after long-term operation. ...
Book chapter (2016) - Hans Vrouwenvelder, C Dreszer, R. Valadares Linares, J. C. Kruithof, C Mayer, HC Flemming
Journal article (2013) - C Dreszer, J. S. Vrouwenvelder, A. H. Paulitsch-Fuchs, A. Zwijnenburg, J. C. Kruithof, H. C. Flemming
Biofilms may interfere with membrane performance in at least three ways: (i) increase of the transmembrane pressure drop, (ii) increase of feed channel (feed-concentrate) pressure drop, and (iii) increase of transmembrane passage. Given the relevance of biofouling, it is surprising how few data exist about the hydraulic resistance of biofilms that may affect the transmembrane pressure drop and membrane passage. In this study, biofilms were generated in a lab scale cross flow microfiltration system at two fluxes (20 and 100Lm-2h-1) and constant cross flow (0.1ms-1). As a nutrient source, acetate was added (1.0mgL-1 acetate C) besides a control without nutrient supply. A microfiltration (MF) membrane was chosen because the MF membrane resistance is very low compared to the expected biofilm resistance and, thus, biofilm resistance can be determined accurately. Transmembrane pressure drop was monitored. As biofilm parameters, thickness, total cell number, TOC, and extracellular polymeric substances (EPS) were determined, it was demonstrated that no internal membrane fouling occurred and that the fouling layer actually consisted of a grown biofilm and was not a filter cake of accumulated bacterial cells. At 20Lm-2h-1 flux with a nutrient dosage of 1mgL-1 acetate C, the resistance after 4 days reached a value of 6×1012m-1. At 100Lm-2h-1 flux under the same conditions, the resistance was 5×1013m-1. No correlation of biofilm resistance to biofilm thickness was found; Biofilms with similar thickness could have different resistance depending on the applied flux. The cell number in biofilms was between 4×107 and 5×108 cellscm-2. At this number, bacterial cells make up less than a half percent of the overall biofilm volume and therefore did not hamper the water flow through the biofilm significantly. A flux of 100Lm-2h-1 with nutrient supply caused higher cell numbers, more biomass, and higher biofilm resistance than a flux of 20Lm-2h-1. However, the biofilm thickness after 4 days at a flux of 100Lm-2h-1 (97μm) was in the same order of magnitude as the thickness of a biofilm at a flux of 20Lm-2h-1 (114μm). An increase of flux caused an increased biofilm resistance while a decrease of flux caused a decreased resistance. The effect was reversible. It is suggested that the biofilm resistance is mainly attributed to EPS, probably due to the tortuosity ("hair-in-sink-effect") of the biopolymers to water molecules travelling across the biofilm. The data show clearly that biofilm resistance (6×1012m-1) was high compared to the intrinsic resistance of the employed MF membrane (5×1011m-1). However, in nanofiltration (intrinsic membrane resistance ca. 2×1013m-1) and reverse osmosis membranes (intrinsic resistance ca. 9×1013m-1), the biofilm will not contribute significantly to the overall resistance. ...