Implant infections caused by Staphylococcus aureus are difficult to treat due to biofilm formation, which complicates surgical and antibiotic treatment. We introduce an alternative approach using monoclonal antibodies (mAbs) targeting S. aureus and provide evidence of the specificity and biodistribution of S.-aureus-targeting antibodies in a mouse implant infection model. The monoclonal antibody 4497-IgG1 targeting wall teichoic acid in S. aureus was labeled with indium-111 using CHX-A”-DTPA as a chelator. Single Photon Emission Computed Tomography/computed tomographyscans were performed at 24, 72 and 120 h after administration of the 111In-4497 mAb in Balb/cAnNCrl mice with a subcutaneous implant that was pre-colonized with S. aureus biofilm. The biodistribution of this labelled antibody over various organs was visualized and quantified using SPECT/CT imaging, and was compared to the uptake at the target tissue with the implanted infection. Uptake of the 111In-4497 mAbs at the infected implant gradually increased from 8.34 %ID/cm3 at 24 h to 9.22 %ID/cm3 at 120 h. Uptake at the heart/blood pool decreased over time from 11.60 to 7.58 %ID/cm3, whereas the uptake in the other organs decreased from 7.26 to less than 4.66 %ID/cm3 at 120 h. The effective half-life of 111In-4497 mAbs was determined to be 59 h. In conclusion, 111In-4497 mAbs were found to specifically detect S. aureus and its biofilm with excellent and prolonged accumulation at the site of the colonized implant. Therefore, it has the potential to serve as a drug delivery system for the diagnostic and bactericidal treatment of biofilm.
Despite improvements in small animal PET instruments, many tracers cannot be imaged at sufficiently high resolutions due to positron range, while multi-tracer PET is hampered by the fact that all annihilation photons have equal energies. Here we realize multi-isotope and sub-mm resolution PET of isotopes with several mm positron range by utilizing prompt gamma photons that are commonly neglected. A PET-SPECT-CT scanner (VECTor/CT, MILabs, The Netherlands) equipped with a high-energy cluster-pinhole collimator was used to image 124I and a mix of 124I and 18F in phantoms and mice. In addition to positrons (mean range 3.4 mm) 124I emits large amounts of 603 keV prompt gammas that - aided by excellent energy discrimination of NaI - were selected to reconstruct 124I images that are unaffected by positron range. Photons detected in the 511 keV window were used to reconstruct 18F images. Images were reconstructed iteratively using an energy dependent matrix for each isotope. Correction of 18F images for contamination with 124I annihilation photons was performed by Monte Carlo based range modelling and scaling of the 124I prompt gamma image before subtracting it from the 18F image. Additionally, prompt gamma imaging was tested for 89Zr that emits very high-energy prompts (909 keV). In Derenzo resolution phantoms 0.75 mm rods were clearly discernable for 124I, 89Zr and for simultaneously acquired 124I and 18F imaging. Image quantification in phantoms with reservoirs filled with both 124I and 18F showed excellent separation of isotopes and high quantitative accuracy. Mouse imaging showed uptake of 124I in tiny thyroid parts and simultaneously injected 18F-NaF in bone structures. The ability to obtain PET images at sub-mm resolution both for isotopes with several mm positron range and for multi-isotope PET adds to many other unique capabilities of VECTor's clustered pinhole imaging, including simultaneous sub-mm PET-SPECT and theranostic high energy SPECT.
EXIRAD-3D
Fast automated three-dimensional autoradiography
Introduction: Autoradiography is an established technique for high-resolution imaging of radiolabelled molecules in biological tissue slices. Unfortunately, creating a 3D image from a set of these 2D images is extremely time-consuming and error-prone. MicroSPECT systems provide such 3D images but have a low resolution. Here we present EXIRAD-3D, a fast automated method as an alternative for 3D autoradiography from coupes based on ultra-high resolution microSPECT technology. Methods: EXIRAD-3D uses a very small bore focusing multi-pinhole collimator mounted in a SPECT system with stationary detectors (U-SPECT/CT, MILabs B.V. The Netherlands) using a sample holder with integrated tissue cooling to avoid activity leaking or tissue deformation during the scan. The system performance was experimentally evaluated using various phantoms and tissue samples of animals in vivo injected with technetium-99m and iodine-123. Results: The reconstructed spatial resolution obtained with a Derenzo hot rod phantom was 120 μm (or 1.7 nl). The voxel values of a syringe phantom image appear to be uniform and scale linearly with activity. Uptake in tiny details of the mouse knee joint, thyroid, and kidney could be clearly visualized. Conclusion: EXIRAD-3D opens up the possibility for fast and quantitative 3D imaging of radiolabelled molecules at a resolution far better than in vivo microSPECT and saves tremendous amounts of work compared to obtaining 3D data from a set of 2D autoradiographs. Advances in knowledge and implications for patient care: EXIRAD-3D offers superior image resolution over microSPECT, and it can be a very efficient alternative for autoradiography in pharmaceutical and biological studies.