ML

Marnix G.E.H. Lam

info

Please Note

4 records found

Journal article (2026) - F. Ruben H.A. Nurmohamed, Kevin J.H. Allen, Harrie Weinans, Ekaterina Dadachova, Bart C.H.van der Wal, Connor Frank, Mackenzie E. Malo, J. Fred F.Hooning van Duyvenbode, Berend van der Wildt, Alex J. Poot, Marnix G.E.H. Lam, Jos A.G.van Strijp, H. Charles Vogely
Background: Early postoperative implant infections are difficult to diagnose due to overlapping symptoms with inflammation. However, prompt surgical intervention for an implant infection can prevent the need for repeated surgeries and improve the overall success of the treatment and preserving the implant. The primary objective of this study was to assess the sensitivity and specificity of a novel immuno-PET radiotracer for detecting Staphylococcus aureus bacteria and their biofilms in a preclinical rat model. Results: An antibody against wall teichoic acid a common surface component of S. aureus, was labeled with Zirconium-89- as the PET tracer. Wistar Han rats underwent surgery with a S. aureus-related biofilm-infected femoral implant on one side and a sterile femoral implant on the contralateral side. The diagnostic efficacy of this imaging modality was compared with clinically established nuclear imaging techniques for implant infections, including [99mTc]Tc-MDP SPECT/CT, [18F]FDG PET/CT, and [18F]NaF PET/CT. Furthermore, co-injection of unlabeled (“cold”) antibodies was performed to evaluate their impact on biodistribution. All animals with a biofilm-associated femoral implant infection showed significantly higher uptake of the novel ImmunoPET tracer in the infected side compared to the sterile side throughout the 13-day postoperative study duration. A dose-dependent increase in tracer accumulation was observed with co-injection of cold antibody, suggesting its potential to improve biodistribution. Conclusions: ImmunoPET with Zirconium-89-labeled antibodies specific for wall teichoic acid antigen demonstrates sensitive and specific diagnostic capabilities compared to conventional nuclear imaging modalities, offering a promising tool for early detection of postoperative chronic low-grade infections and septic implant loosening. ...
Journal article (2025) - F. Ruben H.A. Nurmohamed, Kevin J.H. Allen, H. Charles Vogely, Harrie Weinans, Ekaterina Dadachova, Bart C.H. van der Wal, Mackenzie E. Malo, Connor Frank, J. Fred F.Hooning van Duvenbode, Berend van der Wildt, Alex J. Poot, Marnix G.E.H. Lam, Jos A.G. van Strijp, Peter G.J. Nikkels
Background: the primary challenge with implant infections is the formation of biofilm, which harbors dormant bacteria that reduce the effectiveness of antibiotics and amplify antibiotic resistance, exacerbating the global antimicrobial resistance crisis. A potential novel treatment strategy is radioimmunotherapy, which uses antibodies linked to radioisotopes to deliver targeted radiation to the bacteria and biofilm. We describe the first in vivo use of targeted radiation therapy, employing Actinium-225 (α-radiation) and Lutetium-177 (β-radiation) labeled antibodies to treat a Staphylococcus aureus biofilm-associated intramedullary implant infection. Untargeted radiation in the form of unbound radionuclide treatment was also evaluated. Methods: to assess therapeutic efficacy, bacterial counts were performed on implant and surrounding bone after seven days of follow-up. Biodistribution was evaluated using SPECT/CT and ex vivo gamma counting. Results: radioimmunotherapy using an antibody against wall teichoic acid which was labeled with Actinium-225 and Lutetium-177 achieved bacterial reductions between 45% and 93% on the implant and surrounding bone. Surprisingly, a similar antimicrobial effect was observed with unbound Actinium-225 treatment reducing the bacterial load by 80% on the implant and 98% in the surrounding bone. Indications of maximum tolerated dose (MTD) with Lutetium-177 labeled antibodies were observed through hepatic and renal function evaluations. Conclusions: These results should be interpreted in the context of the study’s constraints, particularly the limited animal sample size. Nonetheless, the results suggest that in vivo applied radiation may help reduce a biofilm-associated infection at the implant site as well as in the surrounding bone. These findings encourage further investigation into the use of targeted and non-targeted radiation, potentially combined with antibiotics, to develop effective strategies for eradicating biofilm-associated implant infections. ...
Journal article (2024) - Zijian Ye, Berend van der Wildt, Alex J. Poot, F. Ruben H.A. Nurmohamed, J. Fred F.Hooning van Duyvenbode, Jos van Strijp, H. Charles Vogely, Marnix G.E.H. Lam, Ekaterina Dadachova, Harrie Weinans, Bart C.H. van der Wal
Background: Addressing prosthetic joint infections poses a significant challenge within orthopedic surgery, marked by elevated morbidity and mortality rates. The presence of biofilms and infections attributed to Staphylococcus aureus (S. aureus) further complicates the scenario. Objective: To investigate the potential of radioimmunotherapy as an innovative intervention to tackle biofilm-associated infections. Methods: Our methodology involved employing specific monoclonal antibodies 4497-IgG1, designed for targeting wall teichoic acids found on S. aureus and its biofilm. These antibodies were linked with radionuclides actinium-225 (225Ac) and lutetium-177 (177Lu) using DOTA as a chelator. Following this, we evaluated the susceptibility of S. aureus and its biofilm to radioimmunotherapy in vitro, assessing bacterial viability and metabolic activity via colony-forming unit enumeration and xylenol tetrazolium assays. Results: Both [225Ac]4497-IgG1 and [177Lu]4497-IgG1 exhibited a noteworthy dose-dependent reduction in S. aureus in planktonic cultures and biofilms over a 96-h exposure period, compared to non-specific antibody control groups. Specifically, doses of 7.4 kBq and 7.4 MBq of [225Ac]4497-IgG1 and [177Lu]4497-IgG1 resulted in a four-log reduction in planktonic bacterial counts. Within biofilms, 14.8 kBq of [225Ac]4497-IgG1 and 14.8 Mbq [177Lu]4497-IgG1 led to reductions of two and four logs, respectively. Conclusion: Our findings underscore the effectiveness of [225Ac]4497-IgG1 and [177Lu]4497-IgG1 antibodies in exerting dose-dependent bactericidal effects against planktonic S. aureus and biofilms in vitro. This suggests that radioimmunotherapy might serve as a promising targeted treatment approach for combating S. aureus and its biofilm. ...
Journal article (2023) - Bruce van Dijk, J. Fred F. Hooning van Duyvenbode, More authors..., Lisanne de Vor, F. Ruben H.A. Nurmohamed, Marnix G.E.H. Lam, Alex J. Poot, Ruud M. Ramakers, Sofia Koustoulidou, Freek J. Beekman, Harrie Weinans
Implant infections caused by Staphylococcus aureus are difficult to treat due to biofilm formation, which complicates surgical and antibiotic treatment. We introduce an alternative approach using monoclonal antibodies (mAbs) targeting S. aureus and provide evidence of the specificity and biodistribution of S.-aureus-targeting antibodies in a mouse implant infection model. The monoclonal antibody 4497-IgG1 targeting wall teichoic acid in S. aureus was labeled with indium-111 using CHX-A”-DTPA as a chelator. Single Photon Emission Computed Tomography/computed tomographyscans were performed at 24, 72 and 120 h after administration of the 111In-4497 mAb in Balb/cAnNCrl mice with a subcutaneous implant that was pre-colonized with S. aureus biofilm. The biodistribution of this labelled antibody over various organs was visualized and quantified using SPECT/CT imaging, and was compared to the uptake at the target tissue with the implanted infection. Uptake of the 111In-4497 mAbs at the infected implant gradually increased from 8.34 %ID/cm3 at 24 h to 9.22 %ID/cm3 at 120 h. Uptake at the heart/blood pool decreased over time from 11.60 to 7.58 %ID/cm3, whereas the uptake in the other organs decreased from 7.26 to less than 4.66 %ID/cm3 at 120 h. The effective half-life of 111In-4497 mAbs was determined to be 59 h. In conclusion, 111In-4497 mAbs were found to specifically detect S. aureus and its biofilm with excellent and prolonged accumulation at the site of the colonized implant. Therefore, it has the potential to serve as a drug delivery system for the diagnostic and bactericidal treatment of biofilm. ...