LK

Lukas C. Kapitein

info

Please Note

6 records found

Journal article (2026) - Josiah B. Passmore, Alfredo Rates, Carlas S. Smith, Ihor Smal, Lukas C. Kapitein, Jakob Schröder, Menno T.P. van Laarhoven, Vincent J.W. Hellebrekers, Henrik G. van Hoef, Antonius J.M. Geurts, Wendy van Straaten, Wilco Nijenhuis, Florian Berger
Smart microscopy is transforming biological imaging by integrating real-time analysis with adaptive acquisition to enhance imaging efficiency. Whereas many emerging implementations are event-driven and focus on on-demand data acquisition to reduce phototoxicity, we here present ‘outcome-driven’ microscopy, a framework combining smart microscopy with optogenetics to control cell biological processes and achieve predefined outcomes. We validate this approach using light-based control of cell migration and nucleocytoplasmic transport, demonstrating robust spatiotemporal control of cellular behaviour in single cells and in cell populations. ...

Single-objective lens inclined light sheet localization microscopy

Journal article (2022) - Shih Te Hung, Jelmer Cnossen, Daniel Fan, Marijn Siemons, Daphne Jurriens, Kristin Grusmayer, Oleg Soloviev, Lukas C. Kapitein, Carlas S. Smith
High-NA light sheet illumination can improve the resolution of single-molecule localization microscopy (SMLM) by reducing the background fluorescence. These approaches currently require custom-made sample holders or additional specialized objectives, which makes the sample mounting or the optical system complex and therefore reduces the usability of these approaches. Here, we developed a single-objective lens-inclined light sheet microscope (SOLEIL) that is capable of 2D and 3D SMLM in thick samples. SOLEIL combines oblique illumination with point spread function PSF engineering to enable dSTORM imaging in a wide variety of samples. SOLEIL is compatible with standard sample holders and off-the-shelve optics and standard high NA objectives. To accomplish optimal optical sectioning we show that there is an ideal oblique angle and sheet thickness. Furthermore, to show what optical sectioning delivers for SMLM we benchmark SOLEIL against widefield and HILO microscopy with several biological samples. SOLEIL delivers in 15 μm thick Caco2-BBE cells a 374% higher intensity to background ratio and a 54% improvement in the estimated CRLB compared to widefield illumination, and a 184% higher intensity to background ratio and a 20% improvement in the estimated CRLB compared to HILO illumination. ...
Journal article (2022) - Marijn E. Siemons, Lukas C. Kapitein, Sjoerd Stallinga
Single-molecule localization microscopy has developed into a widely used technique to overcome the diffraction limit and enables 3D localization of single-emitters with nanometer precision. A widely used method to enable 3D encoding is to use a cylindrical lens or a phase mask to engineer the point spread function (PSF). The performance of these PSFs is often assessed by comparing the precision they achieve, ignoring accuracy. Nonetheless, accurate localization is required in many applications, such as multi-plane imaging, measuring and modelling of physical processes based on volumetric data, and 3D particle averaging. However, there are PSF model mismatches in the localization schemes due to how reference PSFs are obtained, look-up-tables are created, or spots are fitted. Currently there is little insight in how these model mismatches give rise to systematic axial localization errors, how large these errors are, and how to mitigate them. In this theoretical and simulation work we use a vector PSF model, which incorporates super-critical angle fluorescence (SAF) and the appropriate aplanatic correction factor, to analyze the errors in z-localization. We introduce theory for defining the focal plane in SAF conditions and analyze the predicted axial errors for an astigmatic PSF, double-helix PSF, and saddle-point PSF. These simulations indicate that the absolute axial biases can be as large as 140 nm, 250 nm, and 120 nm for the astigmatic, saddle-point, and double-helix PSF respectively, with relative errors of more than 50%. Finally, we discuss potential experimental methods to verify these findings and propose a workflow to mitigate these effects. ...
Journal article (2022) - S. Hung, Arnau Llobet Rosell, Daphne Jurriens, O.A. Soloviev, Lukas C. Kapitein, K.S. Grußmayer, Lukas J. Neukomm, M.H.G. Verhaegen, C.S. Smith
Single-molecule localization microscopy (SMLM) enables the high-resolution visualization of organelle structures and the precise localization of individual proteins. However, the expected resolution is not achieved in tissue as the imaging conditions deteriorate. Sample-induced aberrations distort the point spread function (PSF), and high background fluorescence decreases the localization precision. Here, we synergistically combine sensorless adaptive optics (AO), in-situ 3D-PSF calibration, and a single-objective lens inclined light sheet microscope (SOLEIL), termed (AO-SOLEIL), to mitigate deep tissue-induced deteriorations. We apply AO-SOLEIL on several dSTORM samples including brains of adult Drosophila. We observed a 2x improvement in the estimated axial localization precision with respect to widefield without aberration correction while we used synergistic solution. AO-SOLEIL enhances the overall imaging resolution and further facilitates the visualization of sub-cellular structures in tissue. ...
Journal article (2018) - Amol Aher, Maurits Kok, Michel O. Steinmetz, Marileen Dogterom, Anna Akhmanova, Ashwani Sharma, Ankit Rai, Natacha Olieric, Ruddi Rodriguez-Garcia, Eugene A. Katrukha, Tobias Weinert, Vincent Olieric, Lukas C. Kapitein
The dynamic instability of microtubules plays a key role in controlling their organization and function, but the cellular mechanisms regulating this process are poorly understood. Here, we show that cytoplasmic linker-associated proteins (CLASPs) suppress transitions from microtubule growth to shortening, termed catastrophes, including those induced by microtubule-destabilizing agents and physical barriers. Mammalian CLASPs encompass three TOG-like domains, TOG1, TOG2, and TOG3, none of which bind to free tubulin. TOG2 is essential for catastrophe suppression, whereas TOG3 mildly enhances rescues but cannot suppress catastrophes. These functions are inhibited by the C-terminal domain of CLASP2, while the TOG1 domain can release this auto-inhibition. TOG2 fused to a positively charged microtubule-binding peptide autonomously accumulates at growing but not shrinking ends, suppresses catastrophes, and stimulates rescues. CLASPs suppress catastrophes by stabilizing growing microtubule ends, including incomplete ones, preventing their depolymerization and promoting their recovery into complete tubes. TOG2 domain is the key determinant of these activities. ...

Optical control of microtubule gliding assays

Journal article (2018) - Roderick P. Tas, Chiung Yi Chen, Eugene A. Katrukha, Mathijs Vleugel, Maurits Kok, Marileen Dogterom, Anna Akhmanova, Lukas C. Kapitein
Force generation by molecular motors drives biological processes such as asymmetric cell division and cell migration. Microtubule gliding assays in which surface-immobilized motor proteins drive microtubule propulsion are widely used to study basic motor properties as well as the collective behavior of active self-organized systems. Additionally, these assays can be employed for nanotechnological applications such as analyte detection, biocomputation, and mechanical sensing. While such assays allow tight control over the experimental conditions, spatiotemporal control of force generation has remained underdeveloped. Here we use light-inducible protein-protein interactions to recruit molecular motors to the surface to control microtubule gliding activity in vitro. We show that using these light-inducible interactions, proteins can be recruited to the surface in patterns, reaching a â5-fold enrichment within 6 s upon illumination. Subsequently, proteins are released with a half-life of 13 s when the illumination is stopped. We furthermore demonstrate that light-controlled kinesin recruitment results in reversible activation of microtubule gliding along the surface, enabling efficient control over local microtubule motility. Our approach to locally control force generation offers a way to study the effects of nonuniform pulling forces on different microtubule arrays and also provides novel strategies for local control in nanotechnological applications. ...