The integration of renewable energy sources has significantly impacted power system protection schemes, primarily by increasing short-circuit fault currents, which, in turn, raises the possibility of current transformer (CT) saturation, and by introducing bidirectional fault c ...

Failures of Induction Motors (IMs) can lead to unscheduled downtime and interruption in industry processes. This paper concentrates on the detection of the stator's inter-turn faults which are one of the most frequent causes of failures in IMs. The proposed detection method is ...

Fast internal detection and location in Shunt Ca-pacitor Banks (SCBs) can lead to the prevention of damages to other SCBs' elements and consequently avoid undesirable performance and effects in power system operation. This paper targets the performance of phasor-based algorithms ...
Geomagnetically induced currents (GICs) are referred to the quasi-DC current flows in power networks, driven by complex space weather-related phenomena. Such currents are a potential threat to the power delivery capability of electrical grids. To mitigate the detrimental impacts ...

Solar storms cause disturbances in the Earth's magnetic field, which results in quasi-DC geomagnetically induced currents (GICs) flow in the grounded sections of the system. The flow of GICs in the power system may drive the power transformers to the saturation region. Moreove ...

Vacuum circuit breaker operation causes transient overvoltages that may lead to severe damages to transformer insulation. Since the parameters affecting these overvoltages have stochastic nature, a statistical analysis may provide detailed insight into the overvoltages from the p ...

This paper deals with a fault detection investigation of SCBs, and it is focused on the faulty phase detection and the number of faulty capacitor units. Unlike previous methods, the proposed method provides a relay decision making criterion which determine the faulty capacitor ...

The performance of measurement transformers especially in transient phenomena affects the monitoring, control and protective devices. Coupling capacitor voltage transformer (CCVT) is a measurement transformer that may experience ferroresonance phenomenon due to the presence of ...

HVDC systems under monopolar activity, give rise to flow of earth return currents (ERCs) in nearby AC systems. Medium, and large distribution transformers feeding industries, are of high sensitivity, and because of small ratings are highly prone to failure due to ERCs. Conditi ...