RD

Rick De Klerk

info

Please Note

5 records found

Journal article (2022) - Rick de Klerk, Gabriëlle van der Jagt, Dirkjan Veeger, Lucas van der Woude, Riemer Vegter
The acquisition of daily handrim wheelchair propulsion skill as a multi-layered phenomenon has been studied in the past. Wheelchair racing, however, is considerably different from daily handrim wheelchair propulsion in terms of propulsion technique, as well as the underlying equipment and interface. Understanding wheelchair racing skill acquisition is important from a general motor learning and skill acquisition perspective, but also from a performance and injury prevention perspective. The aim of the current lab-based study was 2-fold: to investigate the evolution of racing wheelchair propulsion skill among a sample of novices and to compare them with an experienced wheelchair racer under similar conditions. A convenience sample of 15 able-bodied novices (8 male, 7 female) completed a standardized three-week submaximal uninstructed practice protocol (3 weeks, 3 sessions per week, 3x4 min per session) in a racing wheelchair on an ergometer. Required wheeling velocity was set at 2.78 m/s (10 km/h) and a rolling friction coefficient of 0.011 (resulting in a mean target load of 21W) was used. For comparison, an experienced T54 Paralympic athlete completed one block of the same protocol. Kinetics, kinematics, and physiological data were captured. A mixed effects regression analysis was used to examine the effect of practice for the novices, while controlling for speed. All participants finished the protocol successfully. However, not all participants were able to achieve the target speed during the first few sessions. Statistically significant improvements over time were found for all outcome measures (i.e., lower metabolic strain, longer push and cycle times) with the exception of mean power and torque per push. The athlete used a significantly greater contact angle and showed “better” outcomes on most metabolic and kinetic variables. While the athlete used a semi-circular propulsion technique, most participants used a double looping over technique. Three weeks of uninstructed wheelchair racing practice significantly improved efficiency and skill among a group of novices, in line with previous studies on daily handrim wheelchair propulsion. The comparison with an experienced athlete expectedly showed that there is still a large performance (and knowledge) gap to be conquered. ...
Journal article (2020) - Rick De Klerk, Riemer J.K. Vegter, Marika T. Leving, Sonja de Groot, DirkJan Veeger, Lucas H.V. van der Woude
The use of a manual wheelchair is critical to 1% of the world's population. Human powered wheeled mobility research has considerably matured, which has led to improved research techniques becoming available over the last decades. To increase the understanding of wheeled mobility performance, monitoring, training, skill acquisition, and optimization of the wheelchair-user interface in rehabilitation, daily life, and sports, further standardization of measurement set-ups and analyses is required. A crucial stepping-stone is the accurate measurement and standardization of external power output (measured in Watts), which is pivotal for the interpretation and comparison of experiments aiming to improve rehabilitation practice, activities of daily living, and adaptive sports. The different methodologies and advantages of accurate power output determination during overground, treadmill, and ergometer-based testing are presented and discussed in detail. Overground propulsion provides the most externally valid mode for testing, but standardization can be troublesome. Treadmill propulsion is mechanically similar to overground propulsion, but turning and accelerating is not possible. An ergometer is the most constrained and standardization is relatively easy. The goal is to stimulate good practice and standardization to facilitate the further development of theory and its application among research facilities and applied clinical and sports sciences around the world. ...
Journal article (2020) - Rick de Klerk, Vera Velhorst, Dirkjan (H E.J.). Veeger, Lucas H.V. van der Woude, Riemer J.K. Vegter
Background: Handrim wheelchair propulsion is often assessed in the laboratory on treadmills (TM) or ergometers (WE), under the assumption that they relate to regular overground (OG) propulsion. However, little is known about the agreement of data obtained from TM, WE, and OG propulsion under standardized conditions. The current study aimed to standardize velocity and power output among these three modalities to consequently compare obtained physiological and biomechanical outcome parameters. Methods: Seventeen able-bodied participants performed two submaximal practice sessions before taking part in a measurement session consisting of 3 × 4 min of submaximal wheelchair propulsion in each of the different modalities. Power output and speed for TM and WE propulsion were matched with OG propulsion, making them (mechanically) as equal as possible. Physiological data and propulsion kinetics were recorded with a spirometer and a 3D measurement wheel, respectively. Results: Agreement among conditions was moderate to good for most outcome variables. However, heart rate was significantly higher in OG propulsion than in the TM condition. Push time and contact angle were smaller and fraction of effective force was higher on the WE when compared to OG/TM propulsion. Participants used a larger cycle time and more negative work per cycle in the OG condition. A continuous analysis using statistical parametric mapping showed a lower torque profile in the start of the push phase for TM propulsion versus OG/WE propulsion. Total force was higher during the start of the push phase for the OG conditions when compared to TM/WE propulsion. Conclusions: Physiological and biomechanical outcomes in general are similar, but possible differences between modalities exist, even after controlling for power output using conventional techniques. Further efforts towards increasing the ecological validity of lab-based equipment is advised and the possible impact of these differences -if at all- in (clinical) practice should be evaluated. ...
Journal article (2020) - R. De Klerk, R. J.K. Vegter, DirkJan Veeger, L.H.V. van der Woude
The measurement of handrim wheelchair propulsion characteristics and performance in the field is complicated due to the non-stationary nature of wheelchair driving. In contrast, the laboratory provides a constrained and standardisable environment to conduct measurements and experiments. Apart from wheelchair treadmills, dynamometers or ergometers for handrim wheelchairs are often custom-made, one-of-a-kind, expensive, and sparsely documented in the research literature. To facilitate standardised and comparable lab-based measurements in research, as well as in clinical settings and adapted sports, a new wheelchair ergometer was developed. The ergometer with instrumented dual rollers allows for the performance analysis of individuals in their personal handrim wheelchair and facilitates capacity assessment, training and skill acquisition in rehabilitation or adapted sports. The ergometer contains two servomotors, one for each rear wheel roller, that allow for the simulation of translational inertia and resistive forces as encountered during wheelchair propulsion based on force input and a simple mechanical model of wheelchair propulsion. A load cell configuration for left and right roller enables the measurement of effective user-generated torque and force on the handrim and the concomitant timing patterns. Preliminary results are discussed. ...

A critical analysis of stationary ergometers

Journal article (2020) - Rick De Klerk, Riemer Jakobs K. Vegter, Vicky L. Goosey-Tolfrey, Barry S. Mason, John P. Lenton, Dirkjan H.E.J. Veeger, L.H.V. van der Woude
There are many ways to simulate handrim wheelchair propulsion in the laboratory. Ideally, these would be able to, at least mechanically, simulate field conditions. This narrative review provides an overview of the lab-based equipment used in published research and critically assesses their ability to simulate and measure wheelchair propulsion performance. A close connection to the field can only be achieved if the instrument can adequately simulate frictional losses and inertia of real-life handrim wheelchair propulsion, while maintaining the ergonomic properties of the wheelchair-user interface. Lab-based testing is either performed on a treadmill or a wheelchair ergometer (WCE). For this study WCEs were divided into three categories: roller, flywheel, and integrated ergometers. In general, treadmills are mechanically realistic, but cannot simulate air drag and acceleration tasks cannot be performed; roller ergometers allow the use of the personal wheelchair, but calibration can be troublesome; flywheel ergometers can be built with commercially-available parts, but inertia is fixed and the personal wheelchair cannot be used; integrated ergometers do not employ the personal wheelchair, but are suited for the implementation of different simulation models and detailed measurements. Lab-based equipment is heterogeneous and there appears to be little consensus on how to simulate field conditions. ...