A Ratiometric Readout Circuit for Thermal-Conductivity-Based Resistive CO₂ Sensors

Journal Article (2016)
Author(s)

Zeyu Cai (TU Delft - Electronic Instrumentation)

Robert Veldhoven (NXP Semiconductors)

A Falepin (NXP Semiconductors)

Hilco Suy (NXP Semiconductors)

E Sterckx (NXP Semiconductors)

C. Bitterlich (BL Environmental Sensors)

K. A.A. Makinwa (TU Delft - Microelectronics)

Michiel A. P. Pertijs (TU Delft - Electronic Instrumentation)

Copyright
© 2016 Z. Cai, Robert H.M. van Veldhoven, A. Falepin, H. Suy, E. Sterckx, C. Bitterlich, K.A.A. Makinwa, M.A.P. Pertijs
DOI related publication
https://doi.org/10.1109/JSSC.2016.2587861
More Info
expand_more
Publication Year
2016
Language
English
Copyright
© 2016 Z. Cai, Robert H.M. van Veldhoven, A. Falepin, H. Suy, E. Sterckx, C. Bitterlich, K.A.A. Makinwa, M.A.P. Pertijs
Issue number
10
Volume number
51
Pages (from-to)
2453‒2474
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This paper reports a readout circuit for a resistive CO2 sensor, which operates by measuring the CO2-dependent thermal conductivity of air. A suspended hot-wire transducer, which acts both as a resistive heater and temperature sensor, exhibits a CO2-dependent heat loss to the surrounding air, allowing CO2 concentration to be derived from its temperature rise and power dissipation. The circuit employs a dual-mode incremental delta-sigma ADC to digitize these parameters relative to those of an identical, but isolated, reference transducer. This ratiometric approach results in a measurement that does not require precision voltage or power references. The readout circuit uses dynamically-swapped transducer pairs to cancel their baseline-resistance, so as to relax the required dynamic range of the ADC. In addition, dynamic element matching (DEM) is used to bias the transducer pairs at an accurate current ratio, making the measurement insensitive to the precise value of the bias current. The readout circuit has been implemented in a standard 0.16 μm CMOS technology. With commercial resistive micro-heaters, a CO2 sensing resolution of about 200 ppm (1σ) was achieved in a measurement time of 30 s. Similar results were obtained with CMOS-compatible tungsten-wire transducers, paving the way for fully-integrated CO2 sensors for air-quality monitoring.