Dynamic optimization for minimal HVAC demand with latent heat storage, heat recovery, natural ventilation, and solar shadings

Journal Article (2023)
Author(s)

L.A. de Araujo Passos (TU Delft - Team Bart De Schutter)

P.J.W. van den Engel (TU Delft - Environmental & Climate Design)

S Baldi (Southeast University, TU Delft - Team Bart De Schutter)

Bart De Schutter (TU Delft - Delft Center for Systems and Control)

Research Group
Team Bart De Schutter
Copyright
© 2023 L.A. de Araujo Passos, P.J.W. van den Engel, S. Baldi, B.H.K. De Schutter
DOI related publication
https://doi.org/10.1016/j.enconman.2022.116573
More Info
expand_more
Publication Year
2023
Language
English
Copyright
© 2023 L.A. de Araujo Passos, P.J.W. van den Engel, S. Baldi, B.H.K. De Schutter
Research Group
Team Bart De Schutter
Bibliographical Note
Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.@en
Volume number
276
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Satisfying thermal comfort in indoor spaces is still a challenge in terms of energy saving, and several HVAC (Heating, Ventilation, and Air-Conditioning) systems have been proposed for this purpose. This paper conducts an analysis to evaluate and optimize the long-term operation of a novel HVAC system installed at The Green Village, a living lab in Delft, the Netherlands. This system comprises all-glass facades with steerable solar shades, sky windows, a climate tower equipped with Phase-Change Material (PCM), a heat recovery unit, and a heat pump. The current analysis draws on transient modeling to predict the system's behavior while relying on constrained nonlinear optimization to select the optimal design parameters (e.g. floor heat capacity and solar absorptance) and optimal operational conditions (e.g. use of PCM and heat recovery unit, aperture of sky windows and solar shadings). The goal is to schedule the control inputs to operate the system as much as possible as a passive energy system, with minimal active power all year round. The results show that the optimization can reduce the yearly heat demand by around 10.6%, with the solar shadings being the most significant component to be optimized. Furthermore, the optimized system is capable to supply 58% of the annual thermal demand passively – In this case, an auxiliary thermal demand of only 27 kWh/m2/year is required, which may qualify the system as a low-energy building.