Alpha radiation dosimetry using Fluorescent Nuclear Track Detectors

Journal Article (2018)
Authors

Jasper J M Kouwenberg (TU Delft - RST/Applied Radiation & Isotopes)

J.A. de Pooter (VSL Dutch Metrology Institute)

HT Wolterbeek (TU Delft - RST/Applied Radiation & Isotopes)

Antonia G. Denkova (TU Delft - RST/Applied Radiation & Isotopes)

Adrie J J bos (TU Delft - RST/Luminescence Materials)

Research Group
RST/Luminescence Materials
Copyright
© 2018 J.J.M. Kouwenberg, J. A. de Pooter, H.T. Wolterbeek, A.G. Denkova, A.J.J. bos
To reference this document use:
https://doi.org/10.1016/j.radmeas.2018.04.009
More Info
expand_more
Publication Year
2018
Language
English
Copyright
© 2018 J.J.M. Kouwenberg, J. A. de Pooter, H.T. Wolterbeek, A.G. Denkova, A.J.J. bos
Research Group
RST/Luminescence Materials
Volume number
113
Pages (from-to)
25-32
DOI:
https://doi.org/10.1016/j.radmeas.2018.04.009
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

To answer the need for better tools for alpha radiation radiobiology and microdosimetry research, a novel irradiation setup based on a honeycomb collimator, in combination with Fluorescent Nuclear Track Detectors (FNTD) for alpha radiation dosimetry and spectroscopy, was introduced. FNTDs are a novel type of small, crystalline detector that can visualize individual alpha particles and simultaneously measure their location, velocity direction and energy with good accuracy. The performance of FNTDs for alpha radiation dosimetry was evaluated for the first time and the results were compared to extrapolation chamber measurements and simulations. The surface dose rate to water of the irradiation setup for two different honeycomb collimators, measured using FNTDs, agreed with the extrapolation chamber measurements within 6%. The simulations underestimated the surface dose rate to water for the first collimator and overestimated the dose for the second collimator, indicating the sensitivity to manufacturing errors in the collimators of this irradiation setup. The dose homogeneity in the setup was measured using radiochromic film and showed variations of less than 5%, making this setup, in combination with the rich information obtained regarding the spatial, angular and energy distributions of the alpha particles, obtained using the FNTDs, ideal for microdosimetry and radiobiology experiments. The accuracy and ease-of-use of FNTDs in addition to the surface or absorbed dose and fluence of the radiation field indicate that these detectors are prime candidates for research applications in the field of alpha radionuclide therapy.

Files

FNTD_alpha_dosimetry.pdf
(pdf | 1.37 Mb)
- Embargo expired in 04-05-2020