Galvanic Brain-Coupled Communication Among Freely Floating Micro-Scale Implants

Conference Paper (2023)
Author(s)

Matteo Pola (Politecnico di Torino, TU Delft - Bio-Electronics)

Vasiliki Giagka (Fraunhofer Institute for Reliability and Microintegration IZM, TU Delft - Bio-Electronics)

Wouter A. Serdijn (TU Delft - Bio-Electronics)

Danilo Demarchi (Politecnico di Torino)

Amin Rashidi (IMEC Nederland, TU Delft - Bio-Electronics)

DOI related publication
https://doi.org/10.1109/BioCAS58349.2023.10388903 Final published version
More Info
expand_more
Publication Year
2023
Language
English
Bibliographical Note
Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.
Publisher
IEEE
ISBN (print)
979-8-3503-0027-7
ISBN (electronic)
979-8-3503-0026-0
Event
Downloads counter
259
Collections
Institutional Repository
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This paper presents a new communication method between micro-scale freely floating brain implants based on galvanic coupling (GC), called "Brain-Coupled Communication" (BCC). Since the transmission efficiency based on GC is highly dependent on the system’s geometry and the electromagnetic properties of the tissue, finite element models in COMSOL Multiphysics® are employed for characterizing the proposed method. Concurrent scaling of channel length (i.e., the distance between two implants), the inter-electrode distance (on a single implant), and electrode dimensions with a constant ratio down to 2 % of their typical values show an increase in the optimum frequency of the communication by 50 times (from 200 kHz to 10 MHz). This, in turn, yields a substantial increase in the channel bandwidth. The proposed method also shows excellent robustness against misalignment. Up to 60 ° of angular misalignment and 1 mm of lateral displacement result in a voltage-gain attenuation of less than 5 dB and 2 dB, respectively. Furthermore, a negligible shading effect between implants is observed by exploring multi-implant scenarios. Moreover, based on the conducted compliance study, no safety hazards were observed for the intended conditions. In conclusion, the proposed method exhibits a multitude of desirable qualities that position it as an excellent choice for establishing a network of freely floating brain implants.

Files

Galvanic_Brain-Coupled_Communi... (pdf)
(pdf | 3.46 Mb)
- Embargo expired in 18-07-2024
License info not available