Glare-based control strategy for Venetian blinds in a mixed-use conference space with fully glazed facades

Journal Article (2024)
Authors

Panagiota Theodoropoulou (Student TU Delft)

Eleonora Brembilla (TU Delft - Environmental & Climate Design)

HR Schipper (TU Delft - Applied Mechanics)

C. Louter (TU Delft - Applied Mechanics)

Research Group
Environmental & Climate Design
Copyright
© 2024 P. Theodoropoulou, E. Brembilla, H.R. Schipper, P.C. Louter
To reference this document use:
https://doi.org/10.1016/j.jobe.2023.108181
More Info
expand_more
Publication Year
2024
Language
English
Copyright
© 2024 P. Theodoropoulou, E. Brembilla, H.R. Schipper, P.C. Louter
Research Group
Environmental & Climate Design
Volume number
82
DOI:
https://doi.org/10.1016/j.jobe.2023.108181
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Smart buildings are equipped with automated control systems that provide a comfortable indoor environment, aiming simultaneously at energy savings. Control systems for shading devices applied in practice are mostly driven by a rule-based approach, that is usually tested under simplified conditions and hence its effectiveness in complex real-life cases is questionable. The present study develops an optimized glare-based control strategy for Venetian blinds in a real-life open-space building with totally transparent facades. The research is based on the case study of the Co-Creation Center at the TU Delft campus, which can host three different types of events: presentations, meetings and workshops. The control strategy is developed within Grasshopper, a tool for parametric and optimization problems. Radial Basis Function Optimization (RBFOpt) is utilized for the computation of the optimal blinds’ states. Within the developed control strategy, cylindrical illuminance (Ecyl) is used as a glare index, giving the opportunity to evaluate its performance. Results show that the optimized algorithm can improve the existing visual conditions in the building by an average of 80% for all activity types, although it leads to an average increase of 7% of the time when electric lighting is needed, in comparison to the current rule-based control. Finally, Ecyl displayed an overall agreement of 92.5% with DGP-based glare assessments, proving that in spaces with multiple windows and uncertain occupants’ view direction, a view-independent index can predict glare risks as well as a state-of-the-art view-dependent metric.