Receive/transmit aperture selection for 3D ultrasound imaging with a 2D matrix transducer

Journal Article (2020)
Author(s)

M. Mozaffarzadeh (TU Delft - ImPhys/Medical Imaging)

M. Soozande (Erasmus MC)

F. Fool (TU Delft - ImPhys/Medical Imaging)

Michiel Pertijs (TU Delft - Electronic Instrumentation)

H.J. Vos (Erasmus MC, TU Delft - ImPhys/Medical Imaging)

M.D. Verweij (TU Delft - ImPhys/Medical Imaging)

J. G. Bosch (Erasmus MC)

Nico Jong (TU Delft - ImPhys/Medical Imaging, Erasmus MC)

Research Group
ImPhys/Medical Imaging
Copyright
© 2020 M. Mozaffarzadeh, M. Soozande, F. Fool, M.A.P. Pertijs, H.J. Vos, M.D. Verweij, Johan G. Bosch, N. de Jong
DOI related publication
https://doi.org/10.3390/APP10155300
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 M. Mozaffarzadeh, M. Soozande, F. Fool, M.A.P. Pertijs, H.J. Vos, M.D. Verweij, Johan G. Bosch, N. de Jong
Research Group
ImPhys/Medical Imaging
Issue number
15
Volume number
10
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Recently, we realized a prototype matrix transducer consisting of 48 rows of 80 elements on top of a tiled set of Application Specific Integrated Circuits (ASICs) implementing a row-level control connecting one transmit/receive channel to an arbitrary subset of elements per row. A fully sampled array data acquisition is implemented by a column-by-column (CBC) imaging scheme (80 transmit-receive shots) which achieves 250 volumes/second (V/s) at a pulse repetition frequency of 20 kHz. However, for several clinical applications such as carotid pulse wave imaging (CPWI), a volume rate of 1000 per second is needed. This allows only 20 transmit-receive shots per 3D image. In this study, we propose a shifting aperture scheme and investigate the effects of receive/transmit aperture size and aperture shifting step in the elevation direction. The row-level circuit is used to interconnect elements of a receive aperture in the elevation (row) direction. An angular weighting method is used to suppress the grating lobes caused by the enlargement of the effective elevation pitch of the array, as a result of element interconnection in the elevation direction. The effective aperture size, level of grating lobes, and resolution/sidelobes are used to select suitable reception/transmission parameters. Based on our assessment, the proposed imaging sequence is a full transmission (all 80 elements excited at the same time), a receive aperture size of 5 and an aperture shifting step of 3. Numerical results obtained at depths of 10, 15, and 20 mm show that, compared to the fully sampled array, the 1000 V/s is achieved at the expense of, on average, about two times wider point spread function and 4 dB higher clutter level. The resulting grating lobes were at -27 dB. The proposed imaging sequence can be used for carotid pulse wave imaging to generate an informative 3D arterial stiffness map, for cardiovascular disease assessment.