CO2 stripping from ionic liquid at elevated pressures in gas-liquid membrane contactor
Stepan Bazhenov (Russian Academy of Sciences)
A. A. Malakhov (Russian Academy of Sciences)
Danila Bakhtin (Russian Academy of Sciences)
Valery Khotimskiy (Russian Academy of Sciences)
Galina Bondarenko (Russian Academy of Sciences)
Vladimir Volkov (Russian Academy of Sciences)
Mahinder Ramdin (TU Delft - Engineering Thermodynamics)
Thijs J.H. Vlugt (TU Delft - Engineering Thermodynamics)
Alexey Volkov (Russian Academy of Sciences)
More Info
expand_more
Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.
Abstract
In this study, the gas-liquid membrane contactor was considered for regeneration of the room-temperature ionic liquids (RTIL) that can be used as physical solvents for carbon dioxide capture process at elevated pressures. Poly[1-(trimethylsilyl)-1-propyne] (PTMSP) was selected as a membrane material due to its high mass transport characteristics and good mechanical properties. Nine different RTILs, such as [Emim][DCA], [Emim][BF4], [Emim][DEP], [Bmim][BF4], [Bmim][Tf2N], [Hmim][TCB], [P66614][DCA], [P66614][Br] and [P66614][Phos], were used to evaluate the solvent-membrane compatibility. The long-term sorption tests (40+ days) revealed that the solvent-membrane interaction is mainly determined by the liquid surface tension regardless of viscosity and molecular size of RTILs. For instance, [Emim][BF4] and [Emim][DCA], having the surface tension of 60.3 and 54.0 mN/m, demonstrated a very low affinity to the bulk material of PTMSP (sorption as low as 0.02 g/g; no swelling); while for the next ionic liquid [Bmim][BF4] with surface tension of 44.4 mN/m, the sorption and swelling of PTMSP was 0.79 g/g and 21%, respectively. The long-term RTIL permeation test (Δp = 40 bar, T = 50°С t > 400 h) confirmed that there is no hydrodynamic flow through PTMSP for [Emim][DCA] and [Emim][BF4]. The concept of CO2 stripping from RTIL with the membrane contactor by the pressure (Δp = 10 bar) and temperature (ΔT = 20 °С) swing was proved by using dense PTMSP membrane and [Emim][BF4]. The overall mass transfer coefficient value was equal to (1.6 − 3.8) × 10−3 cm/s with respect to liquid flow rate. By using the resistance-in-series model, it was shown that the membrane resistance contribution to the gas transfer was estimated to be approximately 8%.