Improvement of the Frequency Response Indicators by Optimal UFLS Scheme Settings

Conference Paper (2020)
Author(s)

Martha N. Acosta (Autonomous University of Nuevo León)

Manuel A. Andrade (Autonomous University of Nuevo León)

Ernesto Vázquez (Autonomous University of Nuevo León)

Choidorj Adiyabazar (National Dispatching Center Co. Ltd )

F. Gonzalez-Longatt (University of South-Eastern Norway)

José L. Rueda (TU Delft - Intelligent Electrical Power Grids)

P. Palensky (TU Delft - Intelligent Electrical Power Grids)

Research Group
Intelligent Electrical Power Grids
Copyright
© 2020 Martha N. Acosta, Manuel A. Andrade, Ernesto Vázquez, Choidorj Adiyabazar, F. Gonzalez-Longatt, José L. Rueda, P. Palensky
DOI related publication
https://doi.org/10.1109/ISIE45063.2020.9152466
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 Martha N. Acosta, Manuel A. Andrade, Ernesto Vázquez, Choidorj Adiyabazar, F. Gonzalez-Longatt, José L. Rueda, P. Palensky
Research Group
Intelligent Electrical Power Grids
Bibliographical Note
"Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public." @en
Pages (from-to)
1250-1255
ISBN (print)
978-1-7281-5636-1
ISBN (electronic)
978-1-7281-5635-4
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This research investigates the positive changes in the system frequency response indicators caused by the implementation of a set of optimal settings of an under-frequency load shedding (UFLS) scheme. The optimal under-frequency load shedding (UFLS) scheme is optimised by minimising the total amount of load shedding and taking into account the recovery process of the system frequency into its operational values after several losses of generation and satisfies the requirements of the under-frequency load shedding standard (PRC-006-SERC-02). The idea of implementing the optimal UFLS scheme is to identify how changes the minimum frequency, minimum time, rate of change of frequency and steady-state frequency when the amount of load shedding change. The optimal UFLS scheme formulation starts with identifying the variables to control with the optimisation and its respective bounds. Then, the objective function is formulated in terms of the total load shedding, and finally, the restrictions and requirements of the systems are written as inequality constraints. The optimal UFLS is evaluated in the IEEE 39-bus system. The simulations results demonstrate the suitability of the optimal UFLS to improve the frequency response indicators.