Searched for: +
(1 - 20 of 78)

Pages

document
Simoes dos Santos, D. (author), Ossenkoppele, B.W. (author), Hopf, Y.M. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Objective: Described here is the development of an ultrasound matrix transducer prototype for high-frame-rate 3-D intra-cardiac echocardiography. Methods: The matrix array consists of 16 × 18 lead zirconate titanate elements with a pitch of 160 µm × 160 µm built on top of an application-specific integrated circuit that generates transmission...
journal article 2024
document
Simoes dos Santos, D. (author), Baldini, L.B. (author), Vos, H.J. (author), Verweij, M.D. (author), de Jong, N. (author), van Neer, P.L.M.J. (author)
The accurate determination of the transfer function of ultrasound transducers is important for their design and operational performance. However, conventional methods for quantifying the transfer function, such as hydrophone measurements, radiation force balance, and pulse-echo measurements, are costly and complex due to specialized equipment...
journal article 2024
document
Hopf, Y.M. (author), Simoes dos Santos, D. (author), Ossenkoppele, Boudewine W. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This article presents an application-specific integrated circuit (ASIC) for catheter-based 3-D ultrasound imaging probes. The pitch-matched design implements a comprehensive architecture with high-voltage (HV) transmitters, analog front ends, hybrid beamforming analog-To-digital converters (ADCs), and data transmission to the imaging system....
journal article 2024
document
Wei, Luxi (author), Wahyulaksana, G. (author), Boni, Enrico (author), Noothout, E.C. (author), Tortoli, Piero (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Vos, H.J. (author)
Volumetric echocardiography can potentially give a more complete picture of cardiac dynamics than its two-dimensional (2D) counterpart. Current clinical volumetric imaging probes have relatively low frame rates, and often require ECG gating to stitch together an entire volume. This makes measuring fast dynamics of the heart as well as imaging...
conference paper 2023
document
Guo, P. (author), Fool, F. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a low-power and small-area transceiver application-specific integrated circuit (ASIC) for 3-D trans-fontanelle ultrasonography. A novel micro-beamforming receiver architecture that employs current-mode summation and boxcar integration is used to realize delay-and-sum on an N -element sub-array using N× fewer capacitive...
journal article 2023
document
Zangabad, Reza Pakdaman (author), Li, H. (author), Kouijzer, Joop J.P. (author), Langeveld, Simone A.G. (author), Beekers, Ines (author), Verweij, M.A. (author), de Jong, N. (author), Kooiman, Klazina (author)
Understanding and controlling the ultrasound contrast agent (UCA)'s response to an applied ultrasound pressure field are crucial when investigating ultrasound imaging sequences and therapeutic applications. The magnitude and frequency of the applied ultrasonic pressure waves affect the oscillatory response of the UCA. Therefore, it is...
journal article 2023
document
Luijten, Ben (author), Ossenkoppele, B.W. (author), de Jong, N. (author), Verweij, M.D. (author), Eldar, Yonina C. (author), Mischi, Massimo (author), van Sloun, Ruud J.G. (author)
Ultrasound imaging is an attractive imaging modality due to its low-cost and real-time feedback, although it often falls short in image quality compared to MRI and CT imaging. Conventional ultrasound image reconstruction, such as Delay-and-Sum beamforming, is derived from maximum-likelihood estimation. As such, no prior information is exploited...
conference paper 2023
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, J. G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This paper presents a pitch-matched transceiver ASIC integrated with a 2-D transducer array for a wearable ultrasound device for transfontanelle ultrasonography. The ASIC combines 8-fold multiplexing, 4-channel micro-beamforming (μ BF) and sub-array-level digitization to achieve a 128-fold channel-count reduction. The μ BF is based on passive...
conference paper 2023
document
Wei, Luxi (author), Wahyulaksana, G. (author), Boni, Enrico (author), Noothout, E.C. (author), Duncker, Dirk J. (author), Tortoli, Piero (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Vos, H.J. (author)
Objective: The aim of this study was to assess the feasibility and imaging options of contrast-enhanced volumetric ultrasound kidney vasculature imaging in a porcine model using a prototype sparse spiral array. Methods: Transcutaneous freehand in vivo imaging of two healthy porcine kidneys was performed according to three protocols with...
journal article 2023
document
Ossenkoppele, B.W. (author), Luijten, Ben (author), Bera, Deep (author), de Jong, N. (author), Verweij, M.A. (author), van Sloun, Ruud J.G. (author)
There is an increased desire for miniature ultrasound probes with small apertures to provide volumetric images at high frame rates for in-body applications. Satisfying these increased requirements makes simultaneous achievement of a good lateral resolution a challenge. As micro-beamforming is often employed to reduce data rate and cable count...
journal article 2023
document
Li, H. (author), Li, X. (author), Collado Lara, G. (author), Lattwein, K.R. (author), Mastik, Frits (author), Beurskens, Robert (author), van der Steen, A.F.W. (author), Verweij, M.A. (author), de Jong, N. (author), Kooiman, Klazina (author)
Ultrasound contrast-mediated medical imaging and therapy both rely on the dynamics of micron- and nanometer-sized ultrasound cavitation nuclei, such as phospholipid-coated microbubbles and phase-change droplets. Ultrasound cavitation nuclei respond non-linearly to ultrasound on a nanosecond time scale that necessitates the use of ultra-high...
journal article 2023
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe...
journal article 2022
document
Mozaffarzadeh, M. (author), Verweij, M.D. (author), de Jong, N. (author), Renaud, G.G.J. (author)
While transcranial ultrasound imaging is a promising diagnostic modality, it is still hindered due to phase aberration and multiple scattering caused by the skull. In this paper, we compare near-field phase-screen modeling (PS) to a geometry-based phase aberration correction technique (GB) when an ultrafast imaging sequence (five plane waves...
journal article 2022
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, C. (author), Vos, H.J. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This work describes an ASIC design for high-frame-rate 3D intracardiac echocardiography probes. The chip is the first to combine element-level high-voltage pulsers and time-gain-compensation analog frontends as well as subarray beamformers and in-probe digitization in a pitch-matched fashion. The integration challenge is met by a shared hybrid...
poster 2022
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this letter, a compact high-voltage (HV) transmit circuit for dense 2-D transducer arrays used in 3-D ultrasonic imaging systems is presented. Stringent area requirements are addressed by a unipolar pulser with embedded transmit/receive switch. Combined with a capacitive HV level shifter, it forms the ultrasonic HV...
journal article 2022
document
Beekers, Inés (author), Langeveld, Simone A.G. (author), Meijlink, Bram (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Kooiman, Klazina (author)
Ultrasound insonification of microbubbles can locally enhance drug delivery by increasing the cell membrane permeability. To aid development of a safe and effective therapeutic microbubble, more insight into the microbubble-cell interaction is needed. In this in vitro study we aimed to investigate the initial 3D morphology of the endothelial...
journal article 2022
document
Mozaffarzadeh, M. (author), Verschuur, D.J. (author), Verweij, M.D. (author), de Jong, N. (author), Renaud, G.G.J. (author)
In a recent study, we proposed a technique to correct aberration caused by the skull and reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. Given a sound speed map, the arrival times were calculated using a fast marching technique (FMT), which solves the Eikonal equation and, therefore...
journal article 2022
document
Deurvorst, F.R. (author), Collado Lara, G. (author), Matalliotakis, A. (author), Vos, H.J. (author), de Jong, N. (author), Daeichin, V. (author), Verweij, M.D. (author)
An in vivo range verification technology for proton beam cancer therapy, preferably in real-time and with submillimeter resolution, is desired to reduce the present uncertainty in dose localization. Acoustical imaging technologies exploiting possible local interactions between protons and microbubbles or nanodroplets might be an interesting...
journal article 2022
document
Ossenkoppele, B.W. (author), Wei, Luxi (author), Luijten, Ben (author), Vos, H.J. (author), de Jong, N. (author), Van Sloun, Ruud J.G. (author), Verweij, M.D. (author)
3-D contrast enhanced ultrasound enables better visualization of inherently 3-D vascular geometries compared to an intersecting plane. Additionally, it would allow the application of motion correction techniques for all directions. Both contrast detection and motion correction work better on high-frame rate data. However high-frame rate 3-D...
conference paper 2022
document
Guo, P. (author), Fool, F. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
The integration of 2D ultrasonic transducer arrays and pitch-matched ASICs has enabled the realization of various 3D ultrasound imaging devices in recent years [1]-[3]. As applications such as 3D intravascular ultrasonography, intra-cardiac echocardiography, and trans-fontanelle ultrasonography call for miniaturization and improved spatial...
conference paper 2022
Searched for: +
(1 - 20 of 78)

Pages