Searched for: +
(1 - 3 of 3)
document
Archeewa, E. (author)
Pile load tests are commonly used by engineers to determine its bearing capacity. At present, there are three methods of pile load tests: the static, the dynamic and the quasi-static test. The static pile load test is done by applying an axial load on the pile with a long duration. The dynamic and quasi-static tests are done with an impact load...
report 2005
document
Dijkstra, J. (author)
When in-situ tests are performed to determine the ultimate capacity of a pile after the installation, quite a lot of types of tests are available. The following tests are generally used, in order from most used method to least used method: the static testing method, dynamic testing methods, pseudostatic and statnamic testing methods. During a...
report 2004
document
Huy, N.Q. (author), Van Tol, A.F. (author), Hölscher, P. (author)
In order to improve the interpretation of the quasi-static (e.g. Statnamic) pile load tests, a research project has been started to investigate effects of the loading rate on the bearing capacity of a pile in sand. A series of laboratory tests has been carried out. The testing program consists of a series of triaxial tests for sand and a series...
report 2006