Searched for: collection%253Air
(1 - 20 of 41)

Pages

document
Visser, P.N.A.M. (author)
A method has been developed and tested for estimating calibration parameters for the six accelerometers on board the Gravity field and steady-state Ocean Circulation Explorer (GOCE) from star tracker observations. These six accelerometers are part of the gradiometer, which is the prime instrument on board GOCE. It will be shown that by taking...
journal article 2008
document
Visser, P.N.A.M. (author)
A method has been implemented and tested for estimating bias and scale factor parameters for all six individual accelerometers that will fly on-board of GOCE and together form the so-called gradiometer. The method is based on inclusion of the individual accelerometer observations in precise orbit determinations, opposed to the baseline method...
journal article 2008
document
Bouman, J. (author), Rispens, S. (author), Gruber, T. (author), Koop, R. (author), Schrama, E. (author), Visser, P. (author), Tscherning, C.C. (author), Veicherts, M. (author)
One of the products derived from the gravity field and steady-state ocean circulation explorer (GOCE) observations are the gravity gradients. These gravity gradients are provided in the gradiometer reference frame (GRF) and are calibrated in-flight using satellite shaking and star sensor data. To use these gravity gradients for application in...
journal article 2008
document
van der Kruk, E. (author), Den Braver (student), O. (author), Schwab, A.L. (author), van der Helm, F.C.T. (author), Veeger, H.E.J. (author)
In the current project, we aim to provide speed skaters with real-time feedback on how to improve their skating performance within an individual stroke. The elite skaters and their coaches wish for a system that determines the mechanical power per stroke. The push-off force of the skater is a crucial variable in this power determination. In...
journal article 2016
document
van Daal-Rombouts, P.M.M. (author), Sun, Siao (author), Langeveld, J.G. (author), Bertrand-Krajewski, J.-L. (author), Clemens, F.H.L.R. (author)
Optimisation or real time control (RTC) studies in wastewater systems increasingly require rapid simulations of sewer systems in extensive catchments. To reduce the simulation time calibrated simplified models are applied, with the performance generally based on the goodness of fit of the calibration. In this research the performance of three...
journal article 2016
document
Galatro, L. (author), Spirito, M. (author)
In this paper, we propose a method based on 3-D electromagnetic simulations, for the characteristic impedance extraction of transmission lines employed in TRL calibration, focusing on lines integrated in silicon technologies. The accuracy achieved with TRL calibrations using the proposed characteristic impedance extraction is benchmarked...
journal article 2017
document
Colson, Abigail (author), Cooke, R.M. (author)
We update the 2008 TU Delft structured expert judgment database with data from 33 professionally contracted Classical Model studies conducted between 2006 and March 2015 to evaluate its performance relative to other expert aggregation models. We briefly review alternative mathematical aggregation schemes, including harmonic weighting, before...
journal article 2017
document
Visser, P.N.A.M. (author)
A method for validating the calibration parameters of the six accelerometers on board the Gravity field and steady-state Ocean Circulation Explorer (GOCE) from star tracker observations that was originally tested by an end-to-end simulation, has been updated and applied to real data from GOCE. It is shown that the method provides estimates of...
journal article 2017
document
Pourmousavian, Naser (author), Kuo, Feng Wei (author), Siriburanon, Teerachot (author), Babaie, M. (author), Staszewski, R.B. (author)
This paper proposes an ultra-low-voltage (ULV) fractional-N all-digital PLL (ADPLL) powered from a single 0.5-V supply. While its digitally controlled oscillator (DCO) runs directly at 0.5 V, an internal switched-capacitor dc-dc converter ``doubles'' the supply voltage to all the digital circuitry and particularly regulates the time-to...
journal article 2018
document
Pan, S. (author), Luo, Yanquan (author), Heidary Shalmany, S. (author), Makinwa, K.A.A. (author)
This paper describes a high-resolution energy-efficient CMOS temperature sensor, intended for the temperature compensation of MEMS/quartz frequency references. The sensor is based on silicided poly-silicon thermistors, which are embedded in a Wien-bridge RC filter. When driven at a fixed frequency, the filter exhibits a temperature-dependent...
journal article 2018
document
Chen, Peng (author), Huang, Xiongchuan (author), Chen, Y. (author), Wu, Lianbo (author), Staszewski, R.B. (author)
To characterize an on-chip programmable delay in a low-cost and high-resolution manner, a built-in self-test based on a first-order ΔΣ time-to-digital converter with self-calibration is proposed and implemented in TSMC 28-nm CMOS. The system is self-contained, and only one digital clock is needed for the measurements. A...
journal article 2018
document
Akter, S. (author), Sehgal, R.K. (author), van der Goes, Frank (author), Makinwa, K.A.A. (author), Bult, K. (author)
This paper presents a closed-loop class-AB residue amplifier for pipelined analog-to-digital converters (ADCs). It consists of a push-pull structure with a ``split-capacitor'' biasing circuit that enhances its power efficiency. The amplifier is inherently quite linear, and so incomplete settling can be used to save power while still...
journal article 2018
document
Shu, Y. (author), Daamen, W. (author), Ligteringen, H. (author), Wang, M. (author), Hoogendoorn, S.P. (author)
The Vessel Maneuvering Prediction (VMP) model, which was developed in a previous work with the aim of predicting the interaction between vessels in ports and waterways, is optimized in this paper by considering the relative position and vessel size (length and beam). The calibration is carried out using AIS data of overtaking vessels in the...
journal article 2018
document
Vonach, Tanja (author), Kleidorfer, Manfred (author), Rauch, Wolfgang (author), Tscheikner-Gratl, F. (author)
The calibration of models for urban drainage systems has become more and more important as especially the usage of detailed models has increased considerably over the last years as the basis for planning and design. Still the effects originating from the choice of data used for model calibration are little known and advice on planning...
journal article 2019
document
Hanea, A.M. (author), Nane, G.F. (author)
Expert judgement is routinely required to inform critically important decisions. While expert judgement can be remarkably useful when data are absent, it can be easily influenced by contextual biases which can lead to poor judgements and subsequently poor decisions. Structured elicitation protocols aim to: (1) guard against biases and provide...
journal article 2019
document
Chu, L. (author), Bus, M. (author), Korobko, A.V. (author), Besseling, N.A.M. (author)
We calibrate the lateral mode AFM (LFM) by determining the position-sensitive photodetector (PSPD) signal dependency on the lateral tip displacement, which is analogous to the constant-compliance region in normal-force calibration. By stick-slip on stiff, amorphous surfaces (silica or glass), the lateral tip displacement is determined...
journal article 2019
document
Xie, S. (author), Abarca Prouza, A.N. (author), Theuwissen, A.J.P.A.M. (author)
This brief proposes employing each of the classical 4 transistor (4T) pinned photodiode (PPD) CMOS image sensor (CIS) pixels, for both imaging and temperature measurement, intended for compensating the CISs' dark current, and dark signal non-uniformity (DSNU). The proposed temperature sensors rely on the thermal behavior of MOSFETs working in...
journal article 2020
document
Yousefzadeh, B. (author), Makinwa, K.A.A. (author)
This article presents a BJT-based temperature-to-digital-converter (TDC) that achieves ±0.25 °C 3 sigma -inaccuracy from -40 °C to +180 °C after a heater-assisted voltage calibration (HA-VCAL). Its switched-capacitor (SC) ADC employs two sampling capacitors and, thus, the minimum number of critical sampling switches, which minimizes the...
journal article 2020
document
Baselmans, J.J.A. (author), Bosma, S. (author), Ikarashi, S. (author), Klapwijk, T.M. (author), Llombart, Nuria (author), Pascual Laguna, A. (author), Thoen, David (author), de Visser, P.J. (author), Yurduseven, O. (author), Endo, A. (author)
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter bank and microwave kinetic inductance detector (MKID) to investigate dusty starburst galaxies in the distant universe at millimeter and submillimeter wavelengths. An on-site experiment of...
journal article 2020
document
des Tombe, B.F. (author), Schilperoort, B. (author), Bakker, M. (author)
Distributed temperature sensing (DTS) systems can be used to estimate the temperature along optic fibers of several kilometers at a sub-meter interval. DTS systems function by shooting laser pulses through a fiber and measuring its backscatter intensity at two distinct wavelengths in the Raman spectrum. The scattering-loss coefficients for...
journal article 2020
Searched for: collection%253Air
(1 - 20 of 41)

Pages