Wahyulaksana, G. (author), Wei, Luxi (author), Voorneveld, J.D. (author), Hekkert, Maaike Te Lintel (author), Strachinaru, Mihai (author), Duncker, Dirk J. (author), de Jong, N. (author), van der Steen, A.F.W. (author), Vos, H.J. (author)
Assessing the coronary circulation with contrast-enhanced echocardiography has high clinical relevance. However, it is not being routinely performed in clinical practice because the current clinical tools generally cannot provide adequate image quality. The contrast agent's visibility in the myocardium is generally poor, impaired by motion...
journal article 2023
document
Wei, Luxi (author), Wahyulaksana, G. (author), Boni, Enrico (author), Noothout, E.C. (author), Duncker, Dirk J. (author), Tortoli, Piero (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Vos, H.J. (author)
Objective: The aim of this study was to assess the feasibility and imaging options of contrast-enhanced volumetric ultrasound kidney vasculature imaging in a porcine model using a prototype sparse spiral array. Methods: Transcutaneous freehand in vivo imaging of two healthy porcine kidneys was performed according to three protocols with...
journal article 2023
document
Caenen, Annette (author), Keijzer, Lana (author), Bézy, Stéphanie (author), Duchenne, Jürgen (author), Orlowska, Marta (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, Johan G. (author), Voigt, Jens Uwe (author), D’hooge, Jan (author), Vos, H.J. (author)
Ultrasound-based shear wave elastography is a promising technique to non-invasively assess the dynamic stiffness variations of the heart. The technique is based on tracking the propagation of acoustically induced shear waves in the myocardium of which the propagation speed is linked to tissue stiffness. This measurement is repeated multiple...
journal article 2023
document
Wei, Luxi (author), Wahyulaksana, G. (author), Boni, Enrico (author), Noothout, E.C. (author), Tortoli, Piero (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Vos, H.J. (author)
Volumetric echocardiography can potentially give a more complete picture of cardiac dynamics than its two-dimensional (2D) counterpart. Current clinical volumetric imaging probes have relatively low frame rates, and often require ECG gating to stitch together an entire volume. This makes measuring fast dynamics of the heart as well as imaging...
conference paper 2023
document
Wei, Luxi (author), Boni, Enrico (author), Ramalli, Alessandro (author), Fool, F. (author), Noothout, E.C. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Tortoli, Piero (author), de Jong, N. (author), Vos, H.J. (author)
Two-dimensional (2-D) arrays offer volumetric imaging capabilities without the need for probe translation or rotation. A sparse array with elements seeded in a tapering spiral pattern enables one-to-one connection to an ultrasound machine, thus allowing flexible transmission and reception strategies. To test the concept of sparse spiral array...
journal article 2022
document
Wahyulaksana, G. (author), Wei, Luxi (author), Schoormans, Jasper (author), Voorneveld, J.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Suppressing tissue clutter is an essential step in blood flow estimation and visualization, even when using ultrasound contrast agents. Blind source separation (BSS)-based clutter filter for high-framerate ultrasound imaging has been reported to perform better in tissue clutter suppression than the conventional frequency-based wall filter and...
journal article 2022
document
Voorneveld, J.D. (author), Keijzer, L.B.H. (author), Strachinaru, Mihai (author), Bowen, Daniel J. (author), Mutluer, Ferit O. (author), van der Steen, A.F.W. (author), Ten Cate, Folkert (author), de Jong, N. (author), Vos, H.J. (author), Van den Bosch, Annemien E. (author), Bosch, Johan G. (author)
High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output to use for HFR echoPIV (PRF = 4900 Hz) in the left ventricle (LV) of patients. Three infusion...
journal article 2021
document
Wei, Luxi (author), Wahyulaksana, G. (author), Meijlink, Bram (author), Ramalli, Alessandro (author), Noothout, E.C. (author), Verweij, M.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter...
journal article 2021
document
Keijzer, Lana B.H. (author), Caenen, A.F.M. (author), Voorneveld, J.D. (author), Strachinaru, Mihai (author), Bowen, Daniel J. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, Johan G. (author), Vos, H.J. (author)
Natural and active shear wave elastography (SWE) are potential ultrasound-based techniques to non-invasively assess myocardial stiffness, which could improve current diagnosis of heart failure. This study aims to bridge the knowledge gap between both techniques and discuss their respective impacts on cardiac stiffness evaluation. We recorded...
journal article 2020
document
Voorneveld, J.D. (author), Saaid, H. (author), Schinkel, C.V. (author), Radeljic, Nikola (author), Lippe, Boris (author), Gijsen, F.J.H. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Claessens, Tom (author), Vos, H.J. (author), Kenjeres, S. (author), Bosch, Johan G. (author)
Left ventricular (LV) blood flow is an inherently complex time-varying 3-D phenomenon, where 2-D quantification often ignores the effect of out-of-plane motion. In this study, we describe high frame rate 4-D echocardiographic particle image velocimetry (echo-PIV) using a prototype matrix transesophageal transducer and a dynamic LV phantom for...
journal article 2020
document
Keijzer, L.B.H. (author), Strachinaru, Mihai (author), Bowen, Dan J. (author), Geleijnse, Marcel L. (author), van der Steen, A.F.W. (author), Bosch, Johan G. (author), de Jong, N. (author), Vos, H.J. (author)
For the quantification of myocardial function, myocardial stiffness can potentially be measured non-invasively using shear wave elastography. Clinical diagnosis requires high precision. In 10 healthy volunteers, we studied the reproducibility of the measurement of propagation speeds of shear waves induced by aortic and mitral valve closure ...
journal article 2019
document
Bera, D. (author), Van Den Adel, Franc (author), Radeljic-Jakic, Nikola (author), Lippe, Boris (author), Soozande, M. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Kruizinga, P. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), Bosch, Johan G. (author), de Jong, N. (author)
We describe a 3-D multiline parallel beamforming scheme for real-time volumetric ultrasound imaging using a prototype matrix transesophageal echocardiography probe with diagonally diced elements and separated transmit and receive arrays. The elements in the smaller rectangular transmit array are directly wired to the ultrasound system. The...
journal article 2018
document
Bera, D. (author), Raghunathan, S.B. (author), Chen, C. (author), Chen, Z. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, J.G. (author)
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently...
journal article 2018
document
Strachinaru, Mihai (author), Bosch, Johan G. (author), van Dalen, Bas M. (author), van Gils, Lennart (author), van der Steen, A.F.W. (author), de Jong, N. (author), Geleijnse, Marcel L. (author), Vos, H.J. (author)
The propagation velocity of shear waves relates to tissue stiffness. We prove that a regular clinical cardiac ultrasound system can determine shear wave velocity with a conventional unmodified tissue Doppler imaging (TDI) application. The investigation was performed on five tissue phantoms with different stiffness using a research platform...
journal article 2017
document
Vos, H.J. (author), van Dalen, Bas M. (author), Heinonen, Ilkka (author), Bosch, Johan G. (author), Sorop, Oana (author), Duncker, Dirk J. (author), van der Steen, A.F.W. (author), de Jong, N. (author)
Cardiac muscle stiffness can potentially be estimated non-invasively with shear wave elastography. Shear waves are present on the septal wall after mitral and aortic valve closure, thus providing an opportunity to assess stiffness in early systole and early diastole. We report on the shear wave recordings of 22 minipigs with high-frame-rate...