Searched for: collection%253Air
(41 - 57 of 57)

Pages

document
Beekers, D.I. (author), Mastik, Frits (author), Beurskens, Robert (author), Tang, Phoei Ying (author), Vegter, Merel (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Kooiman, Klazina (author)
Ultrasound insonification of microbubbles can locally enhance drug delivery, but the microbubble–cell interaction remains poorly understood. Because intracellular calcium (Ca<sub>i</sub> <sup>2+</sup>) is a key cellular regulator, unraveling the Ca<sub>i</sub> <sup>2+</sup> fluctuations caused by an oscillating microbubble provides crucial...
journal article 2020
document
Mozaffarzadeh, M. (author), Minonzio, C.G. (author), de Jong, N. (author), Verweij, M.D. (author), Hemm, Simone (author), Renaud, G.G.J. (author), Daeichin, V. (author)
In the above article [1], we mentioned that the superposition of the different symmetric (S) modes in the frequencywavenumber (f-k) domain results in a high-intensity region where its slope corresponds to the longitudinal wave speed in the slab. However, we have recently understood that this highintensity region belongs to the propagation of...
journal article 2020
document
Chen, Z. (author), Soozande, M. (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This article quantitatively analyzes the impact of bit errors in digitized RF data on ultrasound image quality. The quality of B-mode images in both linear array and phased array imaging is evaluated by means of three objective image quality metrics: peak signal-to-noise ratio, structural similarity index, and contrast-to-noise ratio, when...
journal article 2020
document
Mozaffarzadeh, M. (author), Soozande, M. (author), Fool, F. (author), Pertijs, M.A.P. (author), Vos, H.J. (author), Verweij, M.D. (author), Bosch, Johan G. (author), de Jong, N. (author)
Recently, we realized a prototype matrix transducer consisting of 48 rows of 80 elements on top of a tiled set of Application Specific Integrated Circuits (ASICs) implementing a row-level control connecting one transmit/receive channel to an arbitrary subset of elements per row. A fully sampled array data acquisition is implemented by a...
journal article 2020
document
van Willigen, D.M. (author), Neer, Paul L.M.J. van (author), Massaad Mouawad, J.M. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
Transit-time ultrasonic flow meters are widely used in industry to measure fluid flow. In practice ultrasonic flow meters either show a zero-flow error or suffer from a significant random error due to a limited signal-to-noise ratio, requiring a significant amount of averaging to achieve good precision. This work presents a method that minimizes...
journal article 2020
document
Sabbadini, A. (author), Caenen, A.F.M. (author), Vos, H.J. (author), de Jong, N. (author), Verweij, M.D. (author)
Shear Wave Elastography (SWE) has been proposed to investigate cardiac health by non-invasively monitoring tissue stiffness. Previous work has shown that the plate-like geometry of the Interventricular Septum (IVS) may result in a dispersion similar to Lamb waves, complicating the link between shear wave speed and cardiac stiffness. However, the...
journal article 2019
document
Mozaffarzadeh, M. (author), Varnosfaderani, Mehdi H.H. (author), Sharma, Arunima (author), Pramanik, Manojit (author), de Jong, N. (author), Verweij, M.D. (author)
In acoustic-resolution photoacoustic microscopy (AR-PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the...
journal article 2019
document
Tan, M. (author), Chen, C. (author), Chen, Z. (author), Janjic, Jovana (author), Daeichin, V. (author), Chang, Z.Y. (author), Noothout, E.C. (author), van Soest, G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an area- and power-efficient application-specified integrated circuit (ASIC) for 3-D forward-looking intravascular ultrasound imaging. The ASIC is intended to be mounted at the tip of a catheter, and has a circular active area with a diameter of 1.5 mm on the top of which a 2-D array of piezoelectric transducer elements is...
journal article 2018
document
Kang, E. (author), Ding, Q. (author), Shabanimotlagh, M. (author), Kruizinga, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, J.W. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) designed for 3-D ultrasonic imaging of the carotid artery. This application calls for an array of thousands of ultrasonic transducer elements, far exceeding the number of channels of conventional imaging systems. The 3.6 x 6.8 mm&amp;#x00B2; ASIC...
journal article 2018
document
Bera, D. (author), Van Den Adel, Franc (author), Radeljic-Jakic, Nikola (author), Lippe, Boris (author), Soozande, M. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Kruizinga, P. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), Bosch, Johan G. (author), de Jong, N. (author)
We describe a 3-D multiline parallel beamforming scheme for real-time volumetric ultrasound imaging using a prototype matrix transesophageal echocardiography probe with diagonally diced elements and separated transmit and receive arrays. The elements in the smaller rectangular transmit array are directly wired to the ultrasound system. The...
journal article 2018
document
Daeichin, V. (author), Bera, D. (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Chen, Z. (author), Chen, C. (author), Noothout, E.C. (author), Vos, H.J. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a...
journal article 2018
document
Janjic, Jovana (author), Tan, M. (author), Daeichin, V. (author), Noothout, E.C. (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Beurskens, Robert H.S.H. (author), van Soest, G. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author), de Jong, N. (author)
Intravascular ultrasound is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking intravascular ultrasound (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2D array...
journal article 2018
document
Bera, D. (author), Raghunathan, S.B. (author), Chen, C. (author), Chen, Z. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, J.G. (author)
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (&gt;200 Hz). To address these issues, we have recently...
journal article 2018
document
Beekers, D.I. (author), van Rooij, Tom (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Kooiman, Klazina (author)
Ultrasound contrast agents consist of gas-filled coated microbubbles that oscillate upon ultrasound insonification. Their characteristic oscillatory response provides contrast enhancement for imaging and has the potential to locally enhance drug delivery. Since microbubble response depends on the local acoustic pressure, an ultrasound...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Noothout, E.C. (author), Chang, Z.Y. (author), Tan, M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a front-end application-specified integrated circuit (ASIC) integrated with a 2-D PZT matrix transducer that enables in-probe digitization with acceptable power dissipation for the next-generation endoscopic and catheter-based 3-D ultrasound imaging systems. To achieve power-efficient massively parallel analog-to-digital...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Prins, Christian (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm<sup>2</sup> ASIC, implemented...
journal article 2017
document
Leinders, S.M. (author), Westerveld, W.J. (author), Pozo, J. (author), Neer, P.L.M.J. (author), Snyder, B. (author), O'Brien, P. (author), Urbach, H.P. (author), de Jong, N. (author), Verweij, M.D. (author)
With the increasing use of ultrasonography, especially in medical imaging, novel fabrication techniques together with novel sensor designs are needed to meet the requirements for future applications like three-dimensional intercardiac and intravascular imaging. These applications require arrays of many small elements to selectively record the...
journal article 2015
Searched for: collection%253Air
(41 - 57 of 57)

Pages