Searched for: subject%3A%22Frames%22
(1 - 14 of 14)
document
Simoes dos Santos, D. (author), Ossenkoppele, B.W. (author), Hopf, Y.M. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Objective: Described here is the development of an ultrasound matrix transducer prototype for high-frame-rate 3-D intra-cardiac echocardiography. Methods: The matrix array consists of 16 × 18 lead zirconate titanate elements with a pitch of 160 µm × 160 µm built on top of an application-specific integrated circuit that generates transmission...
journal article 2024
document
Kortenbout, A.J. (author), Costerus, Sophie (author), Dudink, Jeroen (author), de Jong, N. (author), de Graaff, Jurgen C. (author), Vos, H.J. (author), Bosch, Johan G. (author)
Objective: Post-operative brain injury in neonates may result from disturbed cerebral perfusion, but accurate peri-operative monitoring is lacking. High-frame-rate (HFR) cerebral ultrasound could visualize and quantify flow in all detectable vessels using spectral Doppler; however, automated quantification in small vessels is challenging...
journal article 2024
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Soozande, Mehdi (author), Ossenkoppele, B.W. (author), Hopf, Y.M. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author), Vos, H.J. (author), Bosch, Johan G. (author)
Atrial fibrillation (AF) is the most common cardiac arrhythmia and is normally treated by RF ablation. Intracardiac echography (ICE) is widely employed during RF ablation procedures to guide the electrophysiologist in navigating the ablation catheter, although only 2-D probes are currently clinically used. A 3-D ICE catheter would not only...
journal article 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Mozaffarzadeh, M. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Kim, T. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for...
journal article 2022
document
Voorneveld, J.D. (author), Keijzer, L.B.H. (author), Strachinaru, Mihai (author), Bowen, Daniel J. (author), Mutluer, Ferit O. (author), van der Steen, A.F.W. (author), Ten Cate, Folkert (author), de Jong, N. (author), Vos, H.J. (author), Van den Bosch, Annemien E. (author), Bosch, Johan G. (author)
High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output to use for HFR echoPIV (PRF = 4900 Hz) in the left ventricle (LV) of patients. Three infusion...
journal article 2021
document
Vos, H.J. (author), Voorneveld, J.D. (author), Groot Jebbink, Erik (author), Leow, Chee Hau (author), Nie, Luzhen (author), van den Bosch, Annemien E. (author), Tang, Meng Xing (author), Freear, Steven (author), Bosch, Johan G. (author)
Cardiac function and vascular function are closely related to the flow of blood within. The flow velocities in these larger cavities easily reach 1 m/s, and generally complex spatiotemporal flow patterns are involved, especially in a non-physiologic state. Visualization of such flow patterns using ultrasound can be greatly enhanced by...
review 2020
document
Mozaffarzadeh, M. (author), Soozande, M. (author), Fool, F. (author), Pertijs, M.A.P. (author), Vos, H.J. (author), Verweij, M.D. (author), Bosch, Johan G. (author), de Jong, N. (author)
Recently, we realized a prototype matrix transducer consisting of 48 rows of 80 elements on top of a tiled set of Application Specific Integrated Circuits (ASICs) implementing a row-level control connecting one transmit/receive channel to an arbitrary subset of elements per row. A fully sampled array data acquisition is implemented by a...
journal article 2020
document
Voorneveld, J.D. (author), Saaid, H. (author), Schinkel, C.V. (author), Radeljic, Nikola (author), Lippe, Boris (author), Gijsen, F.J.H. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Claessens, Tom (author), Vos, H.J. (author), Kenjeres, S. (author), Bosch, Johan G. (author)
Left ventricular (LV) blood flow is an inherently complex time-varying 3-D phenomenon, where 2-D quantification often ignores the effect of out-of-plane motion. In this study, we describe high frame rate 4-D echocardiographic particle image velocimetry (echo-PIV) using a prototype matrix transesophageal transducer and a dynamic LV phantom for...
journal article 2020
document
Keijzer, L.B.H. (author), Strachinaru, Mihai (author), Bowen, Dan J. (author), Geleijnse, Marcel L. (author), van der Steen, A.F.W. (author), Bosch, Johan G. (author), de Jong, N. (author), Vos, H.J. (author)
For the quantification of myocardial function, myocardial stiffness can potentially be measured non-invasively using shear wave elastography. Clinical diagnosis requires high precision. In 10 healthy volunteers, we studied the reproducibility of the measurement of propagation speeds of shear waves induced by aortic and mitral valve closure ...
journal article 2019
document
Voorneveld, J.D. (author), Engelhard, S. (author), Vos, H.J. (author), Reijnen, M. (author), Gijsen, F.J.H. (author), Versluis, M. (author), Jebbink, E. Groot (author), de Jong, N. (author), Bosch, J. G. (author)
Treatment of abdominal aortic (AA) aneurysms and stenotic lesions may be improved by analyzing their associated blood flow patterns. Angle-independent blood flow patterns in the AA can be obtained by combining echo-particle image velocimetry (ePIV) with high frame rate contrast-enhanced ultrasonography. However, ePIV performance is affected...
journal article 2018
document
Strachinaru, Mihai (author), Bosch, Johan G. (author), van Dalen, Bas M. (author), van Gils, Lennart (author), van der Steen, A.F.W. (author), de Jong, N. (author), Geleijnse, Marcel L. (author), Vos, H.J. (author)
The propagation velocity of shear waves relates to tissue stiffness. We prove that a regular clinical cardiac ultrasound system can determine shear wave velocity with a conventional unmodified tissue Doppler imaging (TDI) application. The investigation was performed on five tissue phantoms with different stiffness using a research platform...
journal article 2017
document
Vos, H.J. (author), van Dalen, Bas M. (author), Heinonen, Ilkka (author), Bosch, Johan G. (author), Sorop, Oana (author), Duncker, Dirk J. (author), van der Steen, A.F.W. (author), de Jong, N. (author)
Cardiac muscle stiffness can potentially be estimated non-invasively with shear wave elastography. Shear waves are present on the septal wall after mitral and aortic valve closure, thus providing an opportunity to assess stiffness in early systole and early diastole. We report on the shear wave recordings of 22 minipigs with high-frame-rate...
journal article 2017
document
Kruizinga, P. (author), Mastik, Frits (author), van den Oord, Stijn C.H. (author), Schinkel, Arend F.L. (author), Bosch, Johannes G. (author), de Jong, N. (author), van Soest, G. (author), van der Steen, A.F.W. (author)
The carotid artery (CA) is central to cardiovascular research, because of the clinical relevance of CA plaques as culprits of stroke and the accessibility of the CA for cardiovascular screening. The viscoelastic state of this artery, essential for clinical evaluation, can be assessed by observing arterial deformation in response to the...
journal article 2014
Searched for: subject%3A%22Frames%22
(1 - 14 of 14)