Direct biomechanical manipulation of human gait stability
A systematic review
People fall more often when their gait stability is reduced. Gait stability can be directly manipulated by exerting forces or moments onto a person, ranging from simple walking sticks to complex wearable robotics. A systematic review of the literature was performed to determine: What is the level of evidence for different types of mechanical manipulations on improving gait stability? The study was registered at PROSPERO (CRD42020180631). Databases Embase, Medline All, Web of Science Core Collection, Cochrane Central Register of Controlled Trials, and Google Scholar were searched. The final search was conducted on the 1st of December, 2022. The included studies contained mechanical devices that influence gait stability for both impaired and non-impaired subjects. Studies performed with prosthetic devices, passive orthoses, and analysing post-training effects were excluded. An adapted NIH quality assessment tool was used to assess the study quality and risk of bias. Studies were grouped based on the type of device, point of application, and direction of forces and moments. For each device type, a best-evidence synthesis was performed to quantify the level of evidence based on the type of validity of the reported outcome measures and the study quality assessment score. Impaired and non-impaired study participants were considered separately. From a total of 4701 papers, 53 were included in our analysis. For impaired subjects, indicative evidence was found for medio-lateral pelvis stabilisation for improving gait stability, while limited evidence was found for hip joint assistance and canes. For non-impaired subjects, moderate evidence was found for medio-lateral pelvis stabilisation and limited evidence for body weight support. For all other device types, either indicative or insufficient evidence was found for improving gait stability. Our findings also highlight the lack of consensus on outcome measures amongst studies of devices focused on manipulating gait.
Balance recovery after tripping often requires an active adaptation of foot placement. Thus far, few attempts have been made to actively assist forward foot placement for balance recovery employing wearable devices. This study aims to explore the possibilities of active forward foot placement through two paradigms of actuation: assistive moments exerted with the reaction moments either internal or external to the human body, namely 'joint' moments and 'free' moments, respectively. Both paradigms can be applied to manipulate the motion of segments of the body (e.g., the shank or thigh), but joint actuators also exert opposing reaction moments on neighbouring body segments, altering posture and potentially inhibiting tripping recovery. We therefore hypothesised that a free moment paradigm is more effective in assisting balance recovery following tripping. The simulation software SCONE was used to simulate gait and tripping over various ground-fixed obstacles during the early swing phase. To aid forward foot placement, joint moments and free moments were applied either on the thigh to augment hip flexion or on the shank to augment knee extension. Two realizations of joint moments on the hip were simulated, with the reaction moment applied to either the pelvis or the contralateral thigh. The simulation results show that assisting hip flexion with either actuation paradigm on the thigh can result in full recovery of gait with a margin of stability and leg kinematics closely matching the unperturbed case. However, when assisting knee extension with moments on the shank, free moment effectively assist balance but joint moments with the reaction moment on the thigh do not. For joint moments assisting hip flexion, placement of the reaction moment on the contralateral thigh was more effective in achieving the desired limb dynamics than placing the reaction on the pelvis. Poor choice of placement of reaction moments may therefore have detrimental consequences for balance recovery, and removing them entirely (i.e., free moment) could be a more effective and reliable alternative. These results challenge conventional assumptions and may inform the design and development of a new generation of minimalistic wearable devices to promote balance during gait.
To affect functional relevant task-space gait parameters such as foot placement or progression angle, conventional lower-limb robotic gait rehabilitation devices require active control and synchronization of their actuators. As an alternative, we propose the use of gyroscopic actuators, portable actuators that have the ability to generate torques that are caused by and therefore intrinsically synchronized with the swing motion of the legs. Here we investigate the kinematic and kinetic effects at hip-joint level of self-induced gyroscopic torques of a shank-worn gyroscopic actuator. Preliminary results show the wearer’s swing leg motion can induce gyroscopic effects that significantly alter the kinematics of the hip-joint (p< 0.05 ) for both tested conditions in hip-joint endo/exo rotation and ab/ad-duction.
Gyroscopic actuators are appealing for wearable applications due to their ability to provide overground balance support without obstructing the legs. Multiple wearable robots using this actuation principle have been proposed, but none has yet been evaluated with humans. Here we use the GyBAR, a backpack-like prototype portable robot, to investigate the hypothesis that the balance of both healthy and chronic stroke subjects can be augmented through moments applied to the upper body. We quantified balance performance in terms of each participant’s ability to walk or remain standing on a narrow support surface oriented to challenge stability in either the frontal or the sagittal plane. By comparing candidate balance controllers, it was found that effective assistance did not require regulation to a reference posture. A rotational viscous field increased the distance healthy participants could walk along a 30mm-wide beam by a factor of 2.0, compared to when the GyBAR was worn but inactive. The same controller enabled individuals with chronic stroke to remain standing for a factor of 2.5 longer on a narrow block. Due to its wearability and versatility of control, the GyBAR could enable new therapy interventions for training and rehabilitation.