MT

Marianna A. Tryfonidou

info

Please Note

6 records found

Anatomical and biomechanical outcomes in a canine model

Journal article (2022) - Koen Willemsen, Marianna Tryfonidou, Ralph Sakkers, René M. Castelein, Amir A. Zadpoor, Peter Seevinck, Harrie Weinans, Björn Meij, Bart C.H. van der Wal
A solution for challenging hip dysplasia surgery could be a patient-specific 3D-printed shelf implant that is positioned extra-articular and restores the dysplastic acetabular rim to normal anatomical dimensions. The anatomical correction and biomechanical stability of this concept were tested in a canine model that, like humans, also suffers from hip dysplasia. Using 3D reconstructed computed tomography images the 3D shelf implant was designed to restore the radiological dysplastic hip parameters to healthy parameters. It was tested ex vivo on three dog cadavers (six hips) with hip dysplasia. Each hip was subjected to a biomechanical subluxation test, first without and then with the 3D shelf implant in place. Subsequently, an implant failure test was performed to test the primary implant fixation. At baseline, the dysplastic hips had an average Norberg angle of 88 ± 3° and acetabular coverage of 47 ± 2% and subluxated at an average of 83 ± 2° of femoral adduction. After adding the patient-specific shelf implants the dysplastic hips had an average Norberg angle of 122 ± 2° and acetabular coverage of 67 ± 3% and subluxated at an average of 117 ± 2° of femoral adduction. Implant failure after primary implant fixation occurred at an average of 1330 ± 320 Newton. This showed that the patient-specific shelf implants significantly improved the coverage and stability of dysplastic hips in a canine model with naturally occurring hip dysplasia. The 3D shelf is a promising concept for treating residual hip dysplasia with a straightforward technology-driven approach; however, the clinical safety needs to be further investigated in an experimental proof-of-concept animal study. ...
Journal article (2022) - Koen Willemsen, Marianna A. Tryfonidou, Ralph J.B. Sakkers, René M. Castelein, Martijn Beukers, Peter R. Seevinck, Harrie Weinans, Bart C.H. van der Wal, Björn P. Meij
The concept of a novel patient-specific 3D-printed shelf implant should be evaluated in a relevant large animal model with hip dysplasia. Therefore, three dogs with radiographic bilateral hip dysplasia and a positive subluxation test underwent unilateral acetabular augmentation with a 3D-printed dog-specific titanium implant. The contralateral side served as control. The implants were designed on CT-based pelvic bone segmentations and extended the dysplastic acetabular rim to increase the weight bearing surface without impairing the range of motion. Outcome was assessed by clinical observation, manual subluxation testing, radiography, CT, and gait analysis from 6 weeks preoperatively until termination at 26 weeks postoperatively. Thereafter, all hip joints underwent histopathological examination. The implantation and recovery from surgery was uneventful. Clinical subluxation tests at the intervention side became negative. Imaging showed medialization of the femoral head at the intervention side and the mean (range) CE-angle increased from 94° (84°-99°) preoperative to 119° (117°-120°) postoperative. Gait analysis parameters returned to pre-operative levels after an average follow-up of 6 weeks. Histology showed a thickened synovial capsule between the implant and the femoral head without any evidence of additional damage to the articular cartilage compared to the control side. The surgical implantation of the 3D shelf was safe and feasible. The patient-specific 3D-printed shelf implants restored the femoral head coverage and stability of dysplastic hips without complications. The presented approach holds promise to treat residual hip dysplasia justifying future veterinary clinical trials to establish clinical effectiveness in a larger cohort to prepare for translation to human clinic. ...
Journal article (2022) - Kelly Warmink, Michiel Siebelt, Philip S. Low, Frank M. Riemers, Bingbing Wang, Saskia G.M. Plomp, Marianna A. Tryfonidou, P. René van Weeren, Harrie Weinans, Nicoline M. Korthagen
OBJECTIVE: Folate receptor beta (FR-β) has been used as a clinical marker and target in multiple inflammatory diseases, including osteoarthritis (OA) and rheumatoid arthritis (RA). However, the conditions under which FR-β+ macrophages arise remain unclear and could be affected by corticosteroids. Therefore, we studied FR-β expression in vitro in macrophage subtypes and determined their response to triamcinolone acetonide (TA), a clinically often-used corticosteroid. DESIGN: Human monocyte-derived macrophages were differentiated to the known M0, M1, or M2 macrophage phenotypes. The phenotype and FR-β expression and plasticity of the macrophage subtypes were determined using flow cytometry, reverse transcription-quantitative polymerase chain reaction (RT-qPCR), and enzyme-linked immunosorbent assay (ELISA). RESULTS: FR-β expression was low in granulocyte-macrophage colony-stimulating factor (GM-CSF)-generated (M1-like) macrophages and high in macrophage colony-stimulating factor (M-CSF)-generated (M0 and M2-like) macrophages. FR-β expression remained high once the M0 or M2 macrophages were stimulated with pro-inflammatory stimuli (interferon-γ plus lipopolysaccharide) to induce M1-like macrophages. On the contrary, anti-inflammatory TA treatment skewed GM-CSF macrophage differentiation toward an M2 and FR-β+ phenotype. CONCLUSIONS: As corticosteroids skewed monocytes toward an FR-β-expressing, anti-inflammatory phenotype, even in an M1 priming GM-CSF environment, FR-β has potential as a biomarker to monitor success of treatment with corticosteroids. Without corticosteroid treatment, M-CSF alone induces high FR-β expression which remains high under pro-inflammatory conditions. This explains why pro-inflammatory FR-β+ macrophages (exposed to M-CSF) are observed in arthritis patients and correlate with disease severity. ...
Review (2021) - K. Willemsen, Michelle M. Möring, Netanja I. Harlianto, Marianna A. Tryfonidou, Bart C.H. van der Wal, H.H. Weinans, Björn P. Meij, Ralph J. B. Sakkers
Hip dysplasia (HD) is common in both humans and dogs. This interconnection is because humans and dogs descended from a common ancestor and therefore have a similar anatomy at micro- and macroscopic levels. Furthermore, dogs are the animals of choice for testing new treatments for human hip dysplasia and orthopedic surgery in general. However, little literature exists comparing HD between the two species. Therefore, the aim of this review is to describe the anatomy, etiology, pathogenesis, diagnostics, and treatment of HD in humans and dogs. HD as an orthopedic condition has many common characteristics in terms of etiology and pathogenesis and most of the differences can be explained by the evolutionary differences between dogs and humans. Likewise, the treatment of HD shows many commonalities between humans and dogs. Conservative treatment and surgical interventions such as femoral osteotomy, pelvic osteotomy and total hip arthroplasty are very similar between humans and dogs. Therefore, future integration of knowledge and experiences for HD between dogs and humans could be beneficial for both species. ...
Journal article (2019) - Imke Rudnik‐Jansen, Anna R. Tellegen, Harrie Weinans, Annelies Egas, Erik van Maarseveen, Nina Woike, George Mihov, Jens Thies, Marianna A. Tryfonidou, Laura B. Creemers, Behdad Pouran, Karin Schrijver, Björn P. Meij, Pieter J. Emans, Erin de Gendt, Rachel E. Thomas, Marja J.L. Kik, Huub M. de Visser
Background and Purpose: Corticosteroids are intra-articularly injected to relieve pain in joints with osteoarthritis (OA) or acute tissue damage such as ligament or tendon tears, despite its unverified contraindication in unstable joints. Biomaterial-based sustained delivery may prolong reduction of inflammatory pain, while avoiding harmful peak drug concentrations. Experimental Approach: The applicability of prolonged corticosteroid exposure was examined in a rat model of anterior cruciate ligament and medial meniscus transection (ACLT + pMMx) with ensuing degenerative changes. Key Results: Intra-articular injection of a bolus of the corticosteroid triamcinolone acetonide (TAA) resulted in enhanced joint instability in 50% of the joints, but neither instability-induced OA cartilage degeneration, synovitis, nor the OA-related bone phenotype was affected. However, biomaterial microsphere-based extended TAA release enhanced instability in 94% of the animals and induced dystrophic calcification and exacerbation of cartilage degeneration. In healthy joints, injection with TAA releasing microspheres had no effect at all. In vitro, TAA inhibited cell migration out of joint tissue explants, suggesting inhibited tissue healing in vivo as mechanisms for enhanced instability and subsequent cartilage degeneration. Conclusions and Implications: We conclude that short-term TAA exposure has minor effects on surgically induced unstable joints, but its extended presence is detrimental by extending instability and associated joint degeneration through compromised healing. This supports a contraindication of prolonged corticosteroid exposure in tissue damage-associated joint instability, but not of brief exposure. ...
Journal article (2019) - Maurits G.L. Olthof, Lichun Lu, Marianna A. Tryfonidou, Loek D. Loozen, Behdad Pouran, Michael J. Yaszemski, Björn P. Meij, Wouter J.A. Dhert, Jacqueline Alblas, Diederik H.R. Kempen
The main challenge in bone morphogenic protein 2 (BMP-2)-based application lies in finding strategies that prolong its effective period as it has a short biological half-life. Several BMP-2 release profiles have shown to enhance bone formation at various application sites. However, it remains to be determined which BMP-2 release profile best augments bone formation and whether this effect is location dependent. Therefore, the aim of this study was to investigate the effect of BMP-2 release from oligo[(polyethylene glycol) fumarate] bis(2-(methacryloyloxy)ethyl) phosphate (OPF-BP) composites on the osteoinductive efficacy at ectopic versus orthotopic application. By varying the BMP-2 loading method, three different OPF-BP composites were created with varied release profiles. The composites were compared with unloaded OPF-BP as negative control, and to the clinically used Infuse ® absorbable collagen sponge (ACS) as positive control. Bone formation was assessed by microcomputed tomography after 9 weeks of subcutaneous implantation and 3, 6, and 9 weeks of orthotopic implantation in rats (n = 48). Whereas a BMP-2 burst release of >49% generated significantly more bone compared with sustained release (burst release <30%) at the subcutaneous implantation site, differential release did not affect bone formation at the orthotopic site. Furthermore, all BMP-2 containing OPF-BP composites showed significantly more bone formation compared with ACS in the orthotopic implantation site. In conclusion, this study clearly shows that the osteoinductive effect of different BMP-2 release profiles is location dependent. In addition, more bone formation in OPF-BP compared with ACS at both application sites emphasizes the role of biomaterials as a scaffold to achieve proper bone tissue formation. The main challenge in bone morphogenic protein 2 (BMP-2)-based application lies in finding strategies to prolong its biologic activity as it has a short biological half-life. The present study uses a phosphate-modified oligo[(polyethylene glycol) fumarate] hydrogel that can be tuned to achieve differential release profiles of biologically active BMP-2 release. We demonstrate that this platform outperforms Infuse ® , currently used in the clinic and that the osteoinductive effect of BMP-2 is location dependent. Altogether, this study stresses the importance of evaluating efficacy of bone tissue engineering strategies at an orthotopic location rather than subcutaneously. Even more so, it emphasizes the role of biomaterials as a scaffold to achieve proper bone tissue engineering. ...