BP

B. Pouran

info

Please Note

51 records found

Abstract (2021) - P. Pavanram, Y. Li, K. Lietaert, A. Yilmaz, B. Pouran, Harrie Weinans, J.M.C. Mol, J. Zhou, A.A. Zadpoor, H. Jahr
Direct metal printed (DMP) porous iron implants possess promising mechanical and corrosion properties for various clinical application. Nevertheless, there is a requirement for better co-relation between in vitro and in vivo corrosion and biocompatibility behaviour of such biomaterials. Our present study evaluates absorption of porous iron implants under both static and dynamic conditions. Furthermore, this study characterizes their cytocompatibility using fibroblastic, osteogenic, endothelial and macrophagic cell types. In vitro degradation was performed statically and dynamically in a custom-built set-up placed under cell culture conditions (37 °C, 5% CO2 and 20% O2) for 28 days. The morphology and composition of the degradation products were analysed by scanning electron microscopy (SEM, JSM-IT100, JEOL). Iron implants before and after immersion were imaged by μCT (Quantum FX, Perkin Elmer, USA). Biocompatibility was also evaluated under static and dynamic in vitro culture conditions using L929, MG-63, HUVEC and RAW 264.7 cell lines. According to ISO 10993, cytocompatibility was evaluated directly using live/dead staining (Live and Dead Cell Assay kit, Abcam) in dual channel fluorescent optical imaging (FOI) and additionally quantified by flow cytometry. Furthermore, cytotoxicity was indirectly quantified using ISO conform extracts in proliferation assays. Strut size of DMP porous iron implants was 420 microns, with a porosity of 64% ± 0.2% as measured by micro-CT. After 28 days of physiological degradation in vitro, dynamically tested samples were covered with brownish degradation products. They revealed a 5.7- fold higher weight loss than statically tested samples, without significant changes in medium pH. Mechanical properties (E = 1600–1800 MPa) of these additively manufactured implants were still within the range of the values reported for trabecular bone, even after 28 days of biodegradation. Less than 25% cytotoxicity at 85% of the investigated time points was measured with L929 cells, while MG-63 and HUVEC cells showed 75% and 60% viability, respectively, after 24 h, with a decreasing trend with longer incubations. Cytotoxicity was analysed by two-way ANOVA and post-hoc Tukey's multiple comparisons test. Under dynamic culture conditions, live-dead staining and flow cytometric quantification showed a 2.8-fold and 5.7-fold increase in L929 and MG-63 cell survival rates, respectively, as compared to static conditions. Therefore, rationally designed and properly coated iron-based implants hold potential as a new generation of absorbable Orthopaedic implants. ...
Abstract (2021) - P. Pavanram, Y. Li, H. Jahr, J. Zhou, Yusuke Kubo, K. Lietaert, M.A. Leeflang, L.I. Fockaert, B. Pouran, J.M.C. Mol, Harrie Weinans
As compared to magnesium (Mg) and iron (Fe), solid zinc (Zn)-based absorbable implants show better degradation rates. An ideal bone substitute should provide sufficient mechanical support, but pure Zn itself is not strong enough for load-bearing medical applications. Modern processing techniques, like additive manufacturing (AM), can improve mechanical strength of Zn. To better mimic the in vivo situation in the human body, we evaluated the degradation behavior of porous Zn implants in vitro under dynamic conditions. Our study applied selective laser melting (SLM) to build topographically ordered absorbable Zn implants with superior mechanical properties. Specimens were fabricated from pure Zn powder using SLM and diamond unit cell topological design. In vitro degradation was performed under both static and dynamic conditions in a custom-built set-up under cell culture conditions (37 °C, 20% O2 and 5% CO2) for up to 28 days. Mechanical properties of the porous structures were determined according to ISO 13314: 2011 at different immersion time points. Modified ISO 10993 standards were used to evaluate biocompatibility through direct cell seeding and indirect extract-based cytotoxicity tests (MTS assay, Promega) against identically designed porous titanium (Ti-6Al-4V) specimens as reference material. Twenty-four hours after cell seeding, its efficacy was evaluated by Live-Dead staining (Abcam) and further analyzed using dual channel fluorescent optical imaging (FOI) and subsequent flow cytometric quantification. Porous Zn implants were successfully produced by means of SLM with a yield strength and Young's modulus in the range of 3.9–9.6 MPa and 265–570 MPa, respectively. Dynamic flow significantly increased the degradation rate of AM porous Zn after 28 days. Results from Zn extracts were similar to Ti-6Al-4V with >95% of cellular activity at all tested time points, confirming level 0 cytotoxicity (i.e., This study clearly shows the great potential of AM porous Zn as a bone substituting material. Moreover, we demonstrate that complex topological design permits control of mechanical properties and degradation behavior. ...
Journal article (2020) - H. M.A. Kolken, K. Lietaert, T. van der Sloten, B. Pouran, A. Meynen, G. Van Loock, H. Weinans, L. Scheys, A. A. Zadpoor
The innovative design of orthopedic implants could play an important role in the development of life-lasting implants, by improving both primary and secondary implant fixations. The concept of meta-biomaterials aims to achieve a unique combination of mechanical, mass transport, and biological properties through optimized topological design of additively manufactured (AM) porous biomaterials. In this study, we primarily focused on a specific class of meta-biomaterials, namely auxetic meta-biomaterials. Their extraordinary behavior of lateral expansion in response to axial tension could potentially improve implant-bone contact in certain orthopedic applications. In this work, a multitude of auxetic meta-biomaterials were rationally designed and printed from Ti–6Al–4V using a commercially available laser powder bed fusion process called selective laser melting. The re-entrant hexagonal honeycomb unit cell was used as a starting point, which was then parametrically tuned to obtain a variety of mechanical and morphological properties. In this two-step study, the morphology and quasi-static properties of the developed meta-biomaterials were assessed using mechanical experiments accompanied with full-field strain measurements using digital image correlation. In addition, all our designs were computationally modelled using the finite element method. Our results showed the limits of the AM processes for the production of auxetic meta-biomaterials in terms of which values of the design parameters (e.g., re-entrant angle, relative density, and aspect ratio) could be successfully manufactured. We also found that the AM process itself imparts significant influence on the morphological and mechanical properties of the resulting auxetic meta-biomaterials. This further highlights the importance of experimental studies to determine the actual mechanical properties of such metamaterials. The elastic modulus and strength of many of our designs fell within the range of those reported for both trabecular and cortical bone. Unprecedented properties like these could be used to simultaneously address the different challenges faced in the mechanical design of orthopedic implants. ...
Abstract (2020) - Y. Li, P. Pavanram, J. Zhou, M.A. Leeflang, B. Pouran, K.-U. Schröder, Harrie Weinans, T. Pufe, A.A. Zadpoor, H. Jahr
The ideal bone substituting biomaterials should possess bone-mimicking mechanical properties; have of porous interconnected structure, and adequate biodegradation behaviour to enable full recovery of bony defects. Direct metal printed porous scaffolds hold potential to satisfy all these requirements and were additively manufactured (AM) from atomized WE43 magnesium alloy powder with grain sizes between 20 and 60 μm. Their micro-structure, mechanical properties, degradation behavior and biocompatibility was then evaluated in vitro. Firstly, post-processing values nicely followed design parameters. Next, Young's moduli were similar to that of trabecular bone (i.e., E = 700–800 MPa) even after 28 days of simulated in vivo-like corrosion by in vitro immersion. Also, a relatively moderate hydrogen evolution, corresponding to a calculated 19.2% of scaffold mass loss, was in good agreement with 20.7% volume reduction as derived from reconstructed μCT images. Finally, only moderate cytotoxicity (i.e., level 0, <25%), even after extensive ISO 10993-conform testing for 72 h using MG-63 cells, was determined using WE43 extracts (2 way ANOVA, post-hoc Tukey's multiple comparisons test; α = 0.05). Cytotoxicity was further evaluated by direct live-dead staining assays, revealing a higher cell death in static culture. However, intimate cell-metal contact was observed by SEM. In summary, while pure WE43 may not yet be an ideal surface for cell adhesion, this novel AM process allows for adjusting biodegradation through topological design. Our approach holds tremendous potential to develop functional and biodegradable implants for orthopaedic applications. ...
Journal article (2019) - I. A.D. Mancini, L. Rieppo, J. Malda, B. Pouran, I. O. Afara, F. M.Serra Braganca, M. H.P. van Rijen, M. Kik, H. Weinans, J. Toyras, P. R. van Weeren
Since Galileo's days the effect of size on the anatomical characteristics of the structural elements of the body has been a subject of interest. However, the effects of scaling at tissue level have received little interest and virtually no data exist on the subject with respect to the osteochondral unit in the joint, despite this being one of the most lesion-prone and clinically relevant parts of the musculoskeletal system. Imaging techniques, including Fourier transform infrared imaging, polarized light microscopy and micro computed tomography, were combined to study the response to increasing body mass of the osteochondral unit. We analyzed the effect of scaling on structural characteristics of articular cartilage, subchondral plate and the supporting trabecular bone, across a wide range of mammals at microscopic level. We demonstrated that, while total cartilage thickness scales to body mass in a negative allometric fashion, thickness of different cartilage layers did not. Cartilage tissue layers were found to adapt to increasing loads principally in the deep zone with the superficial layers becoming relatively thinner. Subchondral plate thickness was found to have no correlation to body mass, nor did bone volume fraction. The underlying trabecular bone was found to have thicker trabeculae (r = 0.75, p < 0.001), as expected since this structure carries most loads and plays a role in force mitigation. The results of this study suggest that the osteochondral tissue structure has remained remarkably preserved across mammalian species during evolution, and that in particular, the trabecular bone carries the adaptation to the increasing body mass. ...
Journal article (2019) - M. Croes, M. C. Kruyt, J. Alblas, F.C. Öner, W. Boot, B. Pouran, M. V. Braham, S.A. Pakpahan, H. Weinans, H.C. Vogely, A.C. Fluit, W.J. Dhert
Immune cells and their soluble factors regulate skeletal cells during normal bone regeneration and pathological bone formation. Bacterial infections can trigger immune responses that activate pro-osteogenic pathways, but these are usually overshadowed by osteolysis and concerns of systemic inflammation. The aim of this study was to determine whether the transient local inflammatory reaction to non-viable bacterial immune agonists could lead to favourable new bone formation. In a series of rabbit studies, as proof-of-concept, how tibial intramedullary injection of viable or killed bacterial species affected bone remodelling and new bone formation was determined. Application of killed bacteria led to considerable new bone formation after 4 weeks, without the prolonged systemic inflammation and exaggerated bone lysis seen with active infection. The osteo-immunomodulatory effects of various species of killed bacteria and the dose response relationship were subsequently screened in ectopically-implanted ceramic scaffolds. Histomorphometry after 8 weeks showed that a relatively low dose of killed bacteria enhanced ectopic bone induction. Moreover, lipoteichoic acid - the bacterial cell-wall derived toll-like-receptor (TLR)-2 activator - was identified as an osteo-stimulatory factor. Collectively, the data indicated that bacterial stimuli could be harnessed to stimulate osteogenesis, which occurs through a synergy with osteoinductive signals. This finding holds promise for the use of non-viable bacteria, bacterial antigens, or their simplified analogues as immuno-modulatory bone regenerating tools in bone biomaterials. ...
Journal article (2019) - Yageng Li, H. Jahr, A. A. Zadpoor, P. Pavanram, Francoise Bobbert, U. Paggi, X. Y. Zhang, B. Pouran, M. A. Leeflang, H. Weinans, Jie Zhou
Additively manufactured (AM) functionally graded porous metallic biomaterials offer unique opportunities to satisfy the contradictory design requirements of an ideal bone substitute. However, no functionally graded porous structures have ever been 3D-printed from biodegradable metals, even though biodegradability is crucial both for full tissue regeneration and for the prevention of implant-associated infections in the long term. Here, we present the first ever report on AM functionally graded biodegradable porous metallic biomaterials. We made use of a diamond unit cell for the topological design of four different types of porous structures including two functionally graded structures and two reference uniform structures. Specimens were then fabricated from pure iron powder using selective laser melting (SLM), followed by experimental and computational analyses of their permeability, dynamic biodegradation behavior, mechanical properties, and cytocompatibility. It was found that the topological design with functional gradients controlled the fluid flow, mass transport properties and biodegradation behavior of the AM porous iron specimens, as up to 4-fold variations in permeability and up to 3-fold variations in biodegradation rate were observed for the different experimental groups. After 4 weeks of in vitro biodegradation, the AM porous scaffolds lost 5–16% of their weight. This falls into the desired range of biodegradation rates for bone substitution and confirms our hypothesis that topological design could indeed accelerate the biodegradation of otherwise slowly degrading metals, like iron. Even after 4 weeks of biodegradation, the mechanical properties of the specimens (i.e., E = 0.5–2.1 GPa, σy = 8–48 MPa) remained within the range of the values reported for trabecular bone. Design-dependent cell viability did not differ from gold standard controls for up to 48 h. This study clearly shows the great potential of AM functionally graded porous iron as a bone substituting material. Moreover, we demonstrate that complex topological design permits the control of mechanical properties, degradation behavior of AM porous metallic biomaterials. Statement of Significance: No functionally graded porous structures have ever been 3D-printed from biodegradable metals, even though biodegradability is crucial both for full tissue regeneration and for the prevention of implant-associated infections in the long term. Here, we present the first report on 3D-printed functionally graded biodegradable porous metallic biomaterials. Our results suggest that topological design in general, and functional gradients in particular can be used as an important tool for adjusting the biodegradation behavior of AM porous metallic biomaterials. The biodegradation rate and mass transport properties of AM porous iron can be increased while maintaining the bone-mimicking mechanical properties of these biomaterials. The observations reported here underline the importance of proper topological design in the development of AM porous biodegradable metals. ...
Journal article (2019) - R.F.M.R. Kersten, Gang Wu, Behdad Pouran, A.J. van der Veen, Harrie H. Weinans, A. de Gast, F.C. Oner, S.M. van Gaalen
Polyetheretherketone (PEEK) is commonly used as a spinal spacer for intervertebral fusion surgery. Unfortunately, PEEK is bioinert and does not effectively osseointegrate into living bone. In contrast, comparable spacers made of silicon nitride (Si3N4) possess a surface nanostructure and chemistry that encourage appositional bone healing. This observational study was designed to compare the outcomes of these two biomaterials when implanted as spacers in an adult caprine model. Lumbar interbody fusion surgeries were performed at two adjacent levels in eight adult goats using implants of PEEK and Si3N4. At six-months after surgery, the operative and adjacent spinal segments were extracted and measured for bone fusion, bone volume, bone-implant contact (BIC) and soft-tissue implant contact (SIC) ratios, and biodynamic stability. The null hypothesis was that no differences in these parameters would be apparent between the two groups. Fusion was observed in seven of eight implants in each group with greater bone formation in the Si3N4 group (52.6%) versus PEEK (27.9%; p = 0.2). There were no significant differences in BIC ratios between PEEK and Si3N4, and the biodynamic stability of the two groups was also comparable. The results suggest that Si3N4 spacers are not inferior to PEEK and they may be more effective in promoting arthrodesis. ...
Journal article (2019) - Maurits G.L. Olthof, Lichun Lu, Marianna A. Tryfonidou, Loek D. Loozen, Behdad Pouran, Michael J. Yaszemski, Björn P. Meij, Wouter J.A. Dhert, Jacqueline Alblas, Diederik H.R. Kempen
The main challenge in bone morphogenic protein 2 (BMP-2)-based application lies in finding strategies that prolong its effective period as it has a short biological half-life. Several BMP-2 release profiles have shown to enhance bone formation at various application sites. However, it remains to be determined which BMP-2 release profile best augments bone formation and whether this effect is location dependent. Therefore, the aim of this study was to investigate the effect of BMP-2 release from oligo[(polyethylene glycol) fumarate] bis(2-(methacryloyloxy)ethyl) phosphate (OPF-BP) composites on the osteoinductive efficacy at ectopic versus orthotopic application. By varying the BMP-2 loading method, three different OPF-BP composites were created with varied release profiles. The composites were compared with unloaded OPF-BP as negative control, and to the clinically used Infuse ® absorbable collagen sponge (ACS) as positive control. Bone formation was assessed by microcomputed tomography after 9 weeks of subcutaneous implantation and 3, 6, and 9 weeks of orthotopic implantation in rats (n = 48). Whereas a BMP-2 burst release of >49% generated significantly more bone compared with sustained release (burst release <30%) at the subcutaneous implantation site, differential release did not affect bone formation at the orthotopic site. Furthermore, all BMP-2 containing OPF-BP composites showed significantly more bone formation compared with ACS in the orthotopic implantation site. In conclusion, this study clearly shows that the osteoinductive effect of different BMP-2 release profiles is location dependent. In addition, more bone formation in OPF-BP compared with ACS at both application sites emphasizes the role of biomaterials as a scaffold to achieve proper bone tissue formation. The main challenge in bone morphogenic protein 2 (BMP-2)-based application lies in finding strategies to prolong its biologic activity as it has a short biological half-life. The present study uses a phosphate-modified oligo[(polyethylene glycol) fumarate] hydrogel that can be tuned to achieve differential release profiles of biologically active BMP-2 release. We demonstrate that this platform outperforms Infuse ® , currently used in the clinic and that the osteoinductive effect of BMP-2 is location dependent. Altogether, this study stresses the importance of evaluating efficacy of bone tissue engineering strategies at an orthotopic location rather than subcutaneously. Even more so, it emphasizes the role of biomaterials as a scaffold to achieve proper bone tissue engineering. ...
Journal article (2019) - Y. Li, H. Jahr, X. Y. Zhang, M. A. Leeflang, W. Li, B. Pouran, F. D. Tichelaar, H. Weinans, J. Zhou, A. A. Zadpoor
Additively manufactured (AM) biodegradable metals with topologically ordered porous structures hold unprecedented promise as potential bone substitutes. The first reports on this type of biomaterials have just recently appeared in the literature. There is, however, no information available in the literature regarding their mechanical performance under cyclic loading or the interactions between biodegradation and cyclic loading. We therefore used selective laser melting (SLM) to fabricate porous magnesium alloy (WE43) scaffolds based on diamond unit cells. The microstructure of the resulting material was examined using electron back-scattered diffraction, scanning transmission electron microscopy, and X-ray diffraction. The fatigue behaviors of the material in air and in revised simulated body fluid (r-SBF) were evaluated and compared. Biodegradation decreased the fatigue strength of the porous material from 30% to 20% of its yield strength. Moreover, cyclic loading significantly increased its biodegradation rate. The mechanistic aspects of how biodegradation and cyclic loading interacted with each other on different scales were revealed as well. On the micro-scale, cracks initiated at biodegradation pits and propagated transgranularly. In addition, dislocations became more tangled after the fatigue tests. On the macro-scale, cracks preferred initiating at the strut junctions where tensile stress concentrations were present, as revealed by the finite element analysis of the porous material under compressive loading. Most of the cracks initiated in the struts were positioned on the periphery of the specimens. Furthermore, the biodegradation pattern was found to be location-dependent with more localized biodegradation occurring in the center of the specimens. Further improvements in the biodegradation-affected fatigue performance of the AM porous Mg alloy may therefore be realized by optimizing both the topological design of the porous structure and the laser-processing parameters that determine the microstructure of the SLM porous material. ...
Journal article (2019) - João P. Garcia, Alessia Longoni, Debby Gawlitta, Antoine J.W.P. Rosenberg, Mark W. Grinstaff, Juha Töyräs, Harrie Weinans, Laura B. Creemers, Behdad Pouran
Tissue engineering and regenerative medicine are two therapeutic strategies to treat, and to potentially cure, diseases affecting cartilaginous tissues, such as osteoarthritis and cartilage defects. Insights into the processes occurring during regeneration are essential to steer and inform development of the envisaged regenerative strategy, however tools are needed for longitudinal and quantitative monitoring of cartilage matrix components. In this study, we introduce a contrast-enhanced computed tomography (CECT)-based method using a cationic iodinated contrast agent (CA4+) for longitudinal quantification of glycosaminoglycans (GAG) in cartilage-engineered constructs. CA4+ concentration and scanning protocols were first optimized to ensure no cytotoxicity and a facile procedure with minimal radiation dose. Chondrocyte and mesenchymal stem cell pellets, containing different GAG content were generated and exposed to CA4+. The CA4+ content in the pellets, as determined by micro computed tomography, was plotted against GAG content, as measured by 1,9-dimethylmethylene blue analysis, and showed a high linear correlation. The established equation was used for longitudinal measurements of GAG content over 28 days of pellet culture. Importantly, this method did not adversely affect cell viability or chondrogenesis. Additionally, the CA4+ distribution accurately matched safranin-O staining on histological sections. Hence, we show proof-of-concept for the application of CECT, utilizing a positively charged contrast agent, for longitudinal and quantitative imaging of GAG distribution in cartilage tissue-engineered constructs. Statement of Significance: Tissue engineering and regenerative medicine are promising therapeutic strategies for different joint pathologies such as cartilage defects or osteoarthritis. Currently, in vitro assessment on the quality and composition of the engineered cartilage mainly relies on destructive methods. Therefore, there is a need for the development of techniques that allow for longitudinal and quantitative imaging and monitoring of cartilage-engineered constructs. This work harnesses the electrostatic interactions between the negatively-charged glycosaminoglycans (GAGs) and a positively-charged contrast agent for longitudinal and non-destructive quantification of GAGs, providing valuable insight on GAG development and distribution in cartilage engineered constructs. Such technique can advance the development of regenerative strategies, not only by allowing continuous monitoring but also by serving as a pre-implantation screening tool. ...
Journal article (2019) - Imke Rudnik‐Jansen, Anna R. Tellegen, Harrie Weinans, Annelies Egas, Erik van Maarseveen, Nina Woike, George Mihov, Jens Thies, Marianna A. Tryfonidou, Laura B. Creemers, Behdad Pouran, Karin Schrijver, Björn P. Meij, Pieter J. Emans, Erin de Gendt, Rachel E. Thomas, Marja J.L. Kik, Huub M. de Visser
Background and Purpose: Corticosteroids are intra-articularly injected to relieve pain in joints with osteoarthritis (OA) or acute tissue damage such as ligament or tendon tears, despite its unverified contraindication in unstable joints. Biomaterial-based sustained delivery may prolong reduction of inflammatory pain, while avoiding harmful peak drug concentrations. Experimental Approach: The applicability of prolonged corticosteroid exposure was examined in a rat model of anterior cruciate ligament and medial meniscus transection (ACLT + pMMx) with ensuing degenerative changes. Key Results: Intra-articular injection of a bolus of the corticosteroid triamcinolone acetonide (TAA) resulted in enhanced joint instability in 50% of the joints, but neither instability-induced OA cartilage degeneration, synovitis, nor the OA-related bone phenotype was affected. However, biomaterial microsphere-based extended TAA release enhanced instability in 94% of the animals and induced dystrophic calcification and exacerbation of cartilage degeneration. In healthy joints, injection with TAA releasing microspheres had no effect at all. In vitro, TAA inhibited cell migration out of joint tissue explants, suggesting inhibited tissue healing in vivo as mechanisms for enhanced instability and subsequent cartilage degeneration. Conclusions and Implications: We conclude that short-term TAA exposure has minor effects on surgically induced unstable joints, but its extended presence is detrimental by extending instability and associated joint degeneration through compromised healing. This supports a contraindication of prolonged corticosteroid exposure in tissue damage-associated joint instability, but not of brief exposure. ...
Journal article (2018) - Yageng Li, H. Jahr, J. M.C. Mol, J. Zhou, A. A. Zadpoor, K. Lietaert, P. Pavanram, A. Yilmaz, L. I. Fockaert, M. A. Leeflang, B. Pouran, Y. Gonzalez-Garcia, H. Weinans
Additively manufactured (AM) topologically ordered porous metallic biomaterials with the proper biodegradation profile offer a unique combination of properties ideal for bone regeneration. These include a fully interconnected porous structure, bone-mimicking mechanical properties, and the possibility of fully regenerating bony defects. Most of such biomaterials are, however, based on magnesium and, thus, degrade too fast. Here, we present the first report on topologically ordered porous iron made by Direct Metal Printing (DMP). The topological design was based on a repetitive diamond unit cell. We conducted a comprehensive study on the in vitro biodegradation behavior (up to 28 days), electrochemical performance, time-dependent mechanical properties, and biocompatibility of the scaffolds. The mechanical properties of AM porous iron (E = 1600–1800 MPa) were still within the range of the values reported for trabecular bone after 28 days of biodegradation. Electrochemical tests showed up to ≈12 times higher rates of biodegradation for AM porous iron as compared to that of cold-rolled (CR) iron, while only 3.1% of weight loss was measured after 4 weeks of immersion tests. The biodegradation mechanisms were found to be topology-dependent and different between the periphery and central parts of the scaffolds. While direct contact between MG-63 cells and scaffolds revealed substantial and almost instant cytotoxicity in static cell culture, as compared to Ti-6Al-4V, the cytocompatibility according to ISO 10993 was reasonable in in vitro assays for up to 72 h. This study shows how DMP could be used to increase the surface area and decrease the grain sizes of topologically ordered porous metallic biomaterials made from metals that are usually considered to degrade too slowly (e.g., iron), opening up many new opportunities for the development of biodegradable metallic biomaterials. Statement of Significance: Biodegradation in general and proper biodegradation profile in particular are perhaps the most important requirements that additively manufactured (AM) topologically ordered porous metallic biomaterials should offer in order to become the ideal biomaterial for bone regeneration. Currently, most biodegradable metallic biomaterials are based on magnesium, which degrade fast with gas generation. Here, we present the first report on topologically ordered porous iron made by Direct Metal Printing (DMP). We also conducted a comprehensive study on the biodegradation behavior, electrochemical performance, biocompatibility, and the time evolution of the mechanical properties of the implants. We show that these implants possess bone-mimicking mechanical properties, accelerated degradation rate, and reasonable cytocompatibility, opening up many new opportunities for the development of iron-based biodegradable materials. ...
Journal article (2018) - Parisa Rahnamay Moshtagh, Nicoline M. Korthagen, Saskia G. Plomp, Behdad Pouran, Rene M. Castelein, Amir Zadpoor, Harrie Weinans
This study aims to investigate the earliest alterations of bone and cartilage tissues as a result of different exercise protocols in the knee joint of Wistar rats. We hypothesize that pretraining to a continuous intense running protocol would protect the animals from cartilage degeneration. Three groups of animals were used: (i) an adaptive (pretraining) running group that ran for 8 weeks with gradually increasing velocity and time of running followed by a constant running program (6 weeks of 1.12 km/hour running per day); (ii) a non‐adaptive running (constant running) group that initially rested for 8 weeks followed by 6 weeks of constant running; and (iii) a non‐running (control) group. At weeks 8, 14, and 20 bone and cartilage were analyzed. Both running groups developed mild symptoms of cartilage irregularities, such as chondrocyte hypertrophy and cell clustering in different cartilage zones, in particular after the adaptive running protocol. As a result of physical training in the adaptive running exercise a dynamic response of bone was detected at week 8, where bone growth was enhanced. Conversely, the thickness of epiphyseal trabecular and subchondral bone (at week 14) was reduced due to the constant running in the period between 8 and 14 weeks. Finally, the intermediate differences between the two running groups disappeared after both groups had a resting period (from 14 to 20 weeks). The adaptive running group showed an increase in aggrecan gene expression and reduction of MMP2 expression after the initial 8 weeks running. Thus, the running exercise models in this study showed mild bone and cartilage/chondrocyte alterations that can be considered as early‐stage osteoarthritis. The pretraining adaptive protocol before constant intense running did not protect from mild cartilage degeneration. ...
Journal article (2018) - Behdad Pouran, Vahid Arbabi, A.G. Bajpayee, J van Tiel, J. Toyras, J.S. Jurvelin, Jos Malda, Amir A. Zadpoor, Harrie Weinans
As articular cartilage is an avascular tissue, the transport of nutrients and cytokines through the tissue is essential for the health of cells, i.e. chondrocytes. Transport of specific contrast agents through cartilage has been investigated to elucidate cartilage quality. In laboratory, pre-clinical and clinical studies, imaging techniques such as magnetic imaging resonance (MRI), computed tomography (CT) and fluorescent microscopy have been widely employed to visualize and quantify solute transport in cartilage. Many parameters related to the physico-chemical properties of the solute, such as molecular weight, net charge and chemical structure, have a profound effect on the transport characteristics. Information on the interplay of the solute parameters with the imaging-dependent parameters (e.g. resolution, scan and acquisition time) could assist in selecting the most optimal imaging systems and data analysis tools in a specific experimental set up. Here, we provide a comprehensive review of various imaging systems to investigate solute transport properties in articular cartilage, by discussing their potentials and limitations. The presented information can serve as a guideline for applications in cartilage imaging and therapeutics delivery and to improve understanding of the set-up of solute transport experiments in articular cartilage. ...
Journal article (2018) - Behdad Pouran, Parisa R. Moshtagh, Vahid Arbabi, Jessica Snabel, Reinout Stoop, Jeffrey Ruberti, Jos Malda, Amir A. Zadpoor, Harrie Weinans
An important aspect in cartilage ageing is accumulation of advanced glycation end products (AGEs) after exposure to sugars. Advanced glycation results in cross-links formation between the collagen fibrils in articular cartilage, hampering their flexibility and making cartilage more brittle. In the current study, we investigate whether collagen cross-linking after exposure to sugars depends on the stretching condition of the collagen fibrils. Healthy equine cartilage specimens were exposed to l-threose sugar and placed in hypo-, iso-, or hyper-osmolal conditions that expanded or shrank the tissue and changed the 3D conformation of collagen fibrils. We applied micro-indentation tests, contrast enhanced micro-computed tomography, biochemical measurement of pentosidine cross-links, and cartilage surface color analysis to assess the effects of advanced glycation cross-linking under these different conditions. Swelling of extracellular matrix due to hypo-osmolality made cartilage less susceptible to advanced glycation, namely, the increase in effective Young's modulus was approximately 80% lower in hypo-osmolality compared to hyper-osmolality and pentosidine content per collagen was 47% lower. These results indicate that healthy levels of glycosaminoglycans not only keep cartilage stiffness at appropriate levels by swelling and pre-stressed collagen fibrils, but also protect collagen fibrils from adverse effects of advanced glycation. These findings highlight the fact that collagen fibrils and therefore cartilage can be protected from further advanced glycation ("ageing") by maintaining the joint environment at sufficiently low osmolality. Understanding of mechanochemistry of collagen fibrils provided here might evoke potential ageing prohibiting strategies against cartilage deterioration. ...

Intravascular ultrasound vs. optical coherence tomography

This experimental work focused on the sensor selection for the development of a needle-like instrument to treat small isolated cartilage defects with hydrogels. The aim was to identify the most accurate and sensitive imaging method to determine the location and size of defects compared to a gold standard (µCT). Only intravascular ultrasound imaging (IVUS) vs. optical coherent tomography (OCT) were looked at, as they fulfilled the criteria for integration in the needle design. An in-vitro study was conducted on six human cadaveric tali that were dissected and submerged in saline. To simulate the natural appearance of cartilage defects, three types of defects were created via a standardised protocol: osteochondral defects (OCD), chondral defects (CD) and cartilage surface fibrillation (CSF), all sized between 0.1 and 3 mm in diameter. The detection rate by two observers for all diameters of OCD were 80, 92 and 100% with IVUS, OCT and µCT, for CD these were 60, 83 and 97%, and for CSF 0, 29 and 24%. Both IVUS and OCT can detect the presence of OCD and CD accurately if they are larger than 2 mm in diameter, and OCT can detect fibrillated cartilage defects larger than 3 mm in diameter. A significant difference between OCT–µCT and IVUS–µCT was found for the diameter error (p = 0.004) and insertion depth error (p = 0.002), indicating that OCT gives values closer to reference µCT. The OCT imaging technique is more sensitive to various types and sizes of defects and has a smaller diameter, and is therefore preferred for the intended application. ...
Journal article (2018) - J.S. Kuperus, E.J.M. Smit, P.A. de Jong, J-J Verlaan, Behdad Pouran, R.W. van Hamersvelt, Marijn van Stralen, P.R. Seevinck, C.F. Buckens, Ronald L.A.W. Bleys, Harrie H. Weinans, F. C. Oner
Diffuse idiopathic skeletal hyperostosis (DISH) is often theorized to be an ossification of the anterior longitudinal ligament (ALL). Using computed tomography (CT) imaging and cryomacrotome sectioning, we investigated the spatial relationship between the ALL and newly formed bone in DISH to test this hypothesis. In the current study, four human cadaveric spines diagnosed with DISH using CT imaging were frozen and sectioned using a cryomacrotome. Photographs were obtained of the specimen at 125 µm intervals. Manual segmentations of the ALL on cryomacrotome photographs were projected onto the three-dimensional reconstructed CT scans. The presence and location of newly formed bone were assessed in relationship to the location of the ALL. The ALL could be identified and segmented on the photographs at all levels. The ALL was located at the midline at levels where no new bone had formed. At the locations where new bone had abundantly formed, the ALL was displaced towards to the contralateral side and not replaced by bony tissue. The displacement of the—morphologically normal appearing—ALL away from the newly formed bone implies that newly formed bone in DISH may not originate from the ALL. ...
Journal article (2018) - M. Croes, S. Bakhshandeh, C. H.E. Boel, J. Alblas, A. A. Zadpoor, H. Weinans, S. Amin Yavari, I. A.J. van Hengel, K. Lietaert, K. P.M. van Kessel, B. Pouran, B. C.H. van der Wal, H. C. Vogely, W. Van Hecke, A. C. Fluit
Implant-associated infections (IAI) are often recurrent, expensive to treat, and associated with high rates of morbidity, if not mortality. We biofunctionalized the surface of additively manufactured volume-porous titanium implants using electrophoretic deposition (EPD) as a way to eliminate the peri-operative bacterial load and prevent IAI. Chitosan-based (Ch) coatings were incorporated with different concentrations of silver (Ag) nanoparticles or vancomycin. A full-scale in vitro and in vivo study was then performed to evaluate the antibacterial, immunogenic, and osteogenic activity of the developed implants. In vitro, Ch + vancomycin or Ch + Ag coatings completely eliminated, or reduced the number of planktonic and adherent Staphylococcus aureus by up to 4 orders of magnitude, respectively. In an in vivo tibia intramedullary implant model, Ch + Ag coatings caused no adverse immune or bone response under aseptic conditions. Following Staphylococcus aureus inoculation, Ch + vancomycin coatings reduced the implant infection rate as compared to chitosan-only coatings. Ch + Ag implants did not demonstrate antibacterial effects in vivo and even aggravated infection-mediated bone remodeling including increased osteoclast formation and inflammation-induced new bone formation. As an explanation for the poor antibacterial activity of Ch + Ag implants, it was found that antibacterial Ag concentrations were cytotoxic for neutrophils, and that non-toxic Ag concentrations diminished their phagocytic activity. This study shows the potential of EPD coating to biofunctionalize porous titanium implants with different antibacterial agents. Using this method, Ag-based coatings seem inferior to antibiotic coatings, as their adverse effects on the normal immune response could cancel the direct antibacterial effects of Ag nanoparticles. Statement of Significance: Implant-associated infections (IAI) are a clinical, societal, and economical burden. Surface biofunctionalization approaches can render complex metal implants with strong local antibacterial action. The antibacterial effects of inorganic materials such as silver nanoparticles (Ag NPs) are often highlighted under very confined conditions in vitro. As a novelty, this study also reports the antibacterial, immunogenic, and osteogenic activity of Ag NP-coated additively-manufactured titanium in vivo. Importantly, it was found that the developed coatings could impair the normal function of neutrophils, the most important phagocytic cells protecting us from IAI. Not surprisingly, the Ag NP-based coatings were outperformed by an antibiotic-based coating. This emphasizes the importance of also targeting implant immune-modulatory functions in future coating strategies against IAI. ...