ST

Sören Toksvig-Larsen

info

Please Note

13 records found

Journal article (2024) - Thies J.N. van der Lelij, Lennard A. Koster, Perla J. Marang-van de Mheen, Sören Toksvig-Larsen, Rob G.H.H. Nelissen, Bart L. Kaptein
Background and purpose — Different marker-selection methods are applied to represent implant and tibial seg-ments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations (“consistent-marker method”) is used or all available markers at each follow-up (“all-marker method”). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. Methods — Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evalu-ated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. Results — Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval –0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. Conclusion — Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening. ...

A Secondary Analysis of 5 Radiostereometric Analysis Studies with 10-Year Follow-up

Journal article (2024) - Thies J.N. Van Der Lelij, Bart L. Kaptein, Roula Tsonaka, Rob G.H.H. Nelissen, Sören Toksvig-Larsen, Perla J. Marang-Van De Mheen
Background:Radiostereometric analysis (RSA) provides highly accurate data about the migration of a total knee arthroplasty (TKA) component. However, patient-reported outcome measures (PROMs) reflect the patients' perspective of their functional status, pain, and overall health after TKA. The aim of this study was to evaluate the association between tibial implant migration and change in postoperative PROMs and clinical scores, using data pooled from long-Term follow-up RSA studies.Methods:Individual implant migration data were collected from 5 randomized RSA studies, including a total of 300 patients with 6 distinct TKA implant designs (all Stryker). Tibial implant migration (maximum total point motion [MTPM]) was evaluated with RSA at 3 months, 1 year, and 2, 5, 7, and 10 years postoperatively. The Knee Society Score (KSS)-Knee and KSS-Function and Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales were collected in all studies at the same follow-up times. Linear mixed-effects models, with adjustment for TKA implant design and patient characteristics, were used to analyze the data. The 3-month follow-up visit was used as the baseline to assess the association between implant migration and PROMs across the 10-year follow-up.Results:No association between tibial implant migration and change in KSS-Knee (p = 0.384), KSS-Function (p = 0.737), KOOS-Symptoms (p = 0.398), KOOS-Pain (p = 0.699), KOOS-Activities of Daily Living (p = 0.205), KOOS-Sport and Recreation (p = 0.702), or KOOS-Quality of Life (p = 0.368) was found across the entire follow-up. Similar results were found when using the 2-year follow-up as the baseline, after which both cemented and uncemented implants are expected to have stabilized.Conclusions:Tibial baseplate migration was not associated with postoperative worsening in PROMs or clinical scores in patients who underwent TKA. These findings suggest that implant migration, as measured with RSA, measures a different parameter (i.e., implant-bone fixation) than PROMs (i.e., patient perception) and clinical scores. Therefore, to assess the performance and safety of TKA implant designs, RSA and PROMs cannot be used interchangeably during the postoperative follow-up of patients and evaluation of the fixation of knee implants.Level of Evidence:Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence. ...
Journal article (2024) - Thies J. N. van der Lelij, Perla J. Marang-van de Mheen, Bart L. Kaptein, Lennard A. Koster, Peter Ljung, Rob G. H. H. Nelissen, Sören Toksvig-Larsen
Aims The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening. Cite this article: Bone Joint J 2024;106-B(2):136–143. ...

Five-Year Results of a Randomized Controlled Trial Using Radiostereometric Analysis

Journal article (2023) - Thies J.N. van der Lelij, Perla J. Marang-van de Mheen, Bart L. Kaptein, Sören Toksvig-Larsen, Rob G.H.H. Nelissen
BACKGROUND: Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their cemented counterparts. Therefore, critical evaluation of longer-term tibial component migration is needed. We investigated migration of a cementless 3D-printed and a cemented tibial component with otherwise similar TKA design during 5 years of follow-up, particularly the progression in migration beyond 2 years postoperatively. METHODS: Seventy-two patients were randomized to a cementless 3D-printed Triathlon Tritanium (Stryker) cruciate-retaining (CR) TKA or a cemented Triathlon CR (Stryker) TKA implant. Implant migration was evaluated with RSA at baseline and postoperatively at 3 months and at 1, 2, and 5 years. The maximum total point motion (MTPM) of the tibial component was compared between the groups at 5 years, and progression in migration was assessed between 2 and 5 years. Individual implants were classified as continuously migrating if the MTPM was ≥0.1 mm/year beyond 2 years postoperatively. Clinical scores were evaluated, and a linear mixed-effects model was used to analyze repeated measurements. RESULTS: At 5 years, the mean MTPM was 0.66 mm (95% confidence interval [CI], 0.56 to 0.78 mm) for the cementless group and 0.53 mm (95% CI, 0.43 to 0.64 mm) for the cemented group (p = 0.09). Between 2 and 5 years, there was no progression in mean MTPM for the cementless group (0.02 mm; 95% CI, -0.06 to 0.10 mm) versus 0.07 mm (95% CI, 0.00 to 0.14) for the cemented group. One implant was continuously migrating in the cementless group, and 4 were continuously migrating in the cemented group. The clinical scores were comparable between the groups across the entire time of follow-up. CONCLUSIONS: No significant difference in mean migration was found at 5 years between the cementless and cemented TKA implants. Progression of tibial component migration was present beyond 2 years for the cemented implant, whereas the cementless implant remained stable after initial early migration. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence. ...

A 5-year followup of 2 randomized controlled trials using radiostereometric analysis

Journal article (2022) - Shaho Hasan, Bart L. Kaptein, Perla J. MARANG-VAN DE MHEEN, Koen T. VAN HAMERSVELD, Rob G.H.H. Nelissen, Sören Toksvig-Larsen
Background and purpose — In total knee arthroplasty (TKA), metal-backed (MBT) and all-polyethylene (APT) designs have shown comparable implant migration up to 2 years postoperatively using radiostereometric analysis (RSA). However, studies comparing mid-term migration of both designs are lacking. Furthermore, continuously migrating TKAs up to 2 years may continue to migrate or stabilize thereafter. Therefore, we compared 5-year migration of MBT and APT using either cruciate-stabilizing (CS) or posteriorstabilizing (PS) designs and specifically assessed migration profiles of continuously migrating TKAs beyond 2 years. Patients and methods — The present study includes results from 2 randomized trials comparing migration of cemented MBT with APT of either CS (CS study, n = 59) or PS (PS study, n = 56) design. 2 surgeons performed all surgeries. We used a linear mixed model for the analyses. Results — The overall migration between MBT and APT TKAs was similar for either the CS or PS design over a 5-year period. In both studies combined, 9 implants showed continuous migration in the second postoperative year, of which 1 (APT-CS) was revised for instability, 4 (2 MBT-CS, MBT-PS, APT-PS) stabilized, and 4 (2 MBT-CS, APT-CS, MBT-PS) lacked 5-year data. Interpretation — Overall migration was similar between MBT and APT TKAs up to 5 years, for both the CS and PS design. 4 initially migrating TKAs stabilized between 2-and 5-year follow-up, stressing the need for longer-term followup to determine whether second-year continuous migration correctly predicts loosening. ...
Journal article (2021) - Shaho Hasan, Bart L. Kaptein, Rob G.H.H. Nelissen, Koen T. van Hamersveld, Sören Toksvig-Larsen, Perla J. Marang-van de Mheen
BACKGROUND: Orthopaedic surgeons aim for mechanical alignment when performing total knee arthroplasty (TKA) as malalignment is associated with loosening. Loosening may be predicted by migration as measured with radiostereometric analysis (RSA), but previous RSA studies on postoperative alignment have shown contradictory results and have been limited to cemented implants and small numbers of patients. Therefore, we performed a secondary analysis of 10 previously published randomized controlled trials (RCTs) to compare migration between postoperative in-range and out-of-range cemented and uncemented TKA implants among patients with a preoperative varus or valgus knee. METHODS: All RCTs involving the use of RSA that had been conducted at 2 centers were included. Alignment was classified, with use of the hip-knee-ankle angle (HKA), as in-range (0° ± 3°) or out-of-range (<-3° or >3°). The fixation methods included cemented, uncemented-coated, and uncemented-uncoated. Migration was measured at 3, 12, and 24 months. A linear mixed model was used, with adjustment for fixation method and clustering of patients within centers. RESULTS: Of 476 TKA implants that had been out-of-range preoperatively, 290 were in-range postoperatively and 186 were out-of-range in either varus (n = 143) or valgus (n = 43) postoperatively. The mean migration at 3, 12, and 24 months was 0.73 mm (95% confidence interval [CI], 0.66 to 0.79 mm), 0.92 mm (95% CI, 0.85 to 1.00 mm), and 0.97 mm (95% CI, 0.90 to 1.05 mm), respectively, for the in-range group and 0.80 mm (95% CI, 0.72 to 0.87 mm), 0.98 (95% CI, 0.90 to 1.07 mm), and 1.04 mm (95% CI, 0.95 to 1.13 mm), respectively, for the out-of-range group (p = 0.07). The fixation method significantly influenced migration, with uncemented-uncoated implants migrating more than cemented and uncemented-coated implants (p < 0.001). CONCLUSIONS: Postoperative alignment did not influence migration of TKAs in the first 2 postoperative years in patients with preoperative varus or valgus alignment of the knee. However, the fixation method significantly influenced migration, with uncemented-uncoated implants showing the greatest migration. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. ...

A Meta-Analysis of Long-Term Follow-up Radiostereometric Analysis Data

Journal article (2021) - Koen T. van Hamersveld, Perla J. Marang-van de Mheen, Roula Tsonaka, Kjell G. Nilsson, Sören Toksvig-Larsen, Rob G.H.H. Nelissen
BACKGROUND: Radiostereometric analysis (RSA) is a highly accurate tool to detect implant migration and predict loosening following total knee arthroplasty (TKA). However, little is known about the predisposing risk factors for implant migration, nor which migration profile should be considered physiological (i.e., merely part of an implant-settling phase) and which should be considered pathological (i.e., having a high probability for implant loosening). By pooling individual participant data from long-term follow-up RSA studies, we aimed to identify predisposing risk factors for tibial component loosening. METHODS: Individual data were collected for 630 patients from 11 RSA studies. The repeated measurements were analyzed with use of a linear mixed-effects model, determining the effect of age, sex, body mass index, diagnosis, preoperative and postoperative limb alignment, and prosthesis characteristics on tibial component migration over time, taking into account the clustering of patients within studies. RESULTS: High initial migration was found to result in early mechanical loosening in 18 cases (2.9%) and septic loosening in 2 cases (0.3%), whereas stabilization of high initial migration occurred in 17 cases (2.7%). Late loosening occurred in 13 cases (2.1%). All other 580 cases (92.1%) showed early stabilization and remained stable over time. Mixed-effects model analyses showed that for cemented prostheses, sex, diagnosis, and posterior cruciate ligament type had an effect on migration, but these differences were nonsignificant when analyzing migration from 3 months onwards. Uncemented prostheses aligned in varus showed more migration than neutrally and valgus-aligned TKAs (p = 0.031), and this difference increased over time (p < 0.001). Significantly higher migration was observed following uncemented TKA without an osseointegration-promoting surface (p < 0.001). CONCLUSIONS: For cemented prostheses, increased migration during the first 3 postoperative months was observed for female patients, patients with rheumatoid arthritis, and patients who underwent a posterior-stabilized TKA. For uncemented prostheses, both postoperative varus alignment of the lower limb and the absence of an osseointegration-promoting surface significantly increased postoperative tibial component migration. LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence. ...

Two-year results of a randomized controlled trial using radiostereometric analysis

Journal article (2020) - S. Hasan, K. T.Van Hamersveld, P.J. Marang-van de Mheen, B. L. Kaptein, R. G.H.H. Nelissen, S. Toksvig-Larsen
Although bone cement is the primary mode of fixation in total knee arthroplasty (TKA), cementless fixation is gaining interest as it has the potential of achieving lasting biological fixation. By 3D printing an implant, highly porous structures can be manufactured, promoting osseointegration into the implant to prevent aseptic loosening. This study compares the migration of cementless, 3D-printed TKA to cemented TKA of a similar design up to two years of follow-up using radiostereometric analysis (RSA) known for its ability to predict aseptic loosening. Methods A total of 72 patients were randomized to either cementless 3D-printed or a cemented cruciate retaining TKA. RSA and clinical scores were evaluated at baseline and postoperatively at three, 12, and 24 months. A mixed model was used to analyze the repeated measurements. Results The mean maximum total point motion (MTPM) at three, 12, and 24 months was 0.33 mm (95% confidence interval (CI) 0.25 to 0.42), 0.42 mm (95% CI 0.33 to 0.51), and 0.47 mm (95% CI 0.38 to 0.57) respectively in the cemented group, versus 0.52 mm (95% CI 0.43 to 0.63), 0.62 mm (95% CI 0.52 to 0.73), and 0.64 mm (95% CI 0.53 to 0.75) in the cementless group (p = 0.003). However, using three months as baseline, no difference in mean migration between groups was found (p = 0.497). Three implants in the cemented group showed a > 0.2 mm increase in MTPM between one and two years of follow-up. In the cementless group, one implant was revised due to pain and progressive migration, and one patient had a liner-exchange due to a deep infection. Conclusion The cementless TKA migrated more than the cemented TKA in the first two-year period. This difference was mainly due to a higher initial migration of the cementless TKA in the first three postoperative months after which stabilization was observed in all but one malaligned and early revised TKA. Whether the biological fixation of the cementless implants will result in an increased long-term survivorship requires a longer follow-up. ...

A reanalysis with comparable mean outcomes despite distinct types of measurement error

Journal article (2019) - Koen T. van Hamersveld, Perla J. Marang–van de Mheen, Lennard A. Koster, Rob G.H.H. Nelissen, Sören Toksvig-Larsen, Bart L. Kaptein
Background and purpose — Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method, including insert micromotions in modular TKA and their effect on estimated group differences. Patients and methods — All patients had received a cemented Triathlon implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed (n = 28) tibial component. The latter group was reanalyzed with model-based RSA. Precision of each RSA method was calculated using double examinations. Bland–Altman plots were constructed to determine the limits of agreement between the 2 RSA methods. Polyethylene insert micromotion was quantified by measuring migration with respect to the metal tray. Finally, analyses of the original study were repeated with the model-based RSA results. Results — Systematic differences were found in translations between marker-based and model-based RSA as a result of different reference origins being used for migration calculations. Micromotions of the polyethylene insert within the metal tray were negligibly small. Mean migration results were comparable between marker-based and model-based RSA when using the same reference origin, even though conclusions on individual patients may differ between RSA methods due to various types of measurement error (e.g., marker occlusion and model-fit inaccuracies). Interpretation — At least for the studied TKA design, pooling mean migration data of different RSA methods appears justified. For translations, however, adjustments should be made to correct for differences in reference origin. Migration patterns of individual patients may differ as a result of distinct types of measurement error. ...

Similar 2-year results of a randomized radiostereometric analysis study

Journal article (2019) - Shaho Hasan, Perla J. Marang-Van De Mheen, Bart L. Kaptein, Rob G.H.H. Nelissen, Sören Toksvig-Larsen
Background and purpose — The all-polyethylene tibial (APT) component, introduced in the early 1970s, was surpassed by metal-backed tibial (MBT) trays as the first choice for total knee arthroplasty (TKA). With improved polyethylene, the modern APT components can reduce costs, and have shown equivalent results in survivorship and early migration of the cruciate-retaining and cruciate-stabilizing designs. This study compares the 2-year migration of a similarly designed APT-posterior stabilized (PS) and a MBT-PS TKA, using radiostereometric analysis (RSA). Patients and methods — 60 patients were randomized to receive either an APT Triathlon PS or an MBT Triathlon PS TKA (Stryker, NJ, USA). Migration measured by RSA and clinical scores were evaluated at baseline and at 3, 12, and 24 months postoperatively. Repeated measurements were analyzed with a linear mixed model and generalized estimating equations. Results — The mean maximum total point movement (MTPM) at 3, 12, and 24 months was 0.41 mm (95% CI 0.33–0.50), 0.57 mm (0.44–0.70), and 0.56 mm (0.42–0.69) respectively in the MBT group and 0.46 mm (0.36–0.57), 0.61 mm (0.49–0.73), and 0.64 mm (0.50–0.77) in the APT group. 2 MBT and 1 APT implant were considered unstable at the 2-year follow-up. The KSS Knee score and KSS Function across 3, 12, and 24 months were comparable in both groups. Interpretation — For an APT-PS designed component, MTPM measured with RSA is comparable to the MBT-PS component after 2 years of follow-up. No differences in complications or clinical outcomes were found. ...

Long-term RSA results of a randomized controlled trial and limitations of short-term results

Journal article (2018) - Koen T. Van Hamersveld, Perla J. Marang-Van De Mheen, Rob G.H.H. Nelissen, Sören Toksvig-Larsen
Background and purpose — Biological fixation of uncemented knee prostheses can be improved by applying hydroxyapatite coating around the porous surface via a solution deposition technique called Peri-Apatite (PA). The 2-year results of a randomized controlled trial, evaluating the effect of PA, revealed several components with continuous migration in the second postoperative year, particularly in the uncoated group. To evaluate whether absence of early stabilization is diagnostic of loosening, we now present long-term follow-up results. Patients and methods — 60 patients were randomized to PA-coated or uncoated (porous only) total knee arthroplasty of which 58 were evaluated with radiostereometric analysis (RSA) performed at baseline, at 3 months postoperatively and at 1, 2, 5, 7, and 10 years. A linear mixed-effects model was used to analyze the repeated measurements. Results — PA-coated components had a statistically significantly lower mean migration at 10 years of 0.94 mm (95% CI 0.72–1.2) compared with the uncoated group showing a mean migration of 1.72 mm (95% CI 1.4–2.1). Continuous migration in the second postoperative year was seen in 7 uncoated components and in 1 PA-coated component. All of these implants stabilized after 2 years except for 2 uncoated components. Interpretation — Peri-apatite enhances stabilization of uncemented components. The number of components that stabilized after 2 years emphasizes the importance of longer follow-up to determine full stabilization and risk of loosening in uncemented components with biphasic migration profiles. ...
Journal article (2018) - Koen T. Van Hamersveld, Perla J. Marang-Van De Mheen, Rob G.H.H. Nelissen, Sören Toksvig-Larsen
Background and purpose — With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analysis (RSA), a proven predictor for late aseptic loosening, have been scantily reported. The purpose of this study was to compare implant migration and clinical outcomes of all-polyethylene tibial components versus metal-backed trays of similar geometrical shape. Patients and methods — In this randomized controlled trial, 59 patients received a cemented Triathlon condylar-stabilizing implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed tibial component (n = 30). RSA measurements and clinical scores (the Knee Society Score, Forgotten Joint Score, and Knee Osteoarthritis and Injury Outcome Score) were evaluated at baseline and postoperatively at 3, 12, and 24 months. A linear mixed-effects model was used to analyze the repeated measurements. Results — A statistically significant difference in mean migration after 2 years was found in favor of the all-polyethylene group, with a mean maximum total point motion of 0.61 mm (95% CI 0.49–0.74) versus 0.81 mm (95% CI 0.68–0.96) for the cemented group (p = 0.03). However, this difference was smaller and not statistically significant after post hoc adjustment for surgeon effect. Both groups showed comparable improvements on all clinical outcome scores over time. Interpretation — The Triathlon all-polyethylene tibial component showed less migration, suggesting a lower risk of late loosening as compared with its metal-backed counterpart. However, the found surgeon effect warrants further investigation. ...

Five-year follow-up of a randomised controlled trial , using radiostereometric analysis (RSA)

Journal article (2017) - K. T. Van Hamersveld, P. J. Marang-Van De Mheen, R. Tsonaka, E. R. Valstar, S. Toksvig-Larsen
Aims The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs. Patients and Methods Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements. Results After five years of follow-up, one (cemented) component was revised due to ligament instability. Overall, uncemented PA-coated tibial components migrated significantly more (p = 0.003), with the mean maximum total point motion (MTPM) at five years being 0.62 mm (95% confidence intervals (CI) 0.49 to 0.76) for cemented tibial components and 0.97 mm (95% CI 0.81 to 1.15) for PA-coated tibial components in TKA. However, between three months and five years the cemented TKAs migrated significantly more (p = 0.02), displaying a MTPM of 0.27 mm (95% CI, 0.19 to 0.36) versus 0.13 mm (95% CI, 0.01 to 0.25) for PAcoated tibial components. One implant in each group was considered at risk for aseptic loosening due to continuous migration after five years of follow-up, albeit with different migration patterns for each group (i.e. higher initial migration but diminishing over time for the PA-coated component versus gradually increasing migration for the cemented component). Conclusion The tibial components of PA-coated TKAs showed more overall migration compared with the tibial components of cemented TKAs. However, post hoc analysis showed that this difference was caused by higher migration of PA-coated components in the first three months, after which a stable migration pattern was observed. Clinically, there was no significant difference in outcome between the groups. ...