JM

Jannis Meents

info

Please Note

3 records found

Abstract (2023) - B. de Wagenaar, Sandro Meucci, Hector Castro- Abril, Rosa Monge, Udo Kraushaar, Jannis Meents, N. Gaio, Agnes Bußmann, Richard Klemm, Massimo Mastrangeli
The Smart Multi-Well Plate (SMWP), an open technology platform for Organ-on-Chip (OoC) technology developed as part of the Moore4Medical (M4M) consortium, aims to showcase the advantages of standardization in design, manufacturing and assembly for OoC [1]. In previously presented work [2], we showed integration and characterization of piezoelectric micropumps for in-line perfusion of OoC devices. Here we present the integration and preliminary biological evaluation of three OoC devices in a SMWP prototype. This prototype, a downscaled version of the full SMWP, is constructed using stacked, predefined layers. The reservoirs of a 96-well plate are fluidically connected to integrated OoC devices and micropumps through a fluidic circuit board (FCB). A printed circuit board, assembled below the FCB, enables the electrical interfacing. The following devices were integrated in the prototype: OoC devices from Bi/ond and BEOnChip, a microelectrode array (MEA) device from MultiChannel Systems, and piezoelectric micropumps from Fraunhofer EMFT. In the OoC devices, cell culture was performed on integrated on-chip membranes. On the MEA, neuronal cells were cultured directly on the surface of the chip. For initial experiments, static cultures were performed to investigate the biocompatibility of all included materials inside the prototype. BEOnChip performed a static cell culture with skin cells (Ha- CaT) in their device. Normal cell viability and morphology was observed after 96 h and 21 days of culture using Calcein-AM/PI live/ dead staining. MCS performed static cell culture using hiPSCs-derived neurons directly cultured on the PLO/laminin-coated MEA chips. After 14 days of culture, eGFP staining showed normal cell morphology and network formation. Bi/ond performed an endothelial cell culture (HMEC-1), showing proper cell adhesion and viability in their devices. The biological experiments under static conditions showed normal cell morphology and viability in all integrated devices. In the next phase of the project, the full SMWP platform with integrated perfusion will be used for biological experimentation to generate an air-liquid interface with skin cells (BEOnChip), a perfusable MEA (MCS) and endothelial tube formation under unidirectional flow (Bi/ond). ...
Abstract (2023) - Sandro Meucci, B. de Wagenaar, Agnes Bußmann, Jannis Meents, Richard Klemm, Jacco Scheer, Albert van Breemen, Thiago Moura, Massimo Mastrangeli
Organs-on-Chip (OoC) have been a promise of microfluidics since their early days, leading to a widespread use in research. OoC adoption by industry conversely has so far been slow, resulting in a big gap between what is developed by elite pioneers and what can be offered to a broad audience. A way to bridge this gap is the consolidation of standards for design, manufacturing and qualification of OoC, making it easier for experts in different fields to combine their expertise and creating integrated systems with higher value than the sum of the parts. To this end, here we present the Smart Multi-Well Plate (SMWP), a device based on an open technology platform and the standardized 96-well plate format. Within this format, the SMWP integrates 16 OoC devices and piezoelectric micropumps, connected by a microfluidic network and controlled by integrated electronics. Results and discussion: The SMWP allows for high modularity, with design and interfacing rules according to guidelines defined by experts from industry and academia [1]. With the SMWP, OoC devices, sensors and piezoelectric micropumps can be integrated using industrial workflows exploiting automated pick-and-placing and wire-bonding machines. The modules are fluidically connected by means of a polymeric fluidic circuit board and electrically connected by reusable and disposable printed circuits boards. These take care of both control of micropumps and sensors and transfer of power and data to the outside world. Fluidic and electric performance of the plate, including piezoelectric micropumps from Fraunhofer EMFT, were tested in combination with barrier model OoC devices from BEOnChip and Bi/ond and multi electrode array chips from MultiChannel Systems. Preliminary results of the biological validation of the three embodiments of the SMWP will also be presented. Conclusions: An autonomous standardized OoC platform based on an open technology was realized by leveraging industrially upscalable processes and integrating OoC devices. ...
Conference paper (2021) - Gonçalo Rodrigues, Mariana Neca, Vasiliki Giagka, João Silva, Diogo Brito, Taimur Rabuske, Jorge Fernandes, Rainer Mohrlok, Christoph Jeschke, Jannis Meents, Kambiz Nanbakhsh
Active neural interfaces for bioelectronic medicine are envisioned to be mm-sized. Such miniaturization is at the moment hampered by the available wireless power techniques as well as the large volume the conventional hermetic packaging adds to the implant. Alternatively, conformal coatings are being explored for the protection of the implant electronics. Such approach has the potential to allow for the use of RF (radio-frequency) energy for powering, and miniaturization to the extreme of having a single IC (integrated circuit) as the whole implant (single chip implants). The longevity of conformal encapsulation can be assessed using accelerated soak tests in a dedicated apparatus in vitro, but these are usually not sufficient, as they fail to reveal additional failure modes that manifest themselves in vivo. Therefore, to investigate the performance of conformal coatings in vivo a compact, mm-sized wireless monitoring system is required. The development of such a system exhibits several challenges, mostly concerned with how to receive enough energy in such a small implant to power the monitoring sensor and transmit information regarding the integrity of the coating. In this paper we propose a system architecture for such a mm-sized wireless system, suitable for medium-to-Iong term monitoring of implants, by designing the whole system as a single monolithic IC. It is shown, by experiments, simulation or analytically that the identified challenges are possible to overcome, allowing to proceed towards the practical prototype. ...