In searching process for new, advanced technologies which could be applied for on-site diagnostics of machine insulation this paper discuses the application of damped AC voltages to detect and to analyze the PD processes. Based on laboratory investigation on a full scale stator i ...
This document describes application of statistical analysis to several diagnostic parameters obtained during on-site measurements on MV power cables. The goal of this analysis is to estimate statistical borders values for different diagnostic parameters related to PD phenomena fo ...
For advanced, non-destructive on-site condition monitoring of HV power cables up to 150kV by partial discharge detection and dielectric losses measurement it is necessary to energize the disconnected cable system. One of the methods available for this purpose is based on applying ...
This paper describes important aspects of PD diagnostics of distribution power cables. PD parameter were discussed under consideration of attenuation and dispersive effects of cable characteristics. Field experiences with PD diagnosis on PILC and XLPE cables by energizing with Da ...
In this contribution statistical analysis were applied to evaluate condition of serviced aged MV power cables systems. Analysis were based on large number of diagnostic data as obtained from the on-site inspections of 89 mass insulated power cables, 26 XLPE insulated power cables ...