Journal article (2024) - Aihui Fu, Aleksandra Lekić, Kyriaki Nefeli D. Malamaki, Georgios C. Kryonidis, Juan M. Mauricio, Charis S. Demoulias, Peter Palensky, Miloš Cvetković
The extensive integration of distributed renewable energy resources (DRES) can lead to several issues in power grids, particularly in distribution grids, due to their inherent intermittency. This paper presents a stochastic simulation-based approach to estimate the maximum permissible penetration level of DRES and to determine the optimal capacity of centralized battery energy storage systems (BESS) in distribution networks while adhering to technical constraints. The stochastic method creates a wide range of scenarios under various conditions. For each scenario, our proposed approach calculates the maximum allowable penetration level of DRES and the required BESS capacity with different DRES control logics. The maximum allowable penetration level of DRES and the requirements of the BESS capacity are determined by an analysis of various simulation results. This paper's unique contribution lies in equipping distribution system operators (DSOs) with the ability to compare results and select the most appropriate voltage control and power smoothing methods. This aids in mitigating challenges associated with overvoltage and intermittency issues arising from DRES-generated power, thereby enhancing the overall resilience and reliability of the power grid. Case studies that include four voltage control algorithms and three power smoothing methods demonstrate the universality and effectiveness of the proposed approach. ...

Definitions and Methodologies for Control and Sizing of Central Battery Energy Storage System

Journal article (2023) - Spyros I. Gkavanoudis, Kyriaki Nefeli D. Malamaki, Eleftherios O. Kontis, Charis S. Demoulias, Aditya Shekhar, Umer Mushtaq, Sagar Bandi Venu
The variability of the output power of distributed renewable energy sources (DRESs) that originate from the fast-changing climatic conditions can negatively affect the grid stability. Therefore, grid operators have incorporated ramp-rate limitations (RRLs) for the injected DRES power in the grid codes. As the DRES penetration levels increase, the mitigation of high-power ramps is no longer considered as a system support function but rather an ancillary service (AS). Energy storage systems (ESSs) coordinated by RR control algorithms are often applied to mitigate these power fluctuations. However, no unified definition of active power ramps, which is essential to treat the RRL as AS, currently exists. This paper assesses the various definitions for ramp-rate RR and proposes RRL method control for a central battery ESS (BESS) in distribution systems (DSs). The ultimate objective is to restrain high-power ramps at the distribution transformer level so that RRL can be traded as AS to the upstream transmission system (TS). The proposed control is based on the direct control of the ΔP/Δt, which means that the control parameters are directly correlated with the RR requirements included in the grid codes. In addition, a novel method for restoring the state of charge (SoC) within a specific range following a high ramp-up/down event is proposed. Finally, a parametric method for estimating the sizing of central BESSs (BESS sizing for short) is developed. The BESS sizing is determined by considering the RR requirements, the DRES units, and the load mix of the examined DS. The BESS sizing is directly related to the constant RR achieved using the proposed control. Finally, the proposed methodologies are validated through simulations in MATLAB/Simulink and laboratory tests in a commercially available BESS. ...