M. Bozic

info

Please Note

7 records found

Journal article (2026) - A. Arami, M. Bozic, Christal van de Steeg-Henzen, Y. Zhao, Y. Zhang, Q. Tao, Alexandru Cernicanu, Hildebrandus Johannes Lamb, S.D. Weingärtner
Purpose
To evaluate single- and dual-band pulse modules for suppressing extra-cardiac signal in cardiac MRI, and test their applicability for time-efficient imaging with reduced FOV in myocardial 𝑇2 mapping at 3 T.

Methods
Outer Volume Suppression (OVS) was implemented using two regional saturation slabs, along the phase-encoding direction. Different Amplitude-Modulated (AM) and Amplitude-Frequency-Modulated (AM-FM) pulses were explored. AM sinc and AM-FM Hyperbolic Secant (HS) pulses, as single- (S:1b and HS:1b) and dual-band (S:2b and HS:2b) versions, were chosen for full evaluation. Pulses were individually optimized for minimal residual signal and optimal suppression-band profiles. Pulse performance was assessed through simulations and phantom experiments, and evaluated in seven healthy subjects using residual signal and quantitative myocardial 𝑇2 mapping with rFOV.

Results
In simulations, optimized HS pulses demonstrated superior suppression-band profile homogeneity and 𝐵0 robustness, while both pulse classes showed comparable 𝐵+1 sensitivity. Phantom data revealed better signal suppression with HS pulses (S:1b: 19.22% ± 3.23%, S:2b: 16.85% ± 6.80%, HS:1b: 4.66% ± 1.04%, HS:2b: 2.85% ± 1.01%). The residual difference across slabs was slightly reduced using simultaneous dual-band compared with sequential single-band approaches (S:1b: 3.81% vs. S:2b: 0.92%; HS:1b: 4.56% vs. HS:2b: 0.66%). In vivo, despite significantly lower residual with HS pulses (p = 0.0015) and visually observed artifacts with sinc pulses, no significant difference in 𝑇2 was observed across all configurations (p = 0.087) in myocardial 𝑇2 mapping.

Conclusion
AM-FM pulses achieved robust suppression of extra-cardiac signals, with dual-band implementations minimizing suppression-band differences. This can enable artifact-free rFOV imaging, for improved image quality in myocardial 𝑇2
mapping. ...
Journal article (2025) - Maša Božić-Iven, Stanislas Rapacchi, Yi Zhang, Qian Tao, Lothar Rudi Schad, Sebastian Weingärtner
Purpose: To introduce Double Inversion Recovery (DIR) preparations for myocardial Arterial Spin Labeling (myoASL) for mitigation of heart rate (HR) variability induced physiological noise (PN).

Methods: DIR-labeling was implemented for double ECG-gated myoASLsequences and compared with conventional Flow-sensitive Alternating Inversion Recovery (FAIR) labeling using single inversions. In DIR-preparations, the FAIR-inversion pulses were immediately followed by an identical reinversion pulse, applied either slice-selectively or nonselectively. Bloch-equation-based simulation and phantom experiments were performed to evaluate the PN and SNR across a range of HR variabilities. Data from six healthy subjects were acquired to evaluate myocardial blood flow (MBF), PN, and SNR in vivo.

Results: Simulation experiments showed that the averageMBFvalues remained nearly constant across the range of HR variabilities and were comparable across all three sequences. However, DIR-labeling allowed for greater recovery of the myocardial background signal, which mitigates the sensitivity to HR-dependent changes in the inversion time. Consequently, PN in the presence of HR variability was substantially reduced with DIR-labeling. For HR variabilities corresponding to the mean value observed in vivo, this resulted in a simulated SNR gain of 1.79 ± 0.90 for selective and 1.55 ± 0.77 for nonselective DIR-labeling. In vivo, DIR-labeling showed reduced PN, with 53% (p < 0.05)/44% (p = 0.16) less PN compared with conventional FAIR-myoASL, leading to an average SNR gain of 1.47 ± 0.63 (p = 0.09)/1.32 ± 0.57 (p = 0.84) with selective/nonselective reinversions.

Conclusion: The proposed DIR-preparations reduce sensitivity to HR variations and alleviate PN in double ECG-gated myoASL, improving the precision of myoASL-based perfusion quantification.
...
Journal article (2025) - Maximilian Fenski, Darian Viezzer, Vy An Nguyen, Simone Hufnagel, Leonard Grassow, Maša Božić-Iven, Sebastian Weingärtner, Christoph Kolbitsch, Jeanette Schulz-Menger
To evaluate heart rate as a patient-related confounder in a commonly applied T2 balanced steady-state free precession (bSSFP) mapping sequence used for myocardial tissue characterization.Materials and Methods: This retrospective analysis included prospectively (from December 2013 to November 2021) acquired cardiac MRI (1.5 T) datasets with T2 bSSFP mapping from 69 healthy volunteers. Phantom studies and Bloch simulations were performed with heart rates of 60–130 beats per minute and different resting periods (three, six, or nine R-R intervals). Sequence parameters (repetition time, echo time, flip angle, echo train length) were matched across volunteer, phantom, and simulation measurements. Reference values covered clinically relevant T1 and T2 properties found in native myocardium (short, 1041 and 44 msec; medium, 1293 and 43 msec; long, 1534 and 40 msec). A mixed linear model assessed the effect of heart rate on T2 values in volunteer measurements.Results: The study included 69 healthy volunteers (median age, 34 years; 44 female and 25 male). Heart rate influenced T2 values acquired with three R-R resting periods (r = −0.38, P =.002; linear regression slope, −0.7 msec/10 beats per minute [95% CI: −1.2, −0.1]). In simulation and phantom measurements, T2 values acquired with three R-R resting periods strongly correlated with heart rate, irrespective of myocardial T1 and T2 properties (r ≤ −0.88; P <.01 for all measurements). Heart rate dependency was reduced with increased resting periods in simulations and phantom measurements. Short myocardial T1 and T2 values derived from T2 bSSFP with nine R-R resting periods were not dependent on heart rate (r = −0.41; P =.33).Conclusion: T2 bSSFP with three R-R resting periods underestimates T2 values with increasing heart rates. Use of longer resting periods with T2 bSSFP mapping sequences reduced heart rate dependency. ...
Journal article (2024) - Joao Tourais, M. Bozic, Mehmet Akcakaya, Y. Zhao, Q. Tao, Iain Pierce, Christian Nitsche, George D. Thornton, Lothar R. Schad, Thomas A. Treibel, S.D. Weingärtner
Purpose: Evaluate the feasibility of quantification of Relaxation Along a Fictitious Field in the 2nd rotating frame (RAFF2) relaxation times in the human myocardium at 3 T.

Methods: TRAFF2 mapping was performed using a breath-held ECG-gated acquisition of five images: one without preparation, three preceded by RAFF2 trains of varying duration, and one preceded by a saturation prepulse. Pixel-wise TRAFF2 maps were obtained after three-parameter exponential fitting. The repeatability of TRAFF2, T1, and T2 was assessed in phantom via the coefficient of variation (CV) across three repetitions. In seven healthy subjects, TRAFF2 was tested for precision, reproducibility, inter-subject variability, and image quality (IQ) on a Likert scale (1 = Nondiagnostic, 5 = Excellent). Additionally, TRAFF2 mapping was performed in three patients with suspected cardiovascular disease, comparing it to late gadolinium enhancement (LGE), native T1, T2, and ECV mapping.

Results: In phantom, TRAFF2 showed good repeatability (CV < 1.5%) while showing no (R2=0.09) and high (R2=0.99) correlation with T1 and T2, respectively. Myocardial TRAFF2 maps exhibited overall acceptable image quality (IQ = 3.0±1.0) with moderate artifact levels, stemming from off-resonances near the coronary sinus. Average TRAFF2 time across subjects and repetitions was 79.1 ± 7.3 ms. Good precision (7.6 ± 1.4%), reproducibility (1.0 ± 0.6%), and low inter-subject variability (10.0 ± 1.8%) were obtained. In patients, visual agreement of the infarcted area was observed in the TRAFF2 map and LGE.

Conclusion: Myocardial TRAFF2 quantification at 3 T was successfully achieved in a single breath-hold with acceptable image quality, albeit with residual off-resonance artifacts. Nonetheless, preliminary clinical data indicate potential sensitivity of TRAFF2 mapping to myocardial infarction detection without the need for contrast agents, but off-resonance artifacts mitigation warrants further investigation. ...

Impact of physiological and acquisition parameters

Journal article (2023) - Maša Božić-Iven, Stanislas Rapacchi, Qian Tao, Iain Pierce, George Thornton, Christian Nitsche, Thomas A. Treibel, Lothar R. Schad, Sebastian Weingärtner
Purpose: To investigate and mitigate the influence of physiological and acquisition-related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). Methods: A Flow-sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch-equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood (Formula presented.) relaxation time ((Formula presented.)) affect quantification of myoASL-MBF. In vivo myoASL-images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject-specific (Formula presented.) values and, for spGRE imaging, subtracting an additional saturation-prepared baseline from the original baseline signal. Results: Simulated and phantom experiments showed a strong dependence on AMS and FA ((Formula presented.) >0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation-baseline correction in spGRE. Only a very mild HR dependence ((Formula presented.) >0.59) was observed which was reduced when calculating MBF with individual (Formula presented.). For corrected spGRE, in vivo mean global spGRE-MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra-subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter-subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP. Conclusion: Our results show that physiological and acquisition-related factors can lead to spurious changes in myoASL-MBF if not accounted for. Using individual (Formula presented.) and a saturation-baseline can reduce these variations in spGRE and improve reproducibility of FAIR-myoASL against acquisition parameters. ...

From Theory to Practice

Review (2022) - Tevfik F. Ismail, Wendy Strugnell, Chiara Coletti, Maša Božić-Iven, Sebastian Weingärtner, Kerstin Hammernik, Teresa Correia, Thomas Küstner
Cardiovascular disease (CVD) is the leading single cause of morbidity and mortality, causing over 17. 9 million deaths worldwide per year with associated costs of over $800 billion. Improving prevention, diagnosis, and treatment of CVD is therefore a global priority. Cardiovascular magnetic resonance (CMR) has emerged as a clinically important technique for the assessment of cardiovascular anatomy, function, perfusion, and viability. However, diversity and complexity of imaging, reconstruction and analysis methods pose some limitations to the widespread use of CMR. Especially in view of recent developments in the field of machine learning that provide novel solutions to address existing problems, it is necessary to bridge the gap between the clinical and scientific communities. This review covers five essential aspects of CMR to provide a comprehensive overview ranging from CVDs to CMR pulse sequence design, acquisition protocols, motion handling, image reconstruction and quantitative analysis of the obtained data. (1) The basic MR physics of CMR is introduced. Basic pulse sequence building blocks that are commonly used in CMR imaging are presented. Sequences containing these building blocks are formed for parametric mapping and functional imaging techniques. Commonly perceived artifacts and potential countermeasures are discussed for these methods. (2) CMR methods for identifying CVDs are illustrated. Basic anatomy and functional processes are described to understand the cardiac pathologies and how they can be captured by CMR imaging. (3) The planning and conduct of a complete CMR exam which is targeted for the respective pathology is shown. Building blocks are illustrated to create an efficient and patient-centered workflow. Further strategies to cope with challenging patients are discussed. (4) Imaging acceleration and reconstruction techniques are presented that enable acquisition of spatial, temporal, and parametric dynamics of the cardiac cycle. The handling of respiratory and cardiac motion strategies as well as their integration into the reconstruction processes is showcased. (5) Recent advances on deep learning-based reconstructions for this purpose are summarized. Furthermore, an overview of novel deep learning image segmentation and analysis methods is provided with a focus on automatic, fast and reliable extraction of biomarkers and parameters of clinical relevance. ...