Koen Willemsen
Please Note
6 records found
1
Impact of MRI integration in CT-based planning on the accuracy of patient-specific 3D-printed shelf implant placement
A comparative cadaveric study
Introduction: Hip dysplasia, characterized by an insufficient acetabular coverage of the femoral head, increases hip joint stress and predisposes to degenerative changes. A novel 3D-printed, patient-specific extracapsular shelf implant was developed to increase femoral head coverage. Accurate implant placement is crucial. This cadaveric study compared CT-only surgical planning with combined CT- and MRI-based planning to evaluate whether MRI integration improves positioning accuracy. Methods: Two cohorts of non‑dysplastic cadaveric hips were studied. In cohort 1 (five hips), implant design was based solely on CT imaging. In cohort 2 (four hips), both CT and MRI datasets were used, incorporating capsular soft‑tissue anatomy. Postoperative implant positioning was compared with preoperative plans using point-cloud analyses, clockface coverage graphs, and Dice coefficients. Acceptable placement was defined as: median Euclidean distance < 5 mm, median angular deviation < 5°, and Dice > 0.75 respectively. Results: In the CT‑only cohort, three of five implants failed one or more accuracy thresholds, with Euclidean distances up to 8.5 mm, coverage deviations up to 6°, and Dice coefficients as low as 0.37. CT‑only designed implants consistently tilted away from the acetabular rim, reflecting underestimation of hip capsule thickness and insertion height. In the CT+MRI cohort, all four implants met the <5 mm and <5° deviation thresholds, and three achieved Dice ≥0.75. No consistent deviation patterns were observed. Conclusion: Combined CT and MRI planning improved implant positioning accuracy by better accounting for variations in hip capsule morphology. MRI integration demonstrated superior performance over CT‑only planning for patient‑specific shelf implant placement.
Association of osteotomy, age, and component fixation with the outcomes of total hip arthroplasty in patients with hip dysplasia
A Dutch population-based registry study
Background and purpose — Hip dysplasia can present challenges for total hip arthroplasty (THA) due to anatomic abnormalities. We aimed to assess the association of age, sex, osteotomies prior to THA, and fixation method on 5-and 10-year revision-free implant survival and patient-reported outcome measures (PROMs) of THAs in patients with hip dysplasia. Methods — Using Dutch Arthroplasty Register data, we studied hip dysplasia patients receiving primary THAs in 2007–2021 (n = 7,465). THAs were categorized by age, pelvic osteotomy prior to THA (yes/no), and fixation (cemented, uncemented, hybrid, reverse hybrid). Kaplan–Meier and multivariable Cox models were used to determine 5-and 10-year revision-free implant survival and adjusted hazard ratios including 95% confidence intervals (CIs). Reasons for revision and PROMs were compared within the categories. Results — We found a 10-year revision-free implant survival of 94.9% (CI 94.3–95.5). Patients younger than 50 years had a 10-year implant survival of 93.3% (CI 91.9– 94.7), Patients with prior pelvic osteotomy had a 10-year implant survival of 92.0% (CI 89.8–94.2). Fixation method and sex were not associated with implant survival. Patients with a prior pelvic osteotomy had more revisions due to cup loosening and reported lower PROM scores than patients without earlier osteotomy. Conclusion — 5-and 10-year revision-free implant survival rates of THA for hip dysplasia are 96.4% and 94.9%. Age and prior osteotomies were associated with decreased implant survival rates in patients with hip dysplasia, while fixation method was not. Prior osteotomies were also associated with reduced PROM scores.
For decades, the advantages of rapid prototyping for clinical use have been recognized. However, demonstrations of potential solutions to treat spinal problems that cannot be solved otherwise are scarce. In this paper, we describe the development, regulatory process, and clinical application of two types of patient specific 3D-printed devices that were developed at an in-house 3D point-of-care facility. This 3D lab made it possible to elegantly treat patients with spinal problems that could not have been treated in a conventional manner. The first device, applied in three patients, is a printed nylon drill guide, with such accuracy that it can be used for insertion of cervical pedicle screws in very young children, which has been applied even in semi-acute settings. The other is a 3D-printed titanium spinal column prosthesis that was used to treat progressive and severe deformities due to lysis of the anterior column in three patients. The unique opportunity to control size, shape, and material characteristics allowed a relatively easy solution for these patients, who were developing paraplegia. In this paper, we discuss the pathway toward the design and final application, including technical file creation for dossier building and challenges within a point-of-care lab.
BACKGROUND AND PURPOSE: The Chiari osteotomy was a regular treatment for developmental hip dysplasia before it became mostly reserved as a salvage therapy. However, the long-term survival of the Chiari osteotomy has not been systematically investigated. We investigated the survival time of the Chiari osteotomy until conversion to total hip arthroplasty (THA) in patients with primary hip dysplasia, and factors which correlated with survival, complications, and the improvement measured in radiographic parameters. PATIENTS AND METHODS: Studies were included when describing patients (> 16 years) with primary hip dysplasia treated with a Chiari osteotomy procedure with 8 years' follow-up. Data on patient characteristics, indications, complications, radiographic parameters, and survival time (endpoint: conversion to THA) were extracted. RESULTS: 8 studies were included. The average postoperative center-edge angle, acetabular head index, and Sharp angle were generally restored within the target range. 3 studies reported Kaplan-Meier survival rates varying from 96% at 10 years to 72% at 20 years' follow-up. Negative survival factors were high age at intervention and pre-existing advanced preoperative osteoarthritis. Moreover, reported complications ranged between 0% and 28.3 %. INTERPRETATION: The Chiari osteotomy has high reported survival rates and is capable of restoring radiographic hip parameters to healthy values. When carefully selected by young age, and a low osteoarthritis score, patients benefit from the Chiari osteotomy with satisfactory survival rates. The position of the Chiari osteotomy in relation to the periacetabular osteotomies should be further (re-)explored.
The concept of a novel patient-specific 3D-printed shelf implant should be evaluated in a relevant large animal model with hip dysplasia. Therefore, three dogs with radiographic bilateral hip dysplasia and a positive subluxation test underwent unilateral acetabular augmentation with a 3D-printed dog-specific titanium implant. The contralateral side served as control. The implants were designed on CT-based pelvic bone segmentations and extended the dysplastic acetabular rim to increase the weight bearing surface without impairing the range of motion. Outcome was assessed by clinical observation, manual subluxation testing, radiography, CT, and gait analysis from 6 weeks preoperatively until termination at 26 weeks postoperatively. Thereafter, all hip joints underwent histopathological examination. The implantation and recovery from surgery was uneventful. Clinical subluxation tests at the intervention side became negative. Imaging showed medialization of the femoral head at the intervention side and the mean (range) CE-angle increased from 94° (84°-99°) preoperative to 119° (117°-120°) postoperative. Gait analysis parameters returned to pre-operative levels after an average follow-up of 6 weeks. Histology showed a thickened synovial capsule between the implant and the femoral head without any evidence of additional damage to the articular cartilage compared to the control side. The surgical implantation of the 3D shelf was safe and feasible. The patient-specific 3D-printed shelf implants restored the femoral head coverage and stability of dysplastic hips without complications. The presented approach holds promise to treat residual hip dysplasia justifying future veterinary clinical trials to establish clinical effectiveness in a larger cohort to prepare for translation to human clinic.
Patient-specific 3D-printed shelf implant for the treatment of hip dysplasia
Anatomical and biomechanical outcomes in a canine model
A solution for challenging hip dysplasia surgery could be a patient-specific 3D-printed shelf implant that is positioned extra-articular and restores the dysplastic acetabular rim to normal anatomical dimensions. The anatomical correction and biomechanical stability of this concept were tested in a canine model that, like humans, also suffers from hip dysplasia. Using 3D reconstructed computed tomography images the 3D shelf implant was designed to restore the radiological dysplastic hip parameters to healthy parameters. It was tested ex vivo on three dog cadavers (six hips) with hip dysplasia. Each hip was subjected to a biomechanical subluxation test, first without and then with the 3D shelf implant in place. Subsequently, an implant failure test was performed to test the primary implant fixation. At baseline, the dysplastic hips had an average Norberg angle of 88 ± 3° and acetabular coverage of 47 ± 2% and subluxated at an average of 83 ± 2° of femoral adduction. After adding the patient-specific shelf implants the dysplastic hips had an average Norberg angle of 122 ± 2° and acetabular coverage of 67 ± 3% and subluxated at an average of 117 ± 2° of femoral adduction. Implant failure after primary implant fixation occurred at an average of 1330 ± 320 Newton. This showed that the patient-specific shelf implants significantly improved the coverage and stability of dysplastic hips in a canine model with naturally occurring hip dysplasia. The 3D shelf is a promising concept for treating residual hip dysplasia with a straightforward technology-driven approach; however, the clinical safety needs to be further investigated in an experimental proof-of-concept animal study.