TW

Tamar Wissing

info

Please Note

5 records found

Journal article (2025) - Hanneke Crielaard, Tamar B. Wissing, Su Guvenir Torun, Gert Jan Kremers, Pablo de Miguel, Ranmadusha M. Hengst, Frank J.H. Gijsen, Ali C. Akyildiz, Kim van der Heiden
Many cardiovascular events are triggered by fibrous cap rupture of an atherosclerotic plaque in arteries. However, cap rupture, including the impact of the cap's structural components, is poorly understood. To obtain better mechanistic insights in a biologically and mechanically controlled environment, we previously developed a tissue-engineered fibrous cap model. In the current study, we characterized the (local) structural and mechanical properties of these tissue-engineered cap analogs. Twenty-four collagenous cap analogs were cultured. The analogs were imaged with multiphoton microscopy with second-harmonic generation to obtain local collagen fiber orientation and dispersion. Then, the analogs were mechanically tested under uniaxial tensile loading until failure, and the local deformation (strain) and failure characteristics were analyzed. Our results demonstrated that the tissue-engineered analogs mimic the dominant (circumferential) fiber direction of human plaques. The analogs also exhibited a physiological strain stiffening response, similar to human fibrous plaque caps. Ruptures in the analogs initiated in and propagated towards local high-strain regions. The local strain values at the rupture sites were similar to the ones reported for carotid human fibrous plaque tissue. Finally, the study revealed that the rupture propagation path in the analogs followed the local fiber direction. Statement of significance: Many cardiovascular events are triggered by mechanical rupture of atherosclerotic plaque caps. Yet, cap rupture mechanics is poorly understood. This is mainly due to the scarcity of plaques for high-throughput testing and the structural complexity of plaques. To overcome this, we previously developed tissue-engineered cap analogs. The current study characterizes (local) structural and mechanical properties of these cap analogs. Our findings show that: (1) cap analogs closely mimic human fibrous caps, including fiber orientation and strain stiffening responses; (2) structural and mechanical properties of cap analogs are associated, which provides critical information for understanding plaque rupture; and (3) cap ruptures commonly start in and propagate towards high-strain areas, indicating the potential use of strain measurements for cap rupture risk assessment. ...
Review (2024) - Imke Jansen, Rachel Cahalane, Ranmadusha Hengst, Ali Akyildiz, Eric Farrell, Frank Gijsen, Elena Aikawa, Kim van der Heiden, Tamar Wissing
The rupture of an atherosclerotic plaque cap overlying a lipid pool and/or necrotic core can lead to thrombotic cardiovascular events. In essence, the rupture of the plaque cap is a mechanical event, which occurs when the local stress exceeds the local tissue strength. However, due to inter- and intra-cap heterogeneity, the resulting ultimate cap strength varies, causing proper assessment of the plaque at risk of rupture to be lacking. Important players involved in tissue strength include the load-bearing collagenous matrix, macrophages, as major promoters of extracellular matrix degradation, and microcalcifications, deposits that can exacerbate local stress, increasing tissue propensity for rupture. This review summarizes the role of these components individually in tissue mechanics, along with the interplay between them. We argue that to be able to improve risk assessment, a better understanding of the effect of these individual components, as well as their reciprocal relationships on cap mechanics, is required. Finally, we discuss potential future steps, including a holistic multidisciplinary approach, multifactorial 3D in vitro model systems, and advancements in imaging techniques. The obtained knowledge will ultimately serve as input to help diagnose, prevent, and treat atherosclerotic cap rupture. ...

Toward understanding the role of microcalcifications in plaque rupture

Journal article (2023) - Imke Jansen, Hanneke Crielaard, Tamar Wissing, Carlijn Bouten, Frank Gijsen, Ali C. Akyildiz, Eric Farrell, Kim van der Heiden
Rupture of the cap of an atherosclerotic plaque can lead to thrombotic cardiovascular events. It has been suggested, through computational models, that the presence of microcalcifications in the atherosclerotic cap can increase the risk of cap rupture. However, the experimental confirmation of this hypothesis is still lacking. In this study, we have developed a novel tissue-engineered model to mimic the atherosclerotic fibrous cap with microcalcifications and assess the impact of microcalcifications on cap mechanics. First, human carotid plaque caps were analyzed to determine the distribution, size, and density of microcalcifications in real cap tissue. Hydroxyapatite particles with features similar to real cap microcalcifications were used as microcalcification mimics. Injected clusters of hydroxyapatite particles were embedded in a fibrin gel seeded with human myofibroblasts which deposited a native-like collagenous matrix around the particles, during the 21-day culture period. Second harmonic multiphoton microscopy imaging revealed higher local collagen fiber dispersion in regions of hydroxyapatite clusters. Tissue-engineered caps with hydroxyapatite particles demonstrated lower stiffness and ultimate tensile stress than the control group samples under uniaxial tensile loading, suggesting increased rupture risk in atherosclerotic plaques with microcalcifications. This model supports previous computational findings regarding a detrimental role for microcalcifications in cap rupture risk and can further be deployed to elucidate tissue mechanics in pathologies with calcifying soft tissues. ...
Journal article (2022) - T. B. Wissing, K. Van der Heiden, S. M. Serra, A. I.P.M. Smits, C. V.C. Bouten, F. J.H. Gijsen
A significant amount of vascular thrombotic events are associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 × 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm ∅ fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of a successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general. ...
Journal article (2022) - Hanneke Crielaard, Su Guvenir Torun, Tamar B. Wissing, Pablo de Miguel Muñoz, Gert Jan Kremers, Frank J.H. Gijsen, Kim Van Der Heiden, Ali C. Akyildiz
The rupture of atherosclerotic plaques in coronary and carotid arteries is the primary cause of fatal cardiovascular events. However, the rupture mechanics of the heterogeneous, highly collagenous plaque tissue, and how this is related to the tissue's fibrous structure, are not known yet. Existing pipelines to study plaque mechanics are limited to obtaining only gross mechanical characteristics of the plaque tissue, based on the assumption of structural homogeneity of the tissue. However, fibrous plaque tissue is structurally heterogeneous, arguably mainly due to local variation in the collagen fiber architecture. The mechano-imaging pipeline described here has been developed to study the heterogeneous structural and mechanical plaque properties. In this pipeline, the tissue's local collagen architecture is characterized using multiphoton microscopy (MPM) with second-harmonic generation (SHG), and the tissue's failure behavior is characterized under uniaxial tensile testing conditions using digital image correlation (DIC) analysis. This experimental pipeline enables correlation of the local predominant angle and dispersion of collagen fiber orientation, the rupture behavior, and the strain fingerprints of the fibrous plaque tissue. The obtained knowledge is key to better understand, predict, and prevent atherosclerotic plaque rupture events. ...